Journal of Structural Fire Engineering
Latest Publications


TOTAL DOCUMENTS

318
(FIVE YEARS 106)

H-INDEX

11
(FIVE YEARS 3)

Published By Emerald (Mcb Up )

2040-2317

2022 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Irindu Upasiri ◽  
Chaminda Konthesingha ◽  
Anura Nanayakkara ◽  
Keerthan Poologanathan ◽  
Gatheeshgar Perampalam ◽  
...  

PurposeLight-Gauge Steel Frame (LSF) structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel lipped channel sections negative fire performance, cavity insulation materials are utilized in the LSF configuration to enhance its fire performance. The applicability of lightweight concrete filling as cavity insulation in LSF and its effect on the fire performance of LSF are investigated under realistic design fire exposure, and results are compared with standard fire exposure.Design/methodology/approachA Finite Element model (FEM) was developed to simulate the fire performance of Light Gauge Steel Frame (LSF) walls exposed to realistic design fires. The model was developed utilising Abaqus subroutine to incorporate temperature-dependent properties of the material based on the heating and cooling phases of the realistic design fire temperature. The developed model was validated with the available experimental results and incorporated into a parametric study to evaluate the fire performance of conventional LSF walls compared to LSF walls with lightweight concrete filling under standard and realistic fire exposures.FindingsNovel FEM was developed incorporating temperature and phase (heating and cooling) dependent material properties in simulating the fire performance of structures exposed to realistic design fires. The validated FEM was utilised in the parametric study, and results exhibited that the LSF walls with lightweight concrete have shown better fire performance under insulation and load-bearing criteria in Eurocode parametric fire exposure. Foamed Concrete (FC) of 1,000 kg/m3 density showed best fire performance among lightweight concrete filling, followed by FC of 650 kg/m3 and Autoclaved Aerated Concrete (AAC) 600 kg/m3.Research limitations/implicationsThe developed FEM is capable of investigating the insulation and load-bearing fire ratings of LSF walls. However, with the availability of the elevated temperature mechanical properties of the LSF wall, materials developed model could be further extended to simulate the complete fire behaviour.Practical implicationsLSF structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel-lipped channel sections negative fire performance, cavity insulation materials are utilised in the LSF configuration to enhance its fire performance. The lightweight concrete filling in LSF is a novel idea that could be practically implemented in the construction, which would enhance both fire performance and the mechanical performance of LSF walls.Originality/valueLimited studies have investigated the fire performance of structural elements exposed to realistic design fires. Numerical models developed in those studies have considered a similar approach as models developed to simulate standard fire exposure. However, due to the heating phase and the cooling phase of the realistic design fires, the numerical model should incorporate both temperature and phase (heating and cooling phase) dependent properties, which was incorporated in this study and validated with the experimental results. Further lightweight concrete filling in LSF is a novel technique in which fire performance was investigated in this study.


2022 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Abdelkadir Fellouh ◽  
Abdelkader Bougara ◽  
Paulo Piloto ◽  
Nourredine Benlakehal

PurposeInvestigate the fire performance of eccentrically loaded concrete partially encased column (PEC), using the advanced calculation method (ANSYS 18.2, 2017) and the simple calculation method in Annex G of Eurocode 4 (EN 1994-1-2, 2005). This work examines the influence of a range of parameters on fire behaviour of the composite column including: eccentricity loading, slenderness, reinforcement, fire rating and fire scenario. In this study, ISO-834 (ISO834-1, 1999) was used as fire source.Design/methodology/approachCurrently, different methods of analysis used to assess the thermal behaviour of composite column exposed to fire. Analytical method named simplified calculation methods defined in European standard and numerical simulations named advanced calculation models are treated in this paper.FindingsThe load-bearing capacity of the composite column becomes very weak in the presence of the fire accident and eccentric loading, this recommends to avoid as much as possible eccentric loading during the design of construction building. The reinforcement has a slight influence on the temperature evolution; moreover, the reinforcement has a great contribution on the load capacity, especially in combined compression and bending. When only the two concrete sides are exposed to fire, the partially encased composite column presents a high load-bearing capacity value.Originality/valueThe use of a three-dimensional numerical model (ANSYS) allowed to describe easily the thermal behaviour of PEC columns under eccentric loading with the regard to the analytical method, which is based on three complex steps. In this study, the presence of the load eccentricity has found to have more effect on the load-bearing capacity than the slenderness of the composite column. Introducing a load eccentricity on the top of the column may have the same a reducing effect on the load-bearing capacity as the fire.


2022 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Bishwajeet Choubey ◽  
Virendra Kumar ◽  
Sekhar Chandra Dutta ◽  
Saurav Kumar Saikia

PurposeThe purpose of the paper is to mathematically model and predict the characteristics of thermo-mechanically treated (TMT) rebar when subjected to elevated temperatures.Design/methodology/approachData were collected from a few selected studies for developing the constitutive relations. Using the exposed temperature and the duration of heating as independent variables, the empirical relations were developed for determining the changes in mechanical properties of TMT rebars at elevated temperatures.FindingsRecrystallization of TMT rebar crystals took place around 500 °C, which led to a decrease in the dislocation density along with the increase of large-sized grains, resulting in the degradation of strength. Up to a temperature range of 500 °C, the normalized fracture strength was higher, while the normalized fracture strain is not so high. This indicated a failure of brittle nature.Originality/valueThis is an original work done by others as a study to theoretically predict the mechanical behavior of TMT rebars when exposed to elevated temperature.HighlightsThe TMT bars showed brittleness characteristics up to 500 °C and showed ductility characteristics after that on account of its recrystallization and extensive tempering of the outer martensitic rim around that temperature.The comparison between the super ductile (SD) TMT and the regular TMT exhibit shows that the SD-TMT bars were about 1.5 times more ductile than the normal ones.


2022 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Oluwamuyiwa Okunrounmu ◽  
Osama (Sam) Salem ◽  
George Hadjisophocleous

PurposeThe fire resistance of timber structures is heavily dependent on the fire behaviour of the connections between its structural elements. The experimental study presented in this paper aimed to investigate the fire performance of glued-laminated timber beam connections reinforced perpendicular-to-wood grain with self-tapping screws (STS).Design/methodology/approachTwo full-size fire experiments were conducted on glulam beam-end connections loaded in flexure bending. Two connection configurations, each utilizing four steel bolts arranged in two different patterns, were reinforced perpendicular to wood grain using STS. The bolt heads and nuts and the steel plate top and bottom edges were fire protected using wood plugs and strips, respectively. Each connection configuration was loaded to 100% of the ultimate design load of the weakest unreinforced configuration. The test assemblies were exposed to elevated temperatures that followed the CAN/ULC-S101 standard fire time–temperature curve.FindingsThe experimental results show that the influence of the STS was significant as it prevented the occurrence of wood splitting and row shear-out and as a result, increased the fire resistance time of the connections. The time to failure of both connection configurations exceeded the minimum fire resistance rating specified as 45 min for combustible construction in applicable building codes.Originality/valueThe experimental data show the effectiveness of a simple fire protection system (i.e. wood plugs and strips) along with the utilization of STS on the rotational behaviour, charring rate, fire resistance time and failure mode of the proposed hybrid mass timber beam-end connection configurations.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Mohammed Ahmed Abed ◽  
Eva Lubloy

PurposeFire can severely affect concrete structures and with knowledge of the properties of materials, the damage can be assessed. Aggregate, cement matrix and their interaction are the most important components that affect concrete behaviour at high temperatures. The effect of incorporating recycled concrete aggregate or cementitious materials, namely, cement type and pulverized fly ash, are reviewed to provide a better understanding of their involvement in fire resistance.Design/methodology/approachMore investigation research is needed to understand the fire resistance of such sustainable concrete that was already constructed. The present study illustrates the effect of using recycled concrete aggregate and cementitious materials on the fire resistance of concrete. To do so, a literature review was conducted and relevant data were collected and presented in a simple form. The author's selected research findings, which are related to the presents study, are also presented and discussed.FindingsRecycled concrete aggregate enhances the concrete behaviour at high temperatures when it substitutes the natural aggregate by reasonable substitution (more than 25–30%). It also almost eliminates the possibility of spalling. Moreover, utilizing both supplementary cementitious materials with recycled concrete aggregate can improve the fire resistance of concrete. The incorporation of pulverized fly ash and slag in Portland cement or blended cement can generally keep the mechanical properties of concrete at a higher level after heating to a high temperature.Originality/valueRecycled concrete aggregate enhances the concrete behaviour at high temperatures when it substitutes the natural aggregate by reasonable substitution (more than 25–30%). It also almost eliminates the possibility of spalling. Moreover, utilizing both supplementary cementitious materials with recycled concrete aggregate can improve the fire resistance of concrete. The incorporation of pulverized fly ash and slag in Portland cement or blended cement can generally keep the mechanical properties of concrete at a higher level after heating to a high temperature.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Yousef Al Rjoub ◽  
Ala Obaidat ◽  
Ahmed Ashteyat ◽  
Khalid Alshboul

PurposeThis study aims to conduct an experimental study and finite element model (FEM) to investigate the flexural behavior of heat-damaged beams strengthened/repaired by hybrid fiber-reinforced polymers (HFRP).Design/methodology/approachTwo groups of beams of (150 × 250 × 1,200) mm were cast, strengthened and repaired using different configurations of HFRP and tested under four-point loadings. The first group was kept at room temperature, while the second group was exposed to a temperature of 400°C.FindingsIt was found that using multiple layers of carbon fiber-reinforced polymer (CFRP) and glass fiber-reinforced polymer (GFRP) enhanced the strength more than a single layer. Also, the order of two layers of FRP showed no effect on flexural behavior of beams. Using a three-layer scheme (attaching the GFRP first and followed by two layers of CFRP) exhibited increase in ultimate load more than the scheme attached by CFRP first. Furthermore, the scheme HGC (heated beam repaired with glass and carbon, in sequence) allowed to achieve residual flexural capacity of specimen exposed to 400°C. Typical flexural failure was observed in control and heat-damaged beams, whereas the strengthened/repaired beams failed by cover separation and FRP debonding, however, specimen repaired with two layers of GFRP failed by FRP rupture. The FEM results showed good agreement with experimental results.Originality/valueFew researchers have studied the effects of HFRP on strengthening and repair of heated, damaged reinforced concrete (RC) beams. This paper investigates, both experimentally and analytically, the performance of externally strengthened and repaired RC beams, in flexure, with different FRP configurations of CFRP and GFRP.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Fuminobu Ozaki ◽  
Ying Liu ◽  
Kai Ye

PurposeThe purpose of this study is to clarify both tensile and shear strength for self-drilling screws, which are manufactured from high-strength, martensitic-stainless and austenitic stainless-steel bars, and the load-bearing capacity of single overlapped screwed connections using steel sheets and self-drilling screws at elevated temperatures.Design/methodology/approachTensile/shear loading tests for the self-drilling screw were conducted to obtain basic information on the tensile and shear strengths at elevated temperatures and examine the relationships between both. Shear loading tests for the screwed connections at elevated temperatures were conducted to examine the shear strength and transition of failure modes depending on the test temperature.FindingsThe tensile and shear strengths as well as the reduction factors at the elevated temperature for each steel grade of the self-drilling screw were quantified. Furthermore, either screw shear or sheet bearing failure mode depending on the test temperature was observed for the screwed connection.Originality/valueThe transition of the failure modes for the screwed connection could be explained using the calculation formulae for the shear strengths at elevated temperatures, which were proposed in this study.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Fuminobu Ozaki ◽  
Takumi Umemura

PurposeIn this study, the bending strength, flexural buckling strength and collapse temperature of small steel specimens with rectangular cross-sections were examined by steady and transient state tests with various heating and deformation rates.Design/methodology/approachThe engineering stress and strain relationships for Japan industrial standard (JIS) SN400 B mild steels at elevated temperatures were obtained by coupon tests under three strain rates. A bending test using a simple supported small beam specimen was conducted to examine the effects of the deformation rates on the centre deflection under steady-state conditions and the heating rates under transient state conditions. Flexural buckling tests using the same cross-section specimen as that used in the bending test were conducted under steady-state and transient-state conditions.FindingsIt was clarified that the bending strength and collapse temperature are evaluated by the full plastic moment using the effective strength when the strain is equal to 0.01 or 0.02 under fast strain rates (0.03 and 0.07 min–1). In contrast, the flexural buckling strength and collapse temperature are approximately evaluated by the buckling strength using the 0.002 offset yield strength under a slow strain rate (0.003 min–1).Originality/valueRegarding both bending and flexural buckling strengths and collapse temperatures of steel members subjected to fire, the relationships among effects of steel strain rate for coupon test results, heating and deformation rates for the heated steel members were minutely investigated by the steady and transient-state tests at elevated temperatures.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Riza Suwondo ◽  
Lee Cunningham ◽  
Martin Gillie ◽  
Made Suangga ◽  
Irpan Hidayat

PurposeThe robustness of building structures in a fire has recently drawn wide attention. This study presents the progressive collapse analysis of steel frame building structures under localised fire. The main objective of this study is to propose methods to enhance the structural collapse resistance of such structures in fire.Design/methodology/approachA modelling method was developed and validated against both experimental and analytical studies. Then, a series of robustness analyses were performed to investigate the interaction among the members and the pattern of load distribution within the structures. These analyses show that lateral resistance and load redistribution have a vital role in the robustness of the building. Thus, two approaches have been adopted to enhance the robustness of the focused steel frame during a fire.FindingsIt is found that increased size of floor beams and vertical bracing systems are effective measures in preventing whole structure collapse. The larger beam section is able to prevent catenary action so that the load in the failed columns can safely transfer to the adjacent columns without buckling. On the other hand, the bracing system improves the lateral resistance that can accommodate the lateral force when catenary action occurs in the beam.Originality/valuePrevious studies have focused on the collapse mechanism of steel frame structures. However, the parameters affecting the structural robustness in a fire have not yet been explored. To address this gap, this study adopted numerical modelling to undertake parametric studies to identify effective methods to improve the robustness of such structures under fire conditions.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Sachin Vijaya Kumar ◽  
N. Suresh

PurposeThe Reinforced Concrete(RC) elements are known to perform well during exposure to elevated temperatures. Hence, RC elements are widely used to resist the extreme heat developing from accidental fires and other industrial processes. In both of the scenarios, the RC element is exposed to elevated temperatures. However, the primary differences between the fire and processed temperatures are the rate of temperature increase, mode of exposure and exposure durations. In order to determine the effect of two heating modalities, RC beams were exposed to processed temperatures with slow heating rates and fire with fast heating rates.Design/methodology/approachIn the present study, RC beam specimens were exposed to 200 °C, to 800 °C temperature at 200 °C intervals for 2 h' duration by adopting two heating modes; Fire and processed temperatures. An electrical furnace with low-temperature increment and a fire furnace with standard time-temperature increment is adapted to expose the RC elements to elevated temperatures.FindingsIt is observed from test results that, the reduction in load-carrying capacity, first crack load, and thermal crack widths of RC beams exposed to 200 °C, and 600 °C temperature at fire is significantly high from the RC beams exposed to the processed temperature having the same maximum temperature. As the exposure temperature increases to 800 °C, the performance of RC beams at all heating modes becomes approximately equal.Originality/valueIn this work, residual performance, and failure modes of RC beams exposed to elevated temperatures were achieved through two different heating modes are presented.


Sign in / Sign up

Export Citation Format

Share Document