scholarly journals A low-cost, wireless near-infrared spectroscopy device detects the presence of lower extremity atherosclerosis as measured by computed tomographic angiography and characterizes walking impairment in peripheral artery disease

2020 ◽  
Vol 71 (3) ◽  
pp. 946-957 ◽  
Author(s):  
Matthew A. Fuglestad ◽  
Hernan Hernandez ◽  
Yue Gao ◽  
Henamari Ybay ◽  
Molly N. Schieber ◽  
...  
Vascular ◽  
2021 ◽  
pp. 170853812110251
Author(s):  
Tomas Baltrūnas ◽  
Valerija Mosenko ◽  
Artūras Mackevičius ◽  
Vilius Dambrauskas ◽  
Ingrida Ašakienė ◽  
...  

Background Peripheral arterial disease is a stenosis or occlusion of peripheral arteries that results in compromised blood flow and muscle ischemia. The available diagnostic methods are mostly used to measure and visualize blood flow and are not useful in the evaluation of perfusion, especially in diabetic patients, which is now considered to be a research priority by most of the vascular societies around the world as this is still a relatively poorly studied phenomenon. Objective The aim of this review is to explore the clinical significance of muscle tissue oxygenation monitoring in lower-extremity peripheral artery disease diagnosis using the near-infrared spectroscopy method. Methods A systematic search in PubMed, CINAHL, and Cochrane databases was performed to identify clinical near-infrared spectroscopy (NIRS) studies in English and Russian, published until September 2019, involving muscle tissue oxygenation in peripheral arterial disease (PAD). The manuscripts were reviewed by two researchers independently and scored on the quality of the research using MINORS criteria. Results After screening 443 manuscripts, 23 studies ( n = 1580) were included. NIRS-evaluated recovery time seems to be more accurate than ankle-brachial index in diabetic patients to differentiate between moderate and severe claudication. Consistent findings across all the included studies showed that both the oxygenation and deoxygenation rates as well as the recovery times varied from patient to patient and therefore were not suitable for standardization. Conclusions The clinical relevance of routine use of NIRS to diagnose PAD is unproven; therefore, its use is not currently part of standard-of-care for patients with PAD since the absolute values seem to vary significantly, depending on the outside conditions. More data need to be provided on the possible use of NIRS monitoring intraoperatively where the conditions can be more controlled.


Radiographics ◽  
2017 ◽  
Vol 37 (1) ◽  
pp. 363-364
Author(s):  
Vincent Jaquinandi ◽  
Adrien Kaladji ◽  
Alexis Le Faucheur ◽  
Mathieu Léderlin ◽  
Guillaume Mahé

2020 ◽  
Vol 34 (03) ◽  
pp. 145-151
Author(s):  
Shimpei Ono ◽  
Hiroyuki Ohi ◽  
Rei Ogawa

AbstractSince propeller flaps are elevated as island flaps and most often nourished by a single perforator nearby the defect, it is challenging to change the flap design intraoperatively when a reliable perforator cannot be found where expected to exist. Thus, accurate preoperative mapping of perforators is essential in the safe planning of propeller flaps. Various methods have been reported so far: (1) handheld acoustic Doppler sonography (ADS), (2) color duplex sonography (CDS), (3) perforator computed tomographic angiography (P-CTA), and (4) magnetic resonance angiography (MRA). To facilitate the preoperative perforator assessment, P-CTA is currently considered as the gold standard imaging tool in revealing the three-dimensional anatomical details of perforators precisely. Nevertheless, ADS remains the most widely used tool due to its low cost, faster learning, and ease of use despite an undesirable number of false-positive results. CDS can provide hemodynamic characteristics of the perforator and is a valid and safer alternative particularly in patients in whom ionizing radiation and/or contrast exposure should be limited. Although MRA is less accurate in detecting smaller perforators of caliber less than 1.0 mm and the intramuscular course of perforators at the present time, MRA is expected to improve in the future due to the recent developments in technology, making it as accurate as P-CTA. Moreover, it provides the advantage of being radiation-free with fewer contrast reactions.


Sign in / Sign up

Export Citation Format

Share Document