Dose-Length Product to Effective Dose Conversion Factors for Common Computed Tomography Examinations Based on Canadian Clinical Experience

2013 ◽  
Vol 64 (1) ◽  
pp. 15-17 ◽  
Author(s):  
Idris A. Elbakri ◽  
Iain D.C. Kirkpatrick
2018 ◽  
Vol 11 (1) ◽  
pp. 64-74 ◽  
Author(s):  
Sigal Trattner ◽  
Sandra Halliburton ◽  
Carla M. Thompson ◽  
Yanping Xu ◽  
Anjali Chelliah ◽  
...  

2021 ◽  
Vol 11 (8) ◽  
pp. 2130-2136
Author(s):  
Ziyad Awadh Alrowaili ◽  
M. Ashari

A safe radiation dose from computed tomography (CT) is normally specified through the Computed Tomography Dose Index (CTDI) as an “effective dose.” Radiation exposure from CT is relatively high in comparison with other radiological tests. In this paper, we evaluate doses used on adult patients during typical CT scans, in Al Jouf, the northern region of Saudi Arabia. Scanning processes were taken place in different parts of the body; including the pelvis, head, abdomen, and chest. The dose indices were calculated using the CT-expo v2.5 computer software. A comparison of the results with similar investigations, regionally and globally, was made. Other comparisons between displayed and calculated dose indices were also performed. The main values of CT volume are the dose index (CTDIvol) and dose-length product (DLP). The effectiveness results for head CTs were 45.0 mGy, 488 mGy.cm, and 5.2 mSv; while for pelvic CTs they were 16.4 mGy, 391 mGy.cm, and 4.0 mSv; whereas for abdominal CTs they were 22.2 mGy, 613 mGy.cm, and 6.5 mSv; finally they were 17.5 mGy, 380 mGy.cm, and 3.9 mSv for chest CTs. It is confirmed that the values obtained are within the internationally accepted values, except for the values of the head examination, in which the effective dose value of 5.2 mSv was higher than the recommended value. This work gives an overview of the doses received by adult patients during regular CT examination. It is the first regional CT dose survey and provides a baseline for improvement and quality control in the region of Al Jouf.


Author(s):  
Yusuke Inoue ◽  
Yuka Yonekura ◽  
Kazunori Nagahara ◽  
Ayuka Uehara ◽  
Hideki Ikuma

Abstract For radiation dose assessement of computed tomography (CT), effective dose (ED) is often estimated by multiplying the dose-length product (DLP), provided automatically by the CT scanner, by a conversion factor. We investigated such conversion in CT venography of the lower extremities performed in conjunction with CT pulmonary angiography. The study subjects consisted of eight groups imaged using different scanners and different imaging conditions (five and three groups for the GE and Siemens scanners, respectively). Each group included 10 men and 10 women. The scan range was divided into four anatomical regions (trunk, proximal thigh, knee and distal leg), and DLP was calculated for each region (regional DLP). Regional DLP was multiplied by a conversion factor for the respective region, to convert it to ED. The sum of the ED values for the four regions was obtained as standard ED. Additionally, the sum of the four regional DLP values, an approximate of the scanner-derived DLP, was multiplied by the conversion factor for the trunk (0.015 mSv/mGy/cm), as a simplified method to obtain ED. When using the simplified method, ED was overestimated by 32.3%−70.2% and 56.5%−66.2% for the GE and Siemens scanners, respectively. The degree of overestimation was positively and closely correlated with the contribution of the middle and distal portions of the lower extremities to total radiation exposure. ED/DLP averaged within each group, corresponding to the conversion factor, was 0.0089−0.0114 and 0.0091−0.0096 mSv/mGy/cm for the GE and Siemens scanners, respectively. In CT venography of the lower extremities, ED is greatly overestimated by multiplying the scanner-derived DLP by the conversion factor for the trunk. The degree of overestimation varies widely depending on the imaging conditions. It is recommended to divide the scan range and calculate ED as a sum of regional ED values.


Sign in / Sign up

Export Citation Format

Share Document