Biomechanical comparison of an interspinous fusion device and bilateral pedicle screw system as additional fixation for lateral lumbar interbody fusion

2015 ◽  
Vol 30 (2) ◽  
pp. 205-210 ◽  
Author(s):  
James J. Doulgeris ◽  
Kamran Aghayev ◽  
Sabrina A. Gonzalez-Blohm ◽  
William E. Lee ◽  
Frank D. Vrionis
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Oujie Lai ◽  
Yunlin Chen ◽  
Qixin Chen ◽  
Yong Hu ◽  
Weihu Ma

Abstract Background This study was to evaluate and compare the biomechanical features of multilevel lateral lumbar interbody fusion (LLIF) with or without supplemental instrumentations. Methods Six human lumbar specimens were tested under multidirectional nondestructive moments (7.5 N·m), with a 6 degree-of-freedom spine simulator. The overall and intervertebral range of motion (ROM) were measured optoelectronically. Each specimen was tested under the following conditions at L2–5 levels: intact; stand-alone; cage supplemented with lateral plate (LP); cage supplemented with unilateral or bilateral pedicle screw/rod (UPS or BPS). Results Compared with intact condition, the overall and intersegmental ROM were significantly reduced after multilevel stand-alone LLIF. The ROM was further reduced after using LP instrumentation. In flexion-extension (FE) and axial rotation (AR), pedicle screw/rod demonstrated greater overall ROM reduction compared to LP (P < 0.01), and bilateral greater than unilateral (P < 0.01). In lateral bending (LB), BPS demonstrated greater overall ROM reduction compared to UPS and LP (P < 0.01), however, UPS and LP showed similar reduction (P = 0.245). Intervertebral ROM reductions showed similar trend as the overall ones after using different types of instrumentation. However, at L2/3 (P = 0.57) and L3/4 (P = 0.097) levels, the intervertebral ROM reductions in AR were similar between UPS and LP. Conclusions The overall and intervertebral stability increased significantly after multilevel LLIF with or without supplemental instrumentation. BPS provided the greatest stability, followed by UPS and LP. However, in clinical practice, less invasive adjunctive fixation methods including UPS and LP may provide sufficient biomechanical stability for multilevel LLIF.


2021 ◽  
Author(s):  
Masanari Takami ◽  
Ryo Taiji ◽  
Motohiro Okada ◽  
Akihito Minamide ◽  
Hiroshi Hashizume ◽  
...  

Abstract Background: Utilization of a cage with a large footprint in lateral lumbar interbody fusion (LLIF) for the treatment of spondylolisthesis leads to a high fusion rate and neurological improvement owing to the indirect decompression effect and excellent alignment correction. However, if an interbody space is too narrow for insertion of an LLIF cage for cases of spondylolisthesis of Meyerding grade II or higher, LLIF cannot be used. Therefore, we developed a novel strategy, LLIF after reduction by the percutaneous pedicle screw (PPS) insertion system in the lateral position (LIFARL), for surgeons to perform accurate and safe LLIF with PPS in patients with such pathology. This study aimed to introduce the new surgical strategy and to present preliminary clinical and radiological results of patients with spondylolisthesis of Meyerding grade II.Methods: Six consecutive patients (four men and two women; mean age, 72.7 years-old; mean follow-up period, 15.3 months) with L4 spondylolisthesis of Meyerding grade II were included. Regarding the surgical procedure, first, PPSs were inserted into the L4 and L5 vertebrae fluoroscopically, and both rods were placed in the lateral position. The L5 set screws were fixed tightly, and the L4 side of the rod was floated. Second, the L4 vertebra was reduced by fastening the L4 set screws so that they expanded the anteroposterior width of the interbody space. At that time, the L4 set screws were not fully tightened to the rods to prevent the endplate injury. Finally, the LLIF procedure was started. After inserting the cage, a compression force was added to the PPSs, and the L4 set screws were completely fastened. Results: The mean operative time was 183 min, and the mean blood loss was 90.8 mL. All cages were positioned properly. Visual analog scale score and Oswestry disability index improved postoperatively. Bone union was observed using computed tomography 12 months after surgery.Conclusion: For cases with difficulty in LLIF cage insertion for Meyerding grade II spondylolisthesis due to the narrow anteroposterior width of interbody space, LIFARL is an option to achieve LLIF combined with posterior PPS accurately and safely.Trial registration: UMIN-Clinical Trials Registry, UMIN000040268, Registered 29 April 2020, https://upload.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000045938


2020 ◽  
Author(s):  
Masanari Takami ◽  
Ryo Taiji ◽  
Motohiro Okada ◽  
Akihito Minamide ◽  
Hiroshi Hashizume ◽  
...  

Abstract Background:Utilization of a cage with a large footprint in lateral lumbar interbody fusion(LLIF) for the treatment of spondylolisthesisleads to a high fusion rate and neurological improvement owing to the indirect decompression effect and excellent alignment correction. However, if an interbody space is too narrow for insertion of an LLIF cage for cases of spondylolisthesis of Meyerding grade II or higher, LLIF cannot be used. Therefore, we developed a novel strategy, LLIF after reduction by the percutaneous pedicle screw (PPS) insertion system in the lateral position (LIFARL), for surgeons to perform accurate and safe LLIF with PPS in patients with such pathology. This study aimed to introduce the new surgical strategy and to present preliminary clinical and radiological resultsof patients with spondylolisthesis of Meyerding grade II.Methods:Six consecutive patients (four men and two women; mean age, 72.7 years-old; mean follow-up period, 12.3 months) with L4 spondylolisthesis of Meyerding grade II were included. Regarding the surgical procedure, first, PPSs were inserted into the L4 and L5 vertebrae fluoroscopically, and both rodswere placed in the lateral position. The L5 set screws were fixed tightly, and the L4 side of the rod was floated. Second, the L4 vertebra was reduced by fastening the L4 set screws sothat they expanded the anteroposterior width of the interbody space.At that time, the L4 set screws were not fully tightened to the rods to prevent the endplate injury. Finally, the LLIF procedure was started. After inserting the cage, a compression force was added to the PPSs, and the L4 set screws were completely fastened. Results:The mean operative time was 183 min, and the mean blood loss was 90.8 mL. All cages were positioned properly. Visual analog scale score and Oswestry disability index improved postoperatively. Bone union was observed in all four patients who could be followed up for more than 12 months.Conclusion:For cases with difficulty in LLIF cage insertion for Meyerding grade II spondylolisthesis due tothe narrow anteroposterior width of interbody space, LIFARL is an option to achieve LLIF combined with posterior PPS accurately and safely.Trial registration:UMIN-Clinical Trials Registry, UMIN000040268,Registered 29 April 2020,https://upload.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000045938