Mitral valve replacement therapy causes higher 30-day postoperative mortality than mitral valvuloplasty in patients with severe ischemic mitral regurgitation: A meta-analysis of 12 studies

2015 ◽  
Vol 185 ◽  
pp. 304-307 ◽  
Author(s):  
Jiayang Wang ◽  
Chengxiong Gu ◽  
Mingxin Gao ◽  
Wenyuan Yu ◽  
Yang Yu
2016 ◽  
Vol 65 (06) ◽  
pp. 432-441 ◽  
Author(s):  
Deng Yun-dan ◽  
Du Wen-jing ◽  
Xiao Xi-jun

Background The selection of mitral valve surgery, including mitral valve repair and mitral valve replacement, is still an important dilemma for patients with chronic ischemic mitral regurgitation. We carry out a meta-analysis to evaluate the effectiveness and safety of mitral valve repair versus replacement for ischemic mitral regurgitation. Methods We searched PubMed, Embase, the Cochrane Library, and Web of Science to identify studies from their inception to July 2015. A meta-analysis was performed using RevMan 5.3 software (Cochrane Collaboration, Oxford, United Kingdom). A random-effect model was used and sensitivity analysis was performed on studies reporting on operation after 2000, high-quality studies, and those studies reporting on more than 150 patients. Result A total of 2,324 patients were identified from 10 retrospective studies. Mitral valve repair was associated with a trend toward lower operative mortality (odds ratio [OR] = 0.45; 95% confidence interval [CI]: 0.31–0.65; p < 0.0001) and higher recurrence of mitral regurgitation (OR = 5.89; 95% CI: 3.34–10.39; p < 0.00001). Five-year survival rate was similar between the two groups (OR = 1.20; 95% CI: 0.88–1.65; p = 0.25). No differences in reoperation, the incidence of acute renal failure and acute respiratory failure, the length of ICU stay, and the length of hospital stay were found. Conclusion Mitral valve repair was associated with lower operative mortality but a higher recurrence of mitral regurgitation compared with mitral valve replacement. Owing to the limited quantity and quality of the included studies, this conclusion still needs to be further confirmed by conducting more high-quality, multicenter randomized controlled trials with large sample size.


2018 ◽  
Vol 33 (12) ◽  
pp. 827-835 ◽  
Author(s):  
Hisato Takagi ◽  
Yosuke Hari ◽  
Norikazu Kawai ◽  
Toshiki Kuno ◽  
Tomo Ando ◽  
...  

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Akito Imai ◽  
Arash Khamooshian ◽  
Keitaro Okamoto ◽  
Yoshiaki Saito ◽  
Inez J. Wijdh-den Hamer ◽  
...  

Abstract Background Transcatheter mitral valve replacement (TMVR) is a challenging, but promising minimally invasive treatment option for patients with mitral valve disease. Depending on the anchoring mechanism, complications such as mitral leaflet or chordal disruption, aortic valve disruption or left ventricular outflow tract obstruction may occur. Supra-annular devices only anchor at the left atrial (LA) level with a low risk of these complications. For development of transcatheter valves based on LA anchoring, animal feasibility studies are required. In this study we sought to describe LA systolic and diastolic geometry in an ovine ischemic mitral regurgitation (IMR) model using magnetic resonance imaging (MRI) and echocardiography in order to facilitate future research focusing on TMVR device development for (I)MR with LA anchoring mechanisms. Methods A group of 10 adult male Dorsett sheep underwent a left lateral thoracotomy. Posterolateral myocardial infarction was created by ligation of the left circumflex coronary artery, the obtuse marginal and diagonal branches. MRI and echocardiography were performed at baseline and 8 weeks after myocardial infarction (MI). Results Six animals survived to 8 weeks follow-up. All animals had grade 2 + or higher IMR 8 weeks post-MI. All LA geometric parameters did not change significantly 8 weeks post-MI compared to baseline. Diastolic and systolic interpapillary muscle distance increased significantly 8 weeks post-MI. Conclusions Systolic and diastolic LA geometry do not change significantly in the presence of grade 2 + or higher IMR 8 weeks post-MI. These findings help facilitate future tailored TMVR device development with LA anchoring mechanisms.