scholarly journals TCT-36 Circumferential distribution of the neointima tissue at 6 months and 2 at years follow-up after a bioresorbable scaffold implantation. A serial optical coherence tomography study

2012 ◽  
Vol 60 (17) ◽  
pp. B11
Author(s):  
Christos Bourantas ◽  
Vasim Farooq ◽  
Hector M. Garcia-Garcia ◽  
Yoshinobu Onuma ◽  
Patrick Serruys ◽  
...  
Open Heart ◽  
2019 ◽  
Vol 6 (1) ◽  
pp. e000941 ◽  
Author(s):  
Jo Krogsgaard Simonsen ◽  
Emil Nielsen Holck ◽  
Didier Carrié ◽  
Norbert Frey ◽  
Matthias Lutz ◽  
...  

ObjectivesWe aimed to evaluate the mechanical properties and healing patterns 6 and 9 months after implantation of the sirolimus-eluting Fantom bioresorbable scaffold (BRS).BackgroundThe Fantom BRS (Reva Medical, San Diego, USA) has differentiating properties including radiopacity, strut thickness of 125 µm, high expansion capacity and has demonstrated favourable mid-term clinical and angiographic outcomes.Methods and resultsFANTOM II was a prospective, single arm study with implantation of the Fantom BRS in 240 patients with stable angina pectoris. Guidance by optical coherence tomography (OCT) was encouraged and was repeated at 6-month (cohort A) or 9-month follow-up (cohort B). Matched baseline and follow-up OCT recordings were available in 152 patients. In-scaffold mean lumen area in cohort A was 6.8±1.7 mm2 and 5.7±1.4 mm2 at baseline and follow-up (p<0.0001) and was 7.2±1.6 mm2 and 5.6±1.4 mm2 in cohort B (p<0.0001). Mean scaffold area remained stable from 7.1±1.5 mm2 at baseline to 7.2±1.4 mm2 at 6 months (p=0.12), and from 7.4±1.5 mm2 to 7.3±1.4 mm2 at 9 months. Strut malapposition was median 0.8 (IQR 0.0;3.5)% and 1.8 (IQR 0.3;6.0)% at baseline and was 0.0 (IQR 0.0;0.0)% in both groups at 6-month and 9-month follow-up. Strut tissue coverage was 98.1 (IQR 95.9;99.4)% at 6 months and 98.9 (IQR 98.3;100.0)% at 9 months.ConclusionsThe novel Fantom BRS had favourable healing patterns at 6-month and 9-month follow-up as malapposition was effectively resolved and strut coverage was almost complete. The scaffold remained stable through follow-up with no signs of systematic late recoil.


2021 ◽  
pp. 247412642198961
Author(s):  
Ioannis S. Dimopoulos ◽  
Michael Dollin

Purpose: Epiretinal membrane (ERM) is a common retinal finding for patients older than 50 years. Disorganization of the retinal inner layers (DRIL) has emerged as a novel predictor of poor visual acuity (VA) in eyes with inner retinal pathology. The aim of our study is to correlate preoperative DRIL with visual outcomes after ERM surgery. Methods: Medical records and optical coherence tomography (OCT) images of 81 pseudophakic patients who underwent treatment of idiopathic ERM were reviewed. Preoperative DRIL on OCT was correlated with VA at baseline and at 3 and 6 months after ERM surgery. DRIL was defined as the loss of distinction between the ganglion cell–inner plexiform layer complex, inner nuclear layer, and outer plexiform layer. DRIL severity was based on its extent within the central 2-mm region of a transfoveal B-scan (absent/mild: <one-third, severe: >one-third horizontal width). Results: Review of preoperative OCT showed severe DRIL in 41% and absent/mild DRIL in 59%. Severe DRIL was associated with worse baseline VA ( P < .001). Preoperative VA and DRIL status at baseline were both predictors of postoperative VA at follow-up time points ( P < .001). Severe DRIL was associated with significantly less improvement in VA at 6 months (–0.23 logMAR for absent/mild vs –0.14 for severe DRIL). Conclusions: Presence of severe preoperative DRIL correlates with worse baseline VA in patients with ERM and reduced VA improvement at 6 months. DRIL can be a strong predictor of long-term poor visual outcomes in ERM surgery.


2021 ◽  
Vol 10 (2) ◽  
pp. 231
Author(s):  
Giacinto Triolo ◽  
Piero Barboni ◽  
Giacomo Savini ◽  
Francesco De Gaetano ◽  
Gaspare Monaco ◽  
...  

The introduction of anterior-segment optical-coherence tomography (AS-OCT) has led to improved assessments of the anatomy of the iridocorneal-angle and diagnoses of several mechanisms of angle closure which often result in raised intraocular pressure (IOP). Continuous advancements in AS-OCT technology and software, along with an extensive research in the field, have resulted in a wide range of possible parameters that may be used to diagnose and follow up on patients with this spectrum of diseases. However, the clinical relevance of such variables needs to be explored thoroughly. The aim of the present review is to summarize the current evidence supporting the use of AS-OCT for the diagnosis and follow-up of several iridocorneal-angle and anterior-chamber alterations, focusing on the advantages and downsides of this technology.


2014 ◽  
Vol 64 (11) ◽  
pp. B188
Author(s):  
Antonios Karanasos ◽  
Cordula Felix ◽  
Floris Kauer ◽  
Nicolas M. Van Mieghem ◽  
Roberto Diletti ◽  
...  

2011 ◽  
Vol 57 (14) ◽  
pp. E1735
Author(s):  
Daisuke Nakamura ◽  
Masami Nishino ◽  
Yasuharu Lee ◽  
Takahiro Yoshimura ◽  
Masayuki Taniike ◽  
...  