Abstract No. 47: Percutaneous transhepatic tunneled catheter for long term venous access in children with short gut syndrome

2011 ◽  
Vol 22 (3) ◽  
pp. S23 ◽  
Author(s):  
S. Subramanian ◽  
G. Narayanan
2017 ◽  
Vol 22 (4) ◽  
pp. 205-209 ◽  
Author(s):  
Dewansh Goel ◽  
Bhupender Yadav ◽  
Paul Lewis ◽  
Karun Sharma ◽  
Ranjith Vellody

Abstract Establishing venous access can be an important and often complex aspect of care for pediatric patients. When stable central venous access is required for long-term intravenous infusions, several options are available including peripherally inserted central catheters (PICC), tunneled catheters and ports. Both PICC placement and tunneled catheter placement include an exposed external segment of catheter, either in an extremity or on the chest. We present a pediatric patient with complex behavioral history who required long-term intravenous therapy. After careful review, the best option for the patient was determined to be a tunneled catheter that exited the skin in the right upper back, making it difficult to grab and pull out. The catheter was successfully placed and the patient appropriately completed his intravenous antibiotic course. Upon completion, the catheter was removed without complications. This tunneling technique to the scapular region may be useful for patients with psychiatric or neurodegenerative disorders where purposeful dislodgement may be a problem.


1998 ◽  
Vol 2 (1) ◽  
pp. 38-40
Author(s):  
Franco Tesio ◽  
Hamurabi De Baz ◽  
Giacomo Panarello

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yuuki Iida ◽  
Kumiko Hongo ◽  
Takanobu Onoda ◽  
Yusuke Kita ◽  
Yukio Ishihara ◽  
...  

AbstractCentral venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsion, including the device type. A total of 308 consecutive patients with initial CVP implantation between January 2011 and December 2017 were retrospectively reviewed, and the association of clinical features with CVP-related complications were analyzed. Intraoperative and postoperative complications occurred in 11 (3.6%) and 39 (12.7%) patients, respectively. The overall rate of CVP availability at six months was 91.4%. Malignancy and 2-Methacryloyloxyethyl phosphorylcholine (MPC) polymer-coated catheter use were negatively associated with the incidence of CVP infections. Accordingly, malignancy and MPC polymer-coated catheter use were independent predictors for lower CVP evulsion rate (odds ratio, 0.23 and 0.18, respectively). Furthermore, both factors were significantly associated with longer CVP availability (hazard ratio, 0.24 and 0.27, respectively). This retrospective study identified factors associated with CVP-related complications and long-term CVP availability. Notably, MPC polymer-coated catheter use was significantly associated with a lower rate of CVP infection and longer CVP availability, suggesting the preventive effect of MPC coating on CVP infection.


2008 ◽  
Vol 126 (6) ◽  
pp. 347-349 ◽  
Author(s):  
Rodrigo Chaves Ribeiro ◽  
Áurea Cristina Ferreira Monteiro ◽  
Quirino Cavalcante Menezes ◽  
Sérgio Tomaz Schettini ◽  
Sonia Maria Rossi Vianna

CONTEXT AND OBJECTIVE: Long-term totally implantable catheters (e.g. Port-a-Cath®) are frequently used for long-term venous access in children with cancer. The use of this type of catheter is associated with complications such as infection, extrusion, extravasation and thrombosis. Embolism of catheter fragments is a rare complication, but has potential for morbidity. The aim here was to report on two cases in which embolism of fragments of a long-term totally implantable catheter occurred. DESIGN AND SETTING: Case series study at Hospital do Servidor Público Estadual, São Paulo. METHODS: Retrospective review of catheter embolism in oncological pediatric patients with long-term totally implantable catheters. RESULTS: The first patient was a 3-year-old girl diagnosed with stage IV Wilms' tumor. Treatment was started with the introduction of a totally implantable catheter through the subclavian vein. At the time of removal, it was realized that the catheter had fractured inside the heart. An endovascular procedure was necessary to remove the fragment. The second case was a boy diagnosed with stage II Wilms' tumor at the age of two years. At the time of removal, it was noticed that the catheter had disconnected from the reservoir and an endovascular procedure was also necessary to remove the embolized catheter. CONCLUSION: Embolism of fragments of totally implantable catheters is a rare complication that needs to be recognized even in asymptomatic patients.


2009 ◽  
Vol 4 (2) ◽  
pp. 456-460 ◽  
Author(s):  
Raheela Rehman ◽  
Rebecca J. Schmidt ◽  
Alvin H. Moss

Sign in / Sign up

Export Citation Format

Share Document