Patient safety features are more present in larger primary care practices

Health Policy ◽  
2010 ◽  
Vol 97 (1) ◽  
pp. 87-91 ◽  
Author(s):  
Sander Gaal ◽  
Pieter van den Hombergh ◽  
Wim Verstappen ◽  
Michel Wensing
2015 ◽  
Vol 06 (01) ◽  
pp. 136-147 ◽  
Author(s):  
D. Gans ◽  
J. White ◽  
R. Nath ◽  
J. Pohl ◽  
C. Tanner

Summary Background: The role of electronic health records (EHR) in enhancing patient safety, while substantiated in many studies, is still debated. Objective: This paper examines early EHR adopters in primary care to understand the extent to which EHR implementation is associated with the workflows, policies and practices that promote patient safety, as compared to practices with paper records. Early adoption is defined as those who were using EHR prior to implementation of the Meaningful Use program. Methods: We utilized the Physician Practice Patient Safety Assessment (PPPSA) to compare primary care practices with fully implemented EHR to those utilizing paper records. The PPPSA measures the extent of adoption of patient safety practices in the domains: medication management, handoffs and transition, personnel qualifications and competencies, practice management and culture, and patient communication. Results: Data from 209 primary care practices responding between 2006–2010 were included in the analysis: 117 practices used paper medical records and 92 used an EHR. Results showed that, within all domains, EHR settings showed significantly higher rates of having workflows, policies and practices that promote patient safety than paper record settings. While these results were expected in the area of medication management, EHR use was also associated with adoption of patient safety practices in areas in which the researchers had no a priori expectations of association. Conclusions: Sociotechnical models of EHR use point to complex interactions between technology and other aspects of the environment related to human resources, workflow, policy, culture, among others. This study identifies that among primary care practices in the national PPPSA database, having an EHR was strongly empirically associated with the workflow, policy, communication and cultural practices recommended for safe patient care in ambulatory settings. Citation: Tanner C, Gans D, White J, Nath R, Pohl J. Electronic health records and patient safety – co-occurrence of early EHR implementation with patient safety practices in primary care settings. Appl Clin Inf 2015; 6: 136–147http://dx.doi.org/10.4338/ACI-2014-11-RA-0099


2013 ◽  
Vol 25 (8) ◽  
pp. 415-418
Author(s):  
Joanne M. Pohl ◽  
Radhika Nath ◽  
Kai Zheng ◽  
Fred Rachman ◽  
David N. Gans ◽  
...  

2018 ◽  
Vol 28 (5) ◽  
pp. 389-396 ◽  
Author(s):  
Sally J Giles ◽  
Sahdia Parveen ◽  
Andrea L Hernan

BackgroundThe Primary Care Patient Measure of Safety (PC PMOS) is designed to capture patient feedback about the contributing factors to patient safety incidents in primary care. It required further reliability and validity testing to produce a robust tool intended to improve safety in practice.Method490 adult patients in nine primary care practices in Greater Manchester, UK, completed the PC PMOS. Practice staff (n = 81) completed a survey on patient safety culture to assess convergent validity. Confirmatory factor analysis (CFA) assessed the construct validity and internal reliability of the PC PMOS domains and items. A multivariate analysis of variance was conducted to assess discriminant validity, and Spearman correlation was conducted to establish test–retest reliability.ResultsInitial CFA results showed data did not fit the model well (a chi-square to df ratio (CMIN/DF) = 5.68; goodness-of-fit index (GFI) = 0.61, CFI = 0.57, SRMR = 0.13 and root mean square error of approximation (RMSEA) = 0.10). On the basis of large modification indices (>10), standardised residuals >± 2.58 and assessment of item content; 22 items were removed. This revised nine-factor model (28 items) was found to fit the data satisfactorily (CMIN/DF = 2.51; GFI = 0.87, CFI = 0.91, SRMR = 0.04 and RMSEA = 0.05). New factors demonstrated good internal reliability with average inter-item correlations ranging from 0.20 to 0.70. The PC PMOS demonstrated good discriminant validity between primary care practices (F = 2.64, df = 72, p < 0.001) and showed some association with practice staff safety score (convergent validity) but failed to reach statistical significance (r = −0.64, k = 9, p = 0.06).ConclusionThis study led to a reliable and valid 28-item PC PMOS. It could enhance or complement current data collection methods used in primary care to identify and prevent error.


Sign in / Sign up

Export Citation Format

Share Document