scholarly journals Estimation of effective dose using the dose length product in chest computed tomography procedures

2021 ◽  
Vol 19 (4) ◽  
pp. 979-986
Author(s):  
N. Mpumelelo ◽  
2014 ◽  
Vol 4 ◽  
pp. 38 ◽  
Author(s):  
Lukas Ebner ◽  
Felix Knobloch ◽  
Adrian Huber ◽  
Julia Landau ◽  
Daniel Ott ◽  
...  

Objective: The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. Materials and Methods: 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. Results: Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. Conclusion: The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.


2021 ◽  
Vol 11 (8) ◽  
pp. 2130-2136
Author(s):  
Ziyad Awadh Alrowaili ◽  
M. Ashari

A safe radiation dose from computed tomography (CT) is normally specified through the Computed Tomography Dose Index (CTDI) as an “effective dose.” Radiation exposure from CT is relatively high in comparison with other radiological tests. In this paper, we evaluate doses used on adult patients during typical CT scans, in Al Jouf, the northern region of Saudi Arabia. Scanning processes were taken place in different parts of the body; including the pelvis, head, abdomen, and chest. The dose indices were calculated using the CT-expo v2.5 computer software. A comparison of the results with similar investigations, regionally and globally, was made. Other comparisons between displayed and calculated dose indices were also performed. The main values of CT volume are the dose index (CTDIvol) and dose-length product (DLP). The effectiveness results for head CTs were 45.0 mGy, 488 mGy.cm, and 5.2 mSv; while for pelvic CTs they were 16.4 mGy, 391 mGy.cm, and 4.0 mSv; whereas for abdominal CTs they were 22.2 mGy, 613 mGy.cm, and 6.5 mSv; finally they were 17.5 mGy, 380 mGy.cm, and 3.9 mSv for chest CTs. It is confirmed that the values obtained are within the internationally accepted values, except for the values of the head examination, in which the effective dose value of 5.2 mSv was higher than the recommended value. This work gives an overview of the doses received by adult patients during regular CT examination. It is the first regional CT dose survey and provides a baseline for improvement and quality control in the region of Al Jouf.


Author(s):  
Yusuke Inoue ◽  
Yuka Yonekura ◽  
Kazunori Nagahara ◽  
Ayuka Uehara ◽  
Hideki Ikuma

Abstract For radiation dose assessement of computed tomography (CT), effective dose (ED) is often estimated by multiplying the dose-length product (DLP), provided automatically by the CT scanner, by a conversion factor. We investigated such conversion in CT venography of the lower extremities performed in conjunction with CT pulmonary angiography. The study subjects consisted of eight groups imaged using different scanners and different imaging conditions (five and three groups for the GE and Siemens scanners, respectively). Each group included 10 men and 10 women. The scan range was divided into four anatomical regions (trunk, proximal thigh, knee and distal leg), and DLP was calculated for each region (regional DLP). Regional DLP was multiplied by a conversion factor for the respective region, to convert it to ED. The sum of the ED values for the four regions was obtained as standard ED. Additionally, the sum of the four regional DLP values, an approximate of the scanner-derived DLP, was multiplied by the conversion factor for the trunk (0.015 mSv/mGy/cm), as a simplified method to obtain ED. When using the simplified method, ED was overestimated by 32.3%−70.2% and 56.5%−66.2% for the GE and Siemens scanners, respectively. The degree of overestimation was positively and closely correlated with the contribution of the middle and distal portions of the lower extremities to total radiation exposure. ED/DLP averaged within each group, corresponding to the conversion factor, was 0.0089−0.0114 and 0.0091−0.0096 mSv/mGy/cm for the GE and Siemens scanners, respectively. In CT venography of the lower extremities, ED is greatly overestimated by multiplying the scanner-derived DLP by the conversion factor for the trunk. The degree of overestimation varies widely depending on the imaging conditions. It is recommended to divide the scan range and calculate ED as a sum of regional ED values.


Author(s):  
T. A. Sackey ◽  
C. Schandorf ◽  
J. J. Fletcher ◽  
Y. B. Mensah ◽  
I. Shirazu ◽  
...  

The aim of this study is to estimate the effective dose and assess the lifetime attributable risk of cancer incidence of patients undergoing computed tomography scan at the Korle-Bu Teaching Hospital in the Greater Accra Region of Ghana. Data on Volume CT Dose Index ( ) and Dose Length Product ( ) displayed on the scanner control console was recorded after confirmation of the results by performing independent checks on a phantom. The effective doses were estimated using the  displayed and the anatomic region specific conversion factors ( ). The average effective dose for the head, abdomen, chest, neck, and pelvis were 3.63± 2.39mSv, 15.37±8.49 mSv, 12.72 ± 13.97 mSv, 4.04 ± 1.47 mSv and 15.8 ± 3.59 mSv respectively. Effective doses for the head and neck were within the typical range of (1-10mSv) for CT examinations whilst abdomen, chest and pelvis were above 10mSv. The average life attributable risk of cancer incidence for each region of examination were determined from the effective dose, sex and age using  the model proposed in BEIR VII Report . The average cancer risk incidence for head, neck, chest, abdomen and pelvis examinations were low in the range 1 in 10,000 to 1 in 1,000. There were wide variations in the effective dose values obtained for the same region under examination. This trend calls for the optimization of CT examination protocols to be established to ensure that patient doses are as low as reasonably achievable, economic and social factors being taken into account especially for chest examinations.


2018 ◽  
Vol 59 (10) ◽  
pp. 1247-1253 ◽  
Author(s):  
Paola Maria Cannaò ◽  
Francesco Secchi ◽  
Marco Alì ◽  
Ida Daniela D'Angelo ◽  
Marco Scarabello ◽  
...  

Background Cardiovascular computed tomography (CCT) technology is rapidly advancing allowing to perform good quality examinations with a radiation dose as low as 1.2 mSv. However, latest generation scanners are not available in all centers. Purpose To estimate radiation dose and image quality in pediatric CCT using a standard 64-slice scanner. Material and Methods A total of 100 patients aged 6.9 ± 5.4 years (mean ± standard deviation) who underwent a 64-slice CCT scan using 80, 100, or 120 kVp, were retrospectively evaluated. Radiation effective dose was calculated on the basis of the dose length product. Two independent readers assessed the image quality through signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and a qualitative score (3 = very good, 2 = good, 1 = poor). Non-parametric tests were used. Results Fifty-five exams were not electrocardiographically (ECG) triggered, 20 had a prospective ECG triggering, and 25 had retrospective ECG triggering. The median effective dose was 1.3 mSv (interquartile range [IQR] = 0.8–2.7 mSv). Median SNR was 30.6 (IQR = 23.4–33.6) at 120 kVp, 29.4 (IQR = 23.7–34.8) at 100 kVp, and 24.7 (IQR = 19.4–34.3) at 80 kVp. Median CNR was 21.0 (IQR = 14.8–24.4), 19.1 (IQR = 15.6–23.9), and 25.3 (IQR = 19.4–33.4), respectively. Image quality was very good, good, and poor in 56, 39, and 5 patients, respectively. No significant differences were found among voltage groups for SNR ( P = 0.486), CNR ( P = 0.336), and subjective image quality ( P = 0.296). The inter-observer reproducibility was almost perfect (κ = 0.880). Conclusion High-quality pediatric CCT can be performed using a 64-slice scanner, with a radiation effective dose close to 2 mSv in about 50% of the cases.