Design and validation of a novel Cartesian biomechanical testing system with coordinated 6DOF real-time load control: application to the lumbar spine (L1–S, L4–L5)

2013 ◽  
Vol 46 (11) ◽  
pp. 1948-1954 ◽  
Author(s):  
Brian P. Kelly ◽  
Charles R. Bennett
2005 ◽  
Vol 5 (1) ◽  
pp. 85-94 ◽  
Author(s):  
Eric H. Ledet ◽  
Michael P. Tymeson ◽  
Darryl J. DiRisio ◽  
Benjamin Cohen ◽  
Richard L. Uhl

2013 ◽  
Vol 278-280 ◽  
pp. 831-834 ◽  
Author(s):  
Xiao Sun ◽  
Hao Zhou ◽  
Xiang Jiang Lu ◽  
Yong Yang

This paper designed a motor winding testing system, it can do the dielectric withstand voltage test of inter-turn under 30kV.The system can communicate effectively between PC and machine, by using the PC's powerful capacity of process data and PLC's better stability and the Labview's convenient UI. So the system has real-time data collection, preservation, analysis and other characteristics. This system is able to achieve factory testing and type testing of the motor windings facilitating. Various performance indicators were stable and reliable by field test during a long time.


2020 ◽  
Vol 33 (05) ◽  
pp. 301-307
Author(s):  
Masakazu Shimada ◽  
Tetsuya Takagi ◽  
Nobuo Kanno ◽  
Satoshi Yamakawa ◽  
Hiromichi Fujie ◽  
...  

Abstract Objective The aim of the study was to determine the changes in biomechanical characteristics following tibial plateau levelling osteotomy (TPLO) using simulated manual tests. Study Design Twenty-one stifles from healthy Beagle dogs that had undergone TPLO or had not (control) were first tested in the intact form, and then the cranial cruciate ligament (CrCL) was transected in each to provide four test situations: control-intact, control-CrCL-transected, TPLO-intact and TPLO-CrCL-transected. The stifles were then analysed using a robotic joint biomechanical testing system. The craniocaudal drawer, axial rotation and proximal compression tests were applied. Results The craniocaudal displacement during the drawer test was not significantly different between the control-intact and TPLO-intact. However, the displacement was significantly greater in the TPLO-CrCL-transected than in the control-intact. In the axial rotation test, the internal–external (IE) rotation was significantly greater in the TPLO-intact than in the control-intact. Similarly, the IE rotation was significantly greater in the TPLO-CrCL-transected than in the control-CrCL-transected. In the proximal compression test, craniocaudal displacement was not significantly different among the control-intact, TPLO-intact and TPLO-CrCL-transected. Conclusion These findings suggest that TPLO influences the tension of the collateral ligaments and might generate laxity of the tibiofemoral joint. Instability after the osteotomy might be associated with the progression of osteoarthritis.