Modelling of unstiffened flush end-plate bolted connections in fire

2006 ◽  
Vol 62 (1-2) ◽  
pp. 151-159 ◽  
Author(s):  
K.S. Al-Jabri ◽  
A. Seibi ◽  
A. Karrech
Keyword(s):  
2010 ◽  
Vol 163-167 ◽  
pp. 591-595
Author(s):  
Jing Feng Wang ◽  
Xin Yi Chen ◽  
Lin Hai Han

This paper studies structural behaviour of the blind bolted connections to concrete-filled steel tubular columns by a serial of experimental programs, which conducted involving eight sub-assemblages of cruciform beam-to-column joints subjected to monotonic loading and cyclic loading. The moment-rotation hysteretic relationships and failure models of the end plate connections have been measured and analyzed. A simplified analysis model for the blind bolted connections is proposed based on the component method. It is concluded that the blind bolted end plate connection has reasonable strength and stiffness, whilst the rotation capacity of the connection satisfies the ductility requirements for earthquake-resistance in most aseismic regions. This typed joint has excellent seismic performance, so it can be used in the moment-resisting composite frame.


2019 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Adam Roman Petrycki ◽  
Osama (Sam) Salem

Purpose In fire condition, the time to failure of a timber connection is mainly reliant on the wood charring rate, the strength of the residual wood section, and the limiting temperature of the steel connectors involved in the connection. The purpose of this study is to experimentally investigate the effects of loaded bolt end distance, number of bolt rows, and the existence of perpendicular-to-wood grain reinforcement on the structural fire behavior of semi-rigid glued-laminated timber (glulam) beam-to-column connections that used steel bolts and concealed steel plate connectors. Design/methodology/approach In total, 16 beam-to-column connections, which were fabricated in wood-steel-wood bolted connection configurations, in eight large-scale sub-frame test assemblies were exposed to elevated temperatures that followed CAN/ULC-S101 standard time-temperature curve, while being subjected to monotonic loading. The beam-to-column connections of four of the eight test assemblies were reinforced perpendicular to the wood grain using self-tapping screws (STS). Fire tests were terminated upon achieving the failure criterion, which predominantly was dependent on the connection’s maximum allowed rotation. Findings Experimental results revealed that increasing the number of bolt rows from two to three, each of two bolts, increased the connection’s time to failure by a greater time increment than that achieved by increasing the bolt end distance from four- to five-times the bolt diameter. Also, the use of STS reinforcement increased the connection’s time to failure by greater time increments than those achieved by increasing the number of bolt rows or the bolt end distance. Originality/value The invaluable experimental data obtained from this study can be effectively used to provide insight and better understanding on how mass-timber glulam bolted connections can behave in fire condition. This can also help in further improving the existing design guidelines for mass-timber structures. Currently, beam-to-column wood connections are designed mainly as axially loaded connections with no guidelines available for determining the fire resistance of timber connections exerting any degree of moment-resisting capability.


Author(s):  
Shuyuan Lin ◽  
Zhaohui Huang ◽  
Mizi Fan
Keyword(s):  

2012 ◽  
Vol 76 ◽  
pp. 133-143 ◽  
Author(s):  
Guo-Qiang Li ◽  
Ling-Zhu Chen ◽  
Jiao-Ting Li ◽  
Guo-Biao Lou
Keyword(s):  

2009 ◽  
Vol 9 (1) ◽  
pp. 1-15 ◽  
Author(s):  
Ying Hu ◽  
Buick Davison ◽  
Ian Burgess ◽  
Roger Plank
Keyword(s):  

1996 ◽  
Vol 122 (8) ◽  
pp. 926-935 ◽  
Author(s):  
Mohammed R. Bahaari ◽  
Archibald N. Sherbourne

Sign in / Sign up

Export Citation Format

Share Document