Review of 10 years research on building energy performance gap: Life-cycle and stakeholder perspectives

2018 ◽  
Vol 178 ◽  
pp. 165-181 ◽  
Author(s):  
Patrick X.W. Zou ◽  
Xiaoxiao Xu ◽  
Jay Sanjayan ◽  
Jiayuan Wang
2020 ◽  
Vol 12 (16) ◽  
pp. 6372
Author(s):  
Christine Eon ◽  
Jessica K. Breadsell ◽  
Joshua Byrne ◽  
Gregory M. Morrison

Energy efficient buildings are viewed as one of the solutions to reduce carbon emissions from the built environment. However, studies worldwide indicate that there is a significant gap between building energy targets (as-designed) and the actual measured building energy consumption (as-built). Several underlying causes for the energy performance gap have been identified at all stages of the building life cycle. Focus is generally on the post-occupancy stage of the building life cycle. However, issues relating to the construction and commissioning stages of the building are a major concern, though not usually researched. There is uncertainty on how to address the as-designed versus as-built gap. The objective of this review article is to identify causes for the energy performance gap in buildings in relation to the post-design and pre-occupancy stages and review proposed solutions. The methodology applied in this research is the rapid review, which is a variant of the systematic literature review method. Findings suggest that causes for discrepancies between as-designed and as-built energy performance during the construction and commissioning stages relate to a lack of knowledge and skills, lack of communication between stakeholders and a lack of accountability for building performance post-occupancy. Recommendations to close this gap during this period include better training, improved communication standards, collaboration, energy evaluations based on post-occupancy performance, transparency of building performance, improved testing and verification and reviewed building standards.


2021 ◽  
Vol 6 ◽  
Author(s):  
Mario Frei ◽  
Chirag Deb ◽  
Zoltan Nagy ◽  
Illias Hischier ◽  
Arno Schlueter

In the building and construction sector, the mismatch between predicted and measured energy consumption is a well-known phenomenon called the performance gap. A promising approach to reduce the performance gap and thus improve the current building energy performance assessments are methods based on in-situ measurements. In this work, we present a building assessment process based on a novel, easily deployable wireless sensor kit. The basic sensor kit for building energy assessment presented in this study consists of a heating energy input node, several indoor temperature nodes, an outdoor temperature node, and a heat flux sensor. Specifically, the study outlines a medium-scale deployment of the sensor kit in eight occupied single-family homes in Switzerland and identifies the benefits of such an approach in the estimation of the overall heat loss coefficient and U-values. The findings of this study suggest that such sensor kits could be effectively used for rapid building performance assessment, and the paper concludes by outlining the potential benefits and implementation challenges of a larger scale study.


2020 ◽  
Vol 224 ◽  
pp. 110271
Author(s):  
Nishesh Jain ◽  
Esfand Burman ◽  
Samuel Stamp ◽  
Dejan Mumovic ◽  
Michael Davies

Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3455
Author(s):  
Aleksandar S. Anđelković ◽  
Miroslav Kljajić ◽  
Dušan Macura ◽  
Vladimir Munćan ◽  
Igor Mujan ◽  
...  

A building energy performance gap can be illustrated as the difference between the theoretical (methodologically defined) and the actual energy consumption. In EU countries, Energy Performance Certificates are issued when buildings are constructed, sold, or leased. This information is the first step in order to evaluate the energy performance of the building stock. In Serbia, when issuing an energy certificate, the adopted national methodology recognizes only energy consumption for heating. The main purpose of this paper is to evaluate the energy gap and estimate the relevance of an Energy Performance Certificate to meet the national energy efficiency or carbon target. An Energy Performance Certificate determines the theoretical residential and commercial building energy efficiency or its “design intent”. This research stresses the necessity of measuring and achieving reductions in actual energy consumption through system regulation and consumers’ self-awareness in buildings. The research compares the performance of the building stock (135) that is connected to the District Heating System (DHS), with its own integrated heat meter, to Individual Gas Boiler (IGB) systems (18), in the city of Novi Sad, Serbia, built after 2014. For the purpose of comparing energy consumption, 16 buildings were selected that are very similar in terms of design, operation, and location. The data used are derived from metered consumption data, official evidence of city service companies, and Energy Performance Certificates of the considered buildings. We have determined that IGB systems have a much wider specific annual performance gap (11.19–101 kWh/m2a) than the buildings in the DHS (3.16–18.58 kWh/m2a).


2015 ◽  
Vol 43 (6) ◽  
pp. 750-763 ◽  
Author(s):  
Laura E. Fedoruk ◽  
Raymond J. Cole ◽  
John B. Robinson ◽  
Alberto Cayuela

Sign in / Sign up

Export Citation Format

Share Document