The influence of non-uniform blockages on transient wave behavior and blockage detection in pressurized water pipelines

2017 ◽  
Vol 17 ◽  
pp. 1-7 ◽  
Author(s):  
H.F. Duan ◽  
P.J. Lee ◽  
T.C. Che ◽  
M.S. Ghidaoui ◽  
B.W. Karney ◽  
...  
2014 ◽  
Vol 70 ◽  
pp. 573-582 ◽  
Author(s):  
H.-F. Duan ◽  
P. Lee ◽  
M. Ghidaoui

Author(s):  
Fabien Crouzet ◽  
Vincent Faucher ◽  
Pascal Galon ◽  
Philippe Piteau ◽  
Patrick Izquierdo

The propagation of a transient wave through an orifice is investigated for applications to Loss Of Coolant Accident in nuclear plants. An analytical model is proposed for the response of an orifice plate and implemented in the EUROPLEXUS fast transient dynamics software. It includes an acoustic inertial effect in addition to a quasi-steady dissipation term. The model is experimentally validated on a test rig consisting in a single pipe filled with pressurized water. The test rig is designed to generate a rapid depressurization of the pipe, by means of a bursting disk. The proposed model gives results which compare favourably with experimental data.


2018 ◽  
Vol 144 (8) ◽  
pp. 04018054 ◽  
Author(s):  
T. C. Che ◽  
H. F. Duan ◽  
P. J. Lee ◽  
B. Pan ◽  
M. S. Ghidaoui

2021 ◽  
Vol 147 (2) ◽  
pp. 04020095
Author(s):  
X. F. Yan ◽  
H. F. Duan ◽  
X. K. Wang ◽  
M. L. Wang ◽  
P. J. Lee

1985 ◽  
Vol 20 (1) ◽  
pp. 237-245 ◽  
Author(s):  
S. H. Joseph ◽  
P. S. Leevers

2019 ◽  
Vol 19 (8) ◽  
pp. 2347-2358
Author(s):  
Chengchao Guo ◽  
Kunming Shi ◽  
Xuanxuan Chu

Abstract Leakage of water pipelines will significantly endanger the safety operation and service performance of the pipelines. Based on the vibration of pressurized water pipelines deriving from leakage, the BA-FH3200 fiber optic hydrophone (FOH) leakage detection long-term detection system was adopted in prototype tests. The vibration-based real-time leakage monitoring method of the pressurized water pipeline was studied. During the test, the leakage was simulated by opening a spherical valve in the middle of the pipe, and an FOH was placed right above the pipe wall to detect the vibration signal along the pipe. The FOH analysis software was used to monitor the pipeline operation status in real time and acquire data. Then, the data were processed by a self-developed post-processing program, and the parameters were optimized through back-calculation. The test results reveal that the leakage positioning error lay between ±0.07 m, and real-time monitoring (i.e., early warning alarm and leakage positioning) of the FOH for the pressurized water pipeline was feasible.


2022 ◽  
Vol 167 ◽  
pp. 108512
Author(s):  
Ying Zhang ◽  
Huan-Feng Duan ◽  
Alireza Keramat ◽  
Tong-Chuan Che

Sign in / Sign up

Export Citation Format

Share Document