HPLC-UV determination of erdafitinib in mouse plasma and its application to pharmacokinetic studies

2021 ◽  
Vol 1171 ◽  
pp. 122629
Author(s):  
Tarek Elawady ◽  
Alaa Khedr ◽  
Nahed El-Enany ◽  
Fathalla Belal
2019 ◽  
Vol 15 (5) ◽  
pp. 591-598 ◽  
Author(s):  
Haitham Alrabiah ◽  
Ahmed Bakheit ◽  
Sabray Attia ◽  
Gamal A.E. Mostafa

Background: Conivaptan inhibits two of vasopressin receptor (vasopressin receptor V1a and V2). Conivaptan is used for the treatment of hyponatremia, and in some instances, for the treatment of the heart failure. Methods: The present study aimed to develop a simple, sensitive, and accurate HPLC with ultraviolet detection for the assay of conivaptan (CON) in mouse plasma using bisoprolol as internal standard (IS). A precipitation procedure was used to extract CON and the IS from the mouse plasma. CON was chromatographically separated using a C18 analytical column at 25°C. The separation was carried out using a mixture of phosphate buffer (50 mM): acetonitrile (60: 40, v/v, pH 4.5) with a flow rate of 1.0 mL/min and detection was performed at 240 nm. Results: The assay was validated according to the US Food and Drug (FDA) guidelines. The method demonstrated linearity over a concentration range of 150 - 2000 ng/mL (correlation coefficient: r 2 = 0.9985). The mean recovery of CON from the mouse plasma was 101.13%. All validation parameters for CON were within the acceptable range. Conclusion: The investigated method has been shown to be suitable for estimating the CON in plasma samples, and this method is sensitive and highly selective, allowing the estimation of its concentrations up to the nano-scale. The suggested method was successfully used in a pharmacokinetic study of CON in mouse plasma.


2011 ◽  
Vol 73 (5-6) ◽  
pp. 599-603 ◽  
Author(s):  
Yingyong Zhao ◽  
Lili Wang ◽  
Hua Miao ◽  
Charlene C. Ho ◽  
Jing Li ◽  
...  

2016 ◽  
Vol 258 ◽  
pp. S306
Author(s):  
P. Singh ◽  
J. Perron ◽  
R. Michaud ◽  
M. Fonsi ◽  
Y. Lambert ◽  
...  
Keyword(s):  

Author(s):  
Zhibiao Yi ◽  
Lin Ma ◽  
Baoqiang Wang ◽  
Wenxuan Cai ◽  
Zheng Xiang

2018 ◽  
Vol 16 (1) ◽  
pp. 614-620
Author(s):  
Haitham Alrabiah ◽  
Mohammed Abunassif ◽  
Sabry Attia ◽  
Gamal Abdel-Hafiz Mostafa

AbstractA new, selective and sensitive HPLC method for the determination of lixivaptan, an oral selective vasopressin 2 (V2)-receptor antagonist, was investigated and validated. A Waters symmetry C18 column was used as a stationary phase in isocratic elution mode using a mobile phase composed of KH2PO4 (100 mM)-acetonitrile (40: 60, v/v) at a flow rate of 1.5 mL min-1. Diclofenac was used as the internal standard (IS). Lixivaptan and the IS were extracted from plasma by protein precipitation and were detected at 260 nm. Lixivaptan and diclofenac were eluted at 3.6 and 6.2 min, respectively. The developed method showed good linearity over the calibration range of 50 -1000 ng mL-1 with a lower limit of detection of 16.5 ng mL-1. The extraction percentage of lixivaptan in the mouse plasma was in the range of 88.88 - 114.43%, which indicates acceptable extraction. The aforementioned method was validated according to guidelines of the International Council on Harmonization (ICH). The intra- and inter-day coefficients of variation did not exceed 5.5%. This method was presented to be simple, sensitive, and accurate and was successfully adapted in a pharmacokinetic study of the profile of lixivaptan in mouse plasma. A mean maximum plasma concentration of lixivaptan of 113.82 ng mL-1 was achieved in 0.5 h after oral administration of a 10 mg kg-1 dose in mouse as determined using the developed method.


Sign in / Sign up

Export Citation Format

Share Document