Aortic valve perforation following Amplatzer vascular plug device closure of ‘pulsatile’ Fontan

2017 ◽  
Vol 47 ◽  
pp. 84-86
Author(s):  
Nitin Madan ◽  
Harinder R. Singh ◽  
Muhammad A. Mumtaz ◽  
Srinath Gowda
2015 ◽  
Vol 67 (5) ◽  
pp. 455-458 ◽  
Author(s):  
Gopalan Nair Rajesh ◽  
Kalathingathodika Sajeer ◽  
Anishkumar Nair ◽  
Vellani Haridasan ◽  
Chakanalil Govindan Sajeev ◽  
...  

2012 ◽  
Vol 23 (5) ◽  
pp. 755-758 ◽  
Author(s):  
Eapen Thomas ◽  
Salim Maskari ◽  
Abdullah Farqani

AbstractAortico-left ventricular tunnel is a rare congenital heart defect. Reports on successful device closure of these defects are scarce. We are reporting the first case of device closure of aortico-left ventricular tunnel using an Amplatzer vascular plug III.


2020 ◽  
Vol 41 (4) ◽  
pp. 703-708
Author(s):  
Melissa K. Webb ◽  
Lyndsey E. Hunter ◽  
Theodore R. Kremer ◽  
Charles B. Huddleston ◽  
Andrew C. Fiore ◽  
...  

2021 ◽  
pp. 1-3
Author(s):  
Samir Shakya ◽  
Anita Saxena ◽  
Sivasubramanian Ramakrishnan

Abstract Abernethy malformation is a rare entity. We report a 5-year-old boy presenting with severe pulmonary hypertension in whom Abernethy malformation and inferior caval vein interruption were diagnosed by CT angiography. In addition, the iliac veins were thrombosed with multiple venous collateral drainage. This abnormal venous anatomy caused difficulty in device closure of the Abernethy malformation, which was successfully closed using a vascular plug.


Vascular ◽  
2021 ◽  
pp. 170853812110251
Author(s):  
Umberto M Bracale ◽  
Anna Petrone ◽  
Michele Provenzano ◽  
Nicola Ielapi ◽  
Liborio Ferrante ◽  
...  

Objectives The Amplatzer Vascular Plug (AVP) is a vascular occlusion device designed to provide optimal embolization in several fields of the endovascular surgery. A full literature review was conducted to analyze AVPs in comparison with coils for the prevention of endoleaks during endovascular abdominal aortic aneurysm repair. Methods A systematic review was designed under PRISMA statement guidelines for systematic reviews and meta-analyses. The results were updated with a subsequent electronic search using Medline and Scopus databases up to December 2019. Results Eighteen articles making this comparison were found. In 79.7% of the cases, the target vessel was the internal iliac artery; in 1.6%, the common iliac artery; and in 16.7%, the inferior mesenteric artery. Risk of complications (buttock claudication, groin hematoma, endoleaks, and erectile dysfunction) after AVP was low. A cost comparison revealed that the mean cost for coils was around US$2262, while the average cost for the AVP was US$310. Conclusions The AVP is an effective and safe device for occluding peripheral vessels, proved to have lower complications rates. Compared with coil embolization, the AVP technique is potentially associated with lower procedural costs.


2021 ◽  
pp. 1-3
Author(s):  
Ahmet Vedat Kavurt ◽  
İbrahim Ece ◽  
Denizhan Bağrul

Abstract Acquired and congenital left ventricular to right atrial communication is rare, but nowadays, the frequency of the iatrogenic subgroup is increasing. Successful transcatheter closure of these defects with different devices has been reported. Herein, we presented successful closure of left ventricular to right atrial communication with Amplatzer Duct Occluder 2 after attempting to close with a failed Amplatzer Vascular Plug II device in a 7-year-old girl. This report supports that transcatheter closure of iatrogenic Gerbode defect with Amplatzer Duct Occluder 2 device is safe and effective.


2016 ◽  
Vol 22 (4) ◽  
pp. 358-364 ◽  
Author(s):  
Ahmed Kamel Abdel Aal ◽  
Rafik Mohamed Ibrahim ◽  
Amr Soliman Moustafa ◽  
Maysoon Farouk Hamed ◽  
Souheil Saddekni

Vascular ◽  
2009 ◽  
Vol 17 (1) ◽  
pp. 40-43 ◽  
Author(s):  
J. E. Campbell ◽  
C. Davis ◽  
B. P. DeFade ◽  
J. P. Tierney ◽  
P. A. Stone

Sign in / Sign up

Export Citation Format

Share Document