scholarly journals TCT-534 To cover or not to cover deep femoral arteries in stenting for bifurcation lesions of superficial femoral artery

2013 ◽  
Vol 62 (18) ◽  
pp. B161-B162
Author(s):  
Sung-Jin Hong ◽  
Young-Guk Ko ◽  
Jung-Sun Kim ◽  
Myeong-Ki Hong ◽  
Yang soo Jang ◽  
...  
2008 ◽  
Vol 294 (4) ◽  
pp. H1833-H1839 ◽  
Author(s):  
S. C. Newcomer ◽  
C. L. Sauder ◽  
N. T. Kuipers ◽  
M. H. Laughlin ◽  
C. A. Ray

Shear rate is significantly lower in the superficial femoral compared with the brachial artery in the supine posture. The relative shear rates in these arteries of subjects in the upright posture (seated and/or standing) are unknown. The purpose of this investigation was to test the hypothesis that upright posture (seated and/or standing) would produce greater shear rates in the superficial femoral compared with the brachial artery. To test this hypothesis, Doppler ultrasound was used to measure mean blood velocity (MBV) and diameter in the brachial and superficial femoral arteries of 21 healthy subjects after being in the supine, seated, and standing postures for 10 min. MBV was significantly higher in the brachial compared with the superficial femoral artery during upright postures. Superficial femoral artery diameter was significantly larger than brachial artery diameter. However, posture had no significant effect on either brachial or superficial femoral artery diameter. The calculated shear rate was significantly greater in the brachial (73 ± 5, 91 ± 11, and 97 ± 13 s−1) compared with the superficial femoral (53 ± 4, 39 ± 77, and 44 ± 5 s−1) artery in the supine, seated, and standing postures, respectively. Contrary to our hypothesis, our current findings indicate that mean shear rate is lower in the superficial femoral compared with the brachial artery in the supine, seated, and standing postures. These findings of lower shear rates in the superficial femoral artery may be one mechanism for the higher propensity for atherosclerosis in the arteries of the leg than of the arm.


VASA ◽  
2006 ◽  
Vol 35 (1) ◽  
pp. 41-44 ◽  
Author(s):  
Klein-Weigel ◽  
Pillokat ◽  
Klemens ◽  
Köning ◽  
Wolbergs ◽  
...  

We report two cases of femoral vein thrombosis after arterial PTA and subsequent pressure stasis. We discuss the legal consequences of these complications for information policies. Because venous thrombembolism following an arterial PTA might cause serious sequel or life threatening complications, there is a clear obligation for explicit information of the patients about this rare complication.


VASA ◽  
2012 ◽  
Vol 41 (6) ◽  
pp. 458-462 ◽  
Author(s):  
Vogel ◽  
Strothmeyer ◽  
Cebola ◽  
A. Katus ◽  
Blessing

We demonstrate feasibility of implantation of a self-expanding interwoven nitinol stent in a claudicant, where recanalization attempt of a heavily calcified, occluded superficial femoral artery (TASC D lesion) was complicated by a previously implanted, fractured standard stent. Wire passage through the occlusion and beyond the fractured stent could only be achieved through the subintimal space. A dedicated reentry device was used to allow distal wire entry into the true lumen at the level of the popliteal artery. Despite crushing of the fractured stent with a series of increasingly sized standard balloons, a significant recoil remainded in the area of the crushed stent. To secure patency of the femoro-popliteal artery we therefore decided to implant the novel self-expanding interwoven nitinol stent (Supera Veritas (TM), IDEV), whose unique feature is an exceptional high radial strength. Patient presented asymptomatic without any impairment of his walking capacity at three month follow up and duplex ultrasound confirmed patency of the stent. Subintimal recanalizations can be complicated by previously implanted stents, in particular in the presence of stent fracture, where intraluminal wire passage often can not be achieved. Considering the high radial strength and fracture resistance, interwoven nitinol stents represent a good treatment option in those challenging cases and they can be used to crush standard nitinol and ballonexpandable stents.


VASA ◽  
2013 ◽  
Vol 42 (5) ◽  
pp. 382-386
Author(s):  
Karim Gariani ◽  
Marc Righini ◽  
Marco Roffi ◽  
Gino Gemayel ◽  
Damiano Mugnai ◽  
...  

2003 ◽  
Vol 10 (1) ◽  
pp. 121-125 ◽  
Author(s):  
David Rosenthal ◽  
Eric D. Wellons ◽  
John H. Matsuura ◽  
Mark Ghegan ◽  
Frederick W. Shuler ◽  
...  

2020 ◽  
Vol 61 (3) ◽  
Author(s):  
Enrico M. Marone ◽  
Luigi F. Rinaldi ◽  
Simona Chierico ◽  
Giulia Marazzi ◽  
Piernicola Palmieri ◽  
...  

2019 ◽  
Vol 60 (5) ◽  
Author(s):  
Konstantinos Stavroulakis ◽  
Angeliki Argyriou ◽  
Mike Watts ◽  
Joji J. Varghese ◽  
Bailey A. Estes ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hu Li ◽  
Seung-Woon Rha ◽  
Byoung Geol Choi ◽  
Se Yeon Choi ◽  
Sang Ki Moon ◽  
...  

Abstract Background Self-expanding nitinol stent (SENS) implantation is commonly oversized in the superficial femoral artery (SFA), and leads to chronic outward force (COF) and in-stent restenosis (ISR). This study aimed to investigate the impact of COF of oversizing SENS on ISR of SFA. Methods In patients with implanted SENS in SFA, intimal hyperplasia especially between proximal segment and distal segment was evaluated by quantitative angiography, and the impact of COF on mid-term angiographic outcomes was investigated. In addition, porcine model with implanted SENS was used to evaluate the impact of COF on angiographic and histopathologic outcomes at 1 month. Excised stented arteries were evaluated by histopathologic analysis. Results We analyzed 65 SENS in 61 patients with follow-up angiography at 6 months to 1 year. The baseline diameter was 6.8 ± 0.71 mm and length were 97.0 ± 33.8 mm for the SENS. The ratio of the diameter of the stent to the reference vessel was 1.3 ± 0.24 at the proximal portion and 1.53 ± 0.27 at the distal portion (P < 0.001). In the long SFA stent, stent-to-vessel ratio was significantly higher in the distal stent than in the proximal stent (1.3 ± 0.2 vs. 1.55 ± 0.25, P = 0.001). ISR incidence was higher at the distal stent (37.3% vs 52.6%, P = 0.029). All 11 pigs survived for 4 weeks after SENS implantation. The vessel diameter was 4.04 ± 0.40 mm (control group) vs 4.45 ± 0.63 mm (oversized group), and the implanted stent diameter was 5.27 ± 0.46 mm vs. 7.18 ± 0.4 mm (P = 0.001). The stent-to-vessel diameter ratio was 1.31 ± 0.12 versus 1.63 ± 0.20 (P < 0.001). After 4 weeks, restenosis % was 29.5 ± 12.9% versus 46.8 ± 21.5% (P = 0.016). The neointimal area was 5.37 ± 1.15 mm2 vs. 8.53 ± 5.18 mm2 (P = 0.05). The restenosis % was 39.34 ± 8.53% versus 63.97 ± 17.1% (P = 0.001). Conclusions COF is an important cause of restenosis in the distal portion of the SFA stent. Optimal sizing of the SFA stent is important to reduce the incidence of restenosis. Therefore, COF was an important factor of restenosis following distal SFA stenting.