scholarly journals Fluid-structure interaction modeling of blood flow in the pulmonary arteries using the unified continuum and variational multiscale formulation

2020 ◽  
Vol 107 ◽  
pp. 103556 ◽  
Author(s):  
Ju Liu ◽  
Weiguang Yang ◽  
Ingrid S. Lan ◽  
Alison L. Marsden
Perfusion ◽  
2021 ◽  
pp. 026765912199854
Author(s):  
Mohammad Javad Ghasemi Pour ◽  
Kamran Hassani ◽  
Morteza Khayat ◽  
Shahram Etemadi Haghighi

Background and objectives: Fluid structure interaction (FSI) is defined as interaction of the structures with contacting fluids. The aortic valve experiences the interaction with blood flow in systolic phase. In this study, we have tried to predict the hemodynamics of blood flow through a normal and stenotic aortic valve in two relaxation and exercise conditions using a three-dimensional FSI method. Methods: The aorta valve was modeled as a three-dimensional geometry including a normal model and two others with 25% and 50% stenosis. The geometry of the aortic valve was extracted from CT images and the models were generated by MMIMCS software and then they were implemented in ANSYS software. The pulsatile flow rate was used for all cases and the numerical simulations were conducted based on a time-dependent domain. Results: The obtained results including the velocity, pressure, and shear stress contours in different systolic time sequences were explained and discussed. The maximum blood flow velocity in relaxation phase was obtained 1.62 m/s (normal valve), 3.78 m/s (25% stenosed valve), and 4.73 m/s (50% stenosed valve). In exercise condition, the maximum velocities are 2.86, 4.32, and 5.42 m/s respectively. The maximum blood pressure in relaxation phase was calculated 111.45 mmHg (normal), 148.66 mmHg (25% stenosed), and 164.21 mmHg (50% stenosed). However, the calculated values in exercise situation were 129.57, 163.58, and 191.26 mmHg. The validation of the predicted results was also conducted using existing literature. Conclusions: We believe that such model are useful tools for biomechanical experts. The further studies should be done using experimental data and the data are implemented on the boundary conditions for better comparison of the results.


2009 ◽  
Vol 46 (1) ◽  
pp. 43-52 ◽  
Author(s):  
Ryo Torii ◽  
Marie Oshima ◽  
Toshio Kobayashi ◽  
Kiyoshi Takagi ◽  
Tayfun E. Tezduyar

2021 ◽  
Vol 11 (2) ◽  
pp. 13-16
Author(s):  
Artur Ovsepyan ◽  
Alexander Smirnov ◽  
Sergey Dydykin ◽  
Yuriy Vasil'ev ◽  
Evgeniy Trunin ◽  
...  

The interaction of the blood flow with the aorta is a complex dynamic event described in biomechanics as the Fluid-structure interaction. In this study we’ve developed a method for creation of a personalized 3D dynamic model of the aortic bulb and arch for the prediction of its mechanical behavior using FSI-analysis. We found that the accuracy of predicting geometric aortic deformities based on FSI modeling is on average 92%.