scholarly journals Correction to Conflict of Interest Statement in: POINT: Should Radiation Dose From CT Scans Be a Factor in Patient Care? Yes.

CHEST Journal ◽  
2017 ◽  
Vol 151 (5) ◽  
pp. 1197
Radiology ◽  
2004 ◽  
Vol 231 (2) ◽  
pp. 393-398 ◽  
Author(s):  
Christoph I. Lee ◽  
Andrew H. Haims ◽  
Edward P. Monico ◽  
James A. Brink ◽  
Howard P. Forman

Author(s):  
Jwalant S. Mehta ◽  
Kirsten Hodgson ◽  
Lu Yiping ◽  
James Swee Beng Kho ◽  
Ravindra Thimmaiah ◽  
...  

Aims To benchmark the radiation dose to patients during the course of treatment for a spinal deformity. Methods Our radiation dose database identified 25,745 exposures of 6,017 children (under 18 years of age) and adults treated for a spinal deformity between 1 January 2008 and 31 December 2016. Patients were divided into surgical (974 patients) and non-surgical (5,043 patients) cohorts. We documented the number and doses of ionizing radiation imaging events (radiographs, CT scans, or intraoperative fluoroscopy) for each patient. All the doses for plain radiographs, CT scans, and intraoperative fluoroscopy were combined into a single effective dose by a medical physicist (milliSivert (mSv)). Results There were more ionizing radiation-based imaging events and higher radiation dose exposures in the surgical group than in the non-surgical group (p < 0.001). The difference in effective dose for children between the surgical and non-surgical groups was statistically significant, the surgical group being significantly higher (p < 0.001). This led to a higher estimated risk of cancer induction for the surgical group (1:222 surgical vs 1:1,418 non-surgical). However, the dose difference for adults was not statistically different between the surgical and non-surgical groups. In all cases the effective dose received by all cohorts was significantly higher than that from exposure to natural background radiation. Conclusion The treatment of spinal deformity is radiation-heavy. The dose exposure is several times higher when surgical treatment is undertaken. Clinicians should be aware of this and review their practices in order to reduce the radiation dose where possible.


Author(s):  
Visakh T ◽  
Suresh Sukumar ◽  
Abhimanyu Pradhan

Objective: The objective of this study was to estimate the entrance surface radiation dose to the thyroid region in a computed tomography (CT) brain scan.Methods: Unfors Multi-O-Meter equipment was used to measure the entrance surface at the thyroid region of adult patients ranging from 18 to 70 years of age. A total of 115 patients were included in the study based on convenience sampling. The Multi-O-Meter was kept at the thyroid region during the scan, and the values for entrance surface dose (ESD) were noted from its monitor after the scan was complete.Results: The obtained data were analyzed and violate normal distribution; therefore, the median and quartiles were computed. The overall median (Q1, Q2), ESD of the patients, was 1.335 (1.213, 1.529) mGy. The minimum and maximum dose values recorded were 1.015 mGy and 1.964 mGy, respectively.Conclusions: The result showed a significant amount of entrance surface radiation dose to the thyroid region while taking a brain scan. This data can be used for optimization of radiation protection while undergoing CT scans of brain to reduce exposure to thyroid region.


Sign in / Sign up

Export Citation Format

Share Document