bioresorbable scaffold
Recently Published Documents


TOTAL DOCUMENTS

387
(FIVE YEARS 94)

H-INDEX

23
(FIVE YEARS 5)

Author(s):  
Christian Oliver Fallesen ◽  
Lisbeth Antonsen ◽  
Akiko Maehara ◽  
Manijeh Noori ◽  
Mikkel Hougaard ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Piotr Rola ◽  
Adrian Włodarczak ◽  
Mateusz Barycki ◽  
Marek Szudrowicz ◽  
Magdalena Łanocha ◽  
...  

Background. Cardiovascular disease (CVD) with significant involvement of coronary artery disease (CAD) remains a major cause of death and disability among the diabetic population. Although percutaneous coronary intervention (PCI) continues to evolve, type 2 diabetes mellitus (T2DM) is a well-established marker of poor clinical prognosis after PCI, which is mainly attributed to the rapid progression of atherosclerosis requiring recurrent revascularizations. Hence, the use of bioresorbable materials could provide some solution to this problem. Material and Methods. The study was divided into two arms. For the first one, we qualified 169 patients with NSTE-ACS treated with PCI who received the drug-eluting stent (DES) coated with a biodegradable polymer Ultimaster (Terumo, Tokyo, Japan). The second arm was composed of 193 patients with ACS who underwent PCI with a magnesium bioresorbable scaffold Magmaris (Biotronik, Berlin, Germany). Both arms were divided into two subsequent groups: the T2DM (59 and 72) and the non-DM (110 and 121, respectively). The primary outcomes were cardiovascular death, myocardial infarction, and in-stent thrombosis. The main secondary outcomes included target lesion failure (TLF) and were recorded at a 1-year-follow-up. Results. There were no significant differences between the diabetic and nondiabetic populations in primary endpoints or main secondary endpoints (TLF, scaffold restenosis, death from any reason, and other cardiovascular events) either in the Ultimaster or Magmaris group. At a 1-year-follow-up, the primary endpoint in the DM t.2 population was recorded in 2.7% Ultimaster vs. 5.1% Magmaris, respectively. At the same time, the TLF occurred in the diabetic group in 4.1% Magmaris and 3.3% in the Ultimaster arm, respectively. Conclusion. Both, Ultimaster and Magmaris revealed relative safety and efficiency at a one-year follow-up in the diabetic population in ACS settings. The observed rates of TLF were low, which combined with a lack of in-stent thrombosis suggests that both investigated devices might be an interesting therapeutic option for diabetics with ACS. Nevertheless, further large randomized clinical trials are needed to confirm fully our results.


Open Heart ◽  
2021 ◽  
Vol 8 (2) ◽  
pp. e001776
Author(s):  
Mehdi Madanchi ◽  
Giacomo Maria Cioffi ◽  
Adrian Attinger-Toller ◽  
Mathias Wolfrum ◽  
Federico Moccetti ◽  
...  

BackgroundEarly studies evaluating the performance of bioresorbable scaffold (BRS) Absorb in in-stent restenosis (ISR) lesions indicated promising short-term to mid-term outcomes.AimsTo evaluate long-term outcomes (up to 5 years) of patients with ISR treated with the Absorb BRS.MethodsWe did an observational analysis of long-term outcomes of patients treated for ISR using the Absorb BRS (Abbott Vascular, Santa Clara, California, USA) between 2013 and 2016 at the Heart Centre Luzern. The main outcomes included a device-oriented composite endpoint (DOCE), defined as composite of cardiac death, target vessel (TV) myocardial infarction and TV revascularisation, target lesion revascularisation and scaffold thrombosis (ScT).ResultsOverall, 118 ISR lesions were treated using totally 131 BRS among 89 patients and 31 (35%) presented with an acute coronary syndrome. The median follow-up time was 66.3 (IQR 52.3–77) months. A DOCE had occurred in 17% at 1 year, 27% at 2 years and 40% at 5 years of all patients treated for ISR using Absorb. ScTs were observed in six (8.4%) of the cohort at 5 years.ConclusionsTreatment of ISR using the everolimus-eluting BRS Absorb resulted in high rates of DOCE at 5 years. Interestingly, while event rates were low in the first year, there was a massive increase of DOCE between 1 and 5 years after scaffold implantation. With respect to its complexity, involving also a more unpredictable vascular healing process, current and future BRS should be used very restrictively for the treatment of ISR.


Author(s):  
Ben Hoddy ◽  
Naveed Ahmed ◽  
Kadem Al-Lamee ◽  
Nial Bullett ◽  
Nick Curzen ◽  
...  

Author(s):  
Tieying Yin ◽  
Ruolin Du ◽  
Yang Wang ◽  
Junyang Huang ◽  
Shuang Ge ◽  
...  

2021 ◽  
Vol 10 (14) ◽  
pp. 3166
Author(s):  
Adrian Włodarczak ◽  
Magdalena Łanocha ◽  
Marek Szudrowicz ◽  
Mateusz Barycki ◽  
Alicja Gosiewska ◽  
...  

Background: Diabetes mellitus (DM) is one of the major risk factors contributing to Acute Coronary Syndromes (ACS) and is associated with an increased risk of adverse clinical outcomes following percutaneous coronary intervention (PCI), even when the second generation of drug-eluting stents (DES) is used. In order to overcome the disadvantages of permanent caging of a vessel with metallic DES, bioresorbable scaffold (BRS) technology has been recently developed. However, the prognosis of patients with DM and ACS treated with PCI via subsequent implantation of Magmaris (Biotronik, Berlin, Germany)—a novel magnesium-bioresorbable scaffold—is poorly investigated. Methods: A total of 193 consecutive subjects with non-ST elevation acute coronary syndrome (NSTE-ACS) who, from October 2016 to March 2020, received one or more Magmaris scaffolds were enrolled in this study. The diabetic group was compared with non-diabetic subjects. Results: There were no significant differences in the occurrence of primary endpoints (cardiovascular death, myocardial infarction, and in-stent thrombosis) and principal secondary endpoints (target-lesion failure, scaffold restenosis, death from any reason, and other cardiovascular events) between the two compared groups in a 1-year follow-up period. Conclusions: The early 1-year-outcome of magnesium bioresorbable scaffold (Magmaris) seems to be favorable and suggests that this novel BRS is safe and effective in subjects with NSTE-ACS and co-existing DM.


2021 ◽  
Vol 7 (23) ◽  
pp. eabf0614
Author(s):  
Danni Shen ◽  
Haiping Qi ◽  
Wenjiao Lin ◽  
Wanqian Zhang ◽  
Dong Bian ◽  
...  

Balancing the biodegradability and mechanical integrity of a bioresorbable scaffold (BRS) with time after implantation to match the remodeling of the scaffolded blood vessel is important, but a key challenge in doing so remains. This study presents a novel intercalated structure of a metallic BRS by introducing a nanoscale Zn sacrificial layer between the nitrided Fe platform and the sirolimus-carrying poly(d,l-lactide) drug coating. The PDLLA-Zn-FeN BRS shows a multistage biodegradation behavior, maintaining mechanical integrity at the initial stage and exhibiting accelerated biodegradation at the subsequent stage in both rabbit abdominal aortas and human coronary arteries, where complete biodegradation was observed about 2 years after implantation. The presence of the nanoscale Zn sacrificial layer with an adjustable thickness also contributes to the tunable biodegradation of BRS and allows the reduction of the metallic strut thickness to 53 μm, with radial strength as strong as that of the current permanent drug-eluting stents.


Sign in / Sign up

Export Citation Format

Share Document