Long-term wear failure analysis of uhmwpe acetabular cup in total hip replacement

Author(s):  
N. Shahemi ◽  
S. Liza ◽  
A.A. Abbas ◽  
AM Merican
VCOT Open ◽  
2020 ◽  
Vol 03 (02) ◽  
pp. e129-e133
Author(s):  
Stephanie M.M. Colthurst ◽  
James O. Simcock ◽  
Ricky G. Cashmore

Abstract Objective The aim of this study was to report the successful revision of a loose perforated press-fit cup by exchange with a porous-coated press-fit cup while maintaining the original locking stem and head–neck unit. Methods Cup revision was performed in a dog with a loose acetabular cup that had undergone total hip replacement with a perforated press-fit cup and locking stem 29 months previously. The original locking stem was well integrated. A single session cup exchange was performed by implantation of a 28-mm porous-coated press-fit cup with 16 mm internal diameter to allow the original locking stem and head–neck unit to be preserved. Results Revision total hip arthroplasty by cup exchange resulted in excellent functional outcome with long-term follow-up 18 months postoperatively. There were no intraoperative or postoperative complications. Conclusion A loose perforated press-fit cup was successfully revised with a porous press-fit cup while allowing preservation of the initial locking stem and head–neck unit.


2007 ◽  
Vol 361-363 ◽  
pp. 791-794 ◽  
Author(s):  
Laurent Gremillard ◽  
Jérôme Chevalier

Ceramics have been increasingly used in orthopaedics during the last 30 years. Their biological inertness, high hardness and good mechanical strength make them excellent candidates for components such as femoral heads and acetabular cup in Total Hip Replacement prostheses. Currently used bio-inert ceramics – alumina and zirconia – give good clinical results, especially compared to metal – polymer couplings. However, they are subjected to severe biological, tribological and mechanical solicitations during more than fifteen years for the most successful prostheses. They answer these solicitations by presenting specific degradation mechanisms. We will thus examine the phenomena that can account for the long-term behaviour of zirconia components (heads and cups) in THR prostheses.


2009 ◽  
Vol 19 (2) ◽  
pp. 120-127 ◽  
Author(s):  
Samuel S. Rajaratnam ◽  
Shaun A. Sexton ◽  
Tim S. Waters ◽  
William L. Walter ◽  
Bernard A. Zicat ◽  
...  

Fifteen patients (16 hips) with an ankylosed hip joint for a mean of 36 years (3.5 to 65), had their hips converted to a cementless Total Hip Replacement (THR). They were followed-up for a median of 10.75 years (5.0 to 19) with none lost to follow-up. All patients showed improved mobility and function post-operatively. The Harris Hip Score improved from 70 (SEM 3.4) to 83 post-operatively (SEM 4.4), which was statistically significant (p < 0.05). There was one acetabular cup revision at 5 years post implantation for aseptic loosening. All other femoral and acetabular components remained clinically and radiographically well fixed. We conclude that a previously ankylosed hip can be effectively converted to a cementless total hip replacement with good long term results.


Author(s):  
A W Miles ◽  
P B McNamee

Aseptic loosening of the acetabular component is the principal long-term complication in total hip replacement. Radiographic evidence suggests a higher incidence of loosening with medialization of the axis of rotation of the acetabular cup. A simplified two-dimensional photoelastic investigation of the load transfer in the pelvis demonstrates that the stress distribution is substantially changed when this axis of rotation is medialized. Strain gauge measurements on three dry hemi-pelvic bones confirm this effect. It is postulated that the redistribution of load resulting from medialization may result in inadequate skeletal support for the acetabular component predisposing to loosening.


1986 ◽  
Vol 1 (4) ◽  
pp. 229-236 ◽  
Author(s):  
Paul F. Lachiewicz ◽  
Byron D. Rosenstein

Author(s):  
Renée Huggard ◽  
Grace Wicks ◽  
Gordon Corfield

Abstract Objective The aim of this study was to assess the short-term clinical outcome in dogs following a hip hemi-arthroplasty for the treatment of primary pathological disorders of the hip and as a salvage procedure following failure of the cup component of a total hip replacement. Materials and Methods Medical records of dogs that had a unilateral hip hemi-arthroplasty performed between 2015 and 2020 were reviewed. Data collected included follow-up orthopaedic examinations performed at 0, 2, 8 and 52 weeks postoperatively, pelvic radiography at 0, 8 and 52 weeks postoperatively and an owner questionnaire (Helsinki chronic pain index [HCPI]). Results Eleven unilateral hip hemi-arthroplasty procedures were identified. The median age at time of surgery was 3.6 years (8 months–10 years) and the median follow-up time was 13 months (range: 2 months–3 years). The HCPI for all dogs at follow-up was median 8 ± 7.30 (range: 5–25). Total HCPI was < 12 for 7/10 dogs and ≥ 12 for 3 dogs. Pelvic radiographs at 1 year confirmed osteointergration of the femoral stem implant and no evidence of implant subsidence or progression of osteoarthritis. However, there was some evidence of mild lucency of the acetabular bed around the prosthetic femoral head and mild peri-acetabular sclerosis in four cases. Conclusion Hip hemi-arthroplasty provides a clinically acceptable treatment for disabling disease of the coxofemoral joint with 10/11 patients achieving acceptable short-term clinical function. Long-term assessment of the hip hemi-arthroplasty and comparison with total hip replacement is indicated.


1985 ◽  
Vol 16 (4) ◽  
pp. 757-769 ◽  
Author(s):  
Charles N. Cornell ◽  
Eduardo A. Salvati ◽  
Paul M. Pellicci

Sign in / Sign up

Export Citation Format

Share Document