Headed stud shear connector for thin ultrahigh-performance concrete bridge deck

2015 ◽  
Vol 108 ◽  
pp. 23-30 ◽  
Author(s):  
Jee-Sang Kim ◽  
Jongwon Kwark ◽  
Changbin Joh ◽  
Sung-Won Yoo ◽  
Kyoung-Chan Lee
2020 ◽  
Vol 856 ◽  
pp. 99-105
Author(s):  
Krissachai Sriboonma ◽  
Sacharuck Pornpeerakeat

The research focuses on investigating different types of steel confinements around a clustered large-size stud shear connector using in full-depth precast concrete bridge deck panel. The tests were based on Push-off test of two main groups of specimens: (1) the specimens with 4-stud shear connector where three different types of confinement were adopted including of O-ring confinement, Wire-mesh confinement, and L-angle confinement), and (2) the specimens with 8-stud shear connector where two different types of confinement were investigated including of Plate-ring confinement and L-angle confinement. The test results concluded that L-angle confinement type of the group of specimens with 4-Stud is the most sufficient type comparing between the different types of confinement in the same group. The maximum resistance was found at 41-ton, while as the displacement was found to be the most expansible and gradually reduced until the failure point. This means that the sign of failure can be noticeable prior to a collapse of the structure. For the group of specimens with 8-Stud, the resistance of this group was higher than the group of specimens with 4-Stud about 50 - 100% increase depending on each type of confinement. The maximum resistance was found for Plate-ring confinement type at 70-ton, which was agreed with the increment of the displacement about 20 - 50%. In comparison between specimens with 8-Stud, the Plate-ring confinement showed greater resistance and more relative displacement about 15% than the L-angle confinement.


PCI Journal ◽  
2011 ◽  
Vol 56 (3) ◽  
pp. 43-59 ◽  
Author(s):  
Sean R. Sullivan ◽  
Carin L. Roberts-Wollmann ◽  
Matthew K. Swenty

PCI Journal ◽  
1995 ◽  
Vol 40 (1) ◽  
pp. 59-80 ◽  
Author(s):  
Mohsen A. lssa ◽  
Ahmad-Talalldriss ◽  
lraj I. Kaspar ◽  
Salah Y. Khayyat

Author(s):  
Petr Konečný ◽  
Petr Lehner ◽  
David Pustka

The paper is focused on the model of the effect of delayed chloride exposure on the chloride induced corrosion initiation on ideal reinforced concrete bridge. The Finite Element-based numerical model is applied. The effect of concrete quality is expressed in the form of time dependent diffusion coefficient in order to evaluate the effect of concrete type as well as the effect of aging. The influence of extended chloride exposure on the corrosion initiation is introduced.


2021 ◽  
Vol 293 ◽  
pp. 123520
Author(s):  
Ningyi Su ◽  
Liangwei Lou ◽  
Armen Amirkhanian ◽  
Serji N. Amirkhanian ◽  
Feipeng Xiao

2014 ◽  
Vol 1004-1005 ◽  
pp. 1474-1477
Author(s):  
Ze Ying Yang ◽  
Jia You Liu ◽  
Yi Dong Zhang ◽  
Jian Bo Qu

By numerical simulation and contrasting with experimental conclusions, mechanical models in every loading stage of CFRP reinforced concrete bridge deck were established. The results showed that, numerical simulation results of non-prestressed bridge decks fitted corresponding test results well. The stiffness of prestressed structures had been greatly improved than non-prestressed structures, so the high strength performance of CFRP had been used more effectively.


Sign in / Sign up

Export Citation Format

Share Document