scholarly journals Endovascular Fibrin Sheath-associated MRSA Bacteremia with Osler’s nodes

Author(s):  
Aline Le ◽  
Nasiffa Hossain
Keyword(s):  
2019 ◽  
Author(s):  
Raafat Shalabi ◽  
Mahmoud Maamoun
Keyword(s):  

Author(s):  
Rodríguez-Guerra, Miguel, MD ◽  
Pandey, Neelanjana MD ◽  
Shrestha, Elina, MD ◽  
Vittorio, Timothy J. MD

Background: The promotion of clinical abilities could represent a significant factor leading the clinicians to in making the correct diagnosis in a timely matter. Case: Our patient is a 42-year-old African male with a history of Hypertension, ESRD on hemodialysis via right-sided Permcath (PC), Mastoidectomy & Right ear surgery due to trauma in childhood, AV Fistula (Needed intervention 4 times) in left upper extremity, admitted due to witnessed seizures in the setting of hypertensive emergency. The patient denied family history and toxic habits. While the patient was at the emergency room, CT head revealed stable curvilinear hyper-attenuation thought to be a thrombosed developmental vein more likely than small subarachnoid hemorrhage. He was loaded with levetiracetam, received Ativan 1mg IV and HD done as per Nephrology. The patient was transferred to the floor he was not in acute distress and was asymptomatic, the cardiovascular (CV) examination showed regular pulse, normal S1, S2, S4+ appreciated with 2/4 diastolic murmur at second right intercostal space (ICS); 2/6 pansystolic murmur at third right intercostal space left parasternal border (LPSB) radiated to the right parasternal border (RPSB) and right mid-clavicular line (MCL); 3/6 systolic murmur at 5LICS MCL radiated to the posterior axillar line (PAL). Point of maximal impulse (PMI) displaced to mid axillar line (MAL). Parasternal heave present; the neurological exam was preserved. Endocarditis was suspected and echocardiogram was expedited, it showed severe aortic regurgitation, 1.60cm x 1.68cm mass in the tip of the catheter in the right atrium, possible vegetation in the tricuspid valve with mild regurgitation, moderate mitral valve regurgitation. Later, staphylococcus epidermidis was identified in blood cultures twice, as well as the culture from the PC. The transesophageal echocardiogram found 2.41 X 0.62 cm mass appears to be a fibrin sheath, possibly remnant of a prior catheter, small perforation in the non-coronary cusp likely in the setting of healed endocarditis. Infectious disease onboard for antibiotic management. Conclusion: The art of the clinician goes beyond the available technology; it could prevent the loss of critical time as well as unnecessary studies, guiding a better assessment and treatment of our patients and potentially improving their outcomes.


1997 ◽  
Vol 12 (5) ◽  
pp. 1048-1050 ◽  
Author(s):  
M. Winn ◽  
V. McDermott ◽  
S. Schwab ◽  
P. Conlon

2019 ◽  
Vol 100 (3) ◽  
pp. 157-162 ◽  
Author(s):  
A.B. Maldonado-Cárceles ◽  
J. García-Medina ◽  
J.J. García-Alfonso ◽  
J.J. Árense-Gonzalo ◽  
A.M. Torres-Cantero

2020 ◽  
pp. 112972982096932
Author(s):  
Patrycja S Matusik ◽  
Piotr Łoboda ◽  
Katarzyna Krzanowska ◽  
Tadeusz J Popiela ◽  
Grzegorz Heba ◽  
...  

Central venous catheters (CVC) are used in many clinical settings for a variety of indications. We performed a systematic literature review concerning case reports of retained calcified fibrin sheaths after dialysis CVC removal. The aim of our study was to systematize the knowledge regarding clinical management of this phenomenon, placing special emphasis on diagnostic radiological features in different imaging modalities, including chest radiography, echocardiography, computed tomography, and magnetic resonance imaging. We discuss the most common risk factors associated with this CVC complication. In our review, we found eight cases of hemodialysis patients. The most common risk factors associated with calcified fibrin sheath formation in the analyzed cases were pro-thrombotic and pro-calcification factors related to patient comorbidities, and prolonged catheter dwell time. Differentiating between a calcified fibrin sheath (present in about 6% of patients with long-term indwelling CVC as diagnosed by computed tomography) and a retained catheter tip can be challenging. The initial diagnosis based on imaging methods was incorrect in most of the analyzed cases. This suggests that some cases of retained fibrin sheaths may remain undetected or misinterpreted. This is important in patients with known pro-thrombotic and pro-calcification risk factors and prolonged catheter dwell time. Therefore, implementation of preventive strategies, familiarity with radiological findings of this phenomenon, comparison with previous imaging studies, and an overall comprehensive assessment with clinical data is imperative.


2015 ◽  
Vol 95 (5) ◽  
pp. 472-479 ◽  
Author(s):  
Maria Boddi ◽  
Gianluca Villa ◽  
Marco Chiostri ◽  
Francesco De Antoniis ◽  
Ilaria De Fanti ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document