scholarly journals Incidental left anterior descending coronary artery to pulmonary artery fistula in myxomatous mitral valve prolapse

2016 ◽  
Vol 68 ◽  
pp. S88-S89
Author(s):  
Pankaj Aggarwal ◽  
Anil Bhan
Angiology ◽  
1978 ◽  
Vol 29 (5) ◽  
pp. 418-421
Author(s):  
Philippe Reyns ◽  
Haim Bartall ◽  
Alberto Benchimol ◽  
Kenneth B. Desser

2021 ◽  
Vol 13 (2) ◽  
pp. 176-178
Author(s):  
Manish Jawarkar ◽  
Pratik Manek ◽  
Mausam Shah ◽  
Vivek Wadhawa ◽  
Chirag Doshi ◽  
...  

Coronary to pulmonary artery fistula is a rare form of congenital coronary artery anomaly. Majority of coronary arteriovenous fistula detected incidentally on coronary angiography. Although, most of these patients are asymptomatic, larger fistulae can produce symptoms of heart failure. Here we present a rare case of 61-year-old female who presented primarily for mitral valve replacement for severe mitral stenosis. On screening angiography, there were two fistula arising from both right and left coronary artery and draining in to the main pulmonary artery. The patient was operated and mitral valve replacement with closure of the fistula. Patient had an uneventful post-operative period and was discharged on 7 the post-operative day.


2009 ◽  
Vol 36 (2) ◽  
pp. 244-249 ◽  
Author(s):  
Walid Ben Ali ◽  
Olivier Metton ◽  
François Roubertie ◽  
Philippe Pouard ◽  
Daniel Sidi ◽  
...  

2020 ◽  
Vol 3 (1) ◽  
Author(s):  
Mithun Nambiar ◽  
Julian Maingard ◽  
Kenny Li ◽  
Lee-Anne Slater ◽  
Ronil V. Chandra ◽  
...  

Abstract Background Management of coronary artery fistula (CAF) is based on obliterating the fistula communication between the cardiac arteries and other thoracic vessels. Case presentation We describe the presentation of an 85-year-old female with progressive exertional dyspnea on a background of a long standing left anterior descending diagonal to pulmonary artery fistula. We utilized neuro-interventional techniques to perform coil embolization via use of a Scepter XC dual lumen micro catheter. Conclusions Dual lumen balloon catheters allow for super-selective artery interrogation, stability of balloon positioning, with less trauma to vessel architecture and accurate embolization. There were no complications and the patient reported improvement of symptoms on review.


Cardiology ◽  
1979 ◽  
Vol 64 (1) ◽  
pp. 48-57 ◽  
Author(s):  
Fulvío Pileggi ◽  
Paulo Roberto Camargo ◽  
Egas Armelin ◽  
Giovanni Bellotti ◽  
Protásio da Luz ◽  
...  

Circulation ◽  
1972 ◽  
Vol 46 (5) ◽  
pp. 1005-1012 ◽  
Author(s):  
EHUD KRONGRAD ◽  
DONALD G. RITTER ◽  
ANTHONY HAWE ◽  
OWINGS W. KINCAID ◽  
DWIGHT C. MCGOON

2007 ◽  
Vol 5 (1) ◽  
Author(s):  
Ilaria Quatrini ◽  
Valerio Zacà ◽  
Sergio Mondillo

Sign in / Sign up

Export Citation Format

Share Document