A dynamic interaction mass transfer model for simulating the mass transfer process in extraction columns

2006 ◽  
Vol 30 (6-7) ◽  
pp. 978-988 ◽  
Author(s):  
Xiaojin Tang ◽  
Guangshen Luo ◽  
Hongbo Li ◽  
Jiading Wang
2016 ◽  
Vol 51 (8) ◽  
pp. 1073-1085 ◽  
Author(s):  
Huanbo Cheng ◽  
Jie Zhang ◽  
Haihong Huang ◽  
Zhifeng Liu

It is critical to study the mass transfer of supercritical fluid degradation for carbon fiber composites to investigate their degradation mechanism, design the reactor, and develop recycling processes. The mass transfer process of supercritical fluid degradation was described from two aspects: mass diffusion from outside to inside, and from inside to outside. Mass transfer model of supercritical fluid degradation was established based on a proposed concentric cylindrical representative volume element. The reaction kinetic parameters were incorporated into the mass transfer equation, and the concentration distribution of supercritical fluid, mass transfer rate, reaction order, and reaction rate constant during the carbon fiber composites degradation process were calculated. Relaxation time was incorporated into the mass transfer process, and the supercritical fluid concentration calculation method considering non-Fick effect was proposed. Finally, two pretreatment methods were adopted to speed up the mass transfer process.


Author(s):  
Guodong Wang ◽  
Zhe Wang

The AP1000 containment model has been developed by using WGOTHIC version 4.2 code. Condensation heat and mass transfer from the volumes to the containment shell, conduction through the shell, and evaporation from the shell to the riser were all calculated by using the special CLIMEs model. In this paper, the latest GOTHIC version 8.0 code is used to model both condensation and evaporation heat and mass transfer process. An improved heat and mass transfer model, the diffusion layer model (DLM), is adopted to model the condensation on the inside wall of containment. The Film heat transfer coefficient option is used to model the evaporation on the outside wall of containment. As a preliminary code consolidation effort, it is possible to use GOTHIC 8.0 code as a tool to analysis the AP1000 containment response.


2011 ◽  
Vol 236-238 ◽  
pp. 789-794
Author(s):  
Ying Liu ◽  
Nai Shuai Wang ◽  
Zhi Wen ◽  
Guo Feng Lou

In this paper, a mathematical model is established to simulate heat and mass transfer process among the thin material layer consisting of zinc-containing pellets while being reduced in Rotary Heath Furnace (RHF). The material layer model is based on a single pellet model, coupling heat and mass transfer and chemical reactions. The model essentially involved solving the unsteady-state equations with appropriate initial and boundary conditions using the control volume formulation. Temperature distribution, gas phase concentration, metallization rate, and dezincing rate have been obtained and discussed.


2012 ◽  
Vol 9 (1) ◽  
pp. 91-93
Author(s):  
U.R. Ilyasov ◽  
A.V. Dolgushev

The problem of volumetric thermal action on a moist porous medium is considered. Numerical solution, the influence of fluid mobility on the dynamics of the heat and mass transfer process is analyzed. It is established that fluid mobility leads to a softer drying regime. It is shown that in low-permeability media, the fluid can be assumed to be stationary.


Author(s):  
Qing-Qing Duan ◽  
Zhi-Guo Yuan ◽  
You-Zhi Liu ◽  
Shan-Shan Duan ◽  
Xi-Fan Duan

Sign in / Sign up

Export Citation Format

Share Document