Fading study and readout optimization for routinely use of LiF:Mg,Ti thermoluminescent detectors for personal dosimetry

2020 ◽  
Vol 135 ◽  
pp. 106342 ◽  
Author(s):  
D. Sorger ◽  
H. Stadtmann ◽  
W. Sprengel
2008 ◽  
Vol 47 (04) ◽  
pp. 175-177 ◽  
Author(s):  
J. Dolezal

SummaryAim: To assess a radiation exposure and the quality of radiation protection concerning a nuclear medicine staff at our department as a six-year retrospective study. Therapeutic radionuclides such as 131I, 153Sm, 186Re, 32P, 90Y and diagnostic ones as a 99mTc, 201Tl, 67Ga, 111In were used. Material, method: The effective dose was evaluated in the period of 2001–2006 for nuclear medicine physicians (n = 5), technologists (n = 9) and radiopharmacists (n = 2). A personnel film dosimeter and thermoluminescent ring dosimeter for measuring (1-month periods) the personal dose equivalent Hp(10) and Hp(0,07) were used by nuclear medicine workers. The wearing of dosimeters was obligatory within the framework of a nationwide service for personal dosimetry. The total administered activity of all radionuclides during these six years at our department was 17,779 GBq (99mTc 14 708 GBq, 131I 2490 GBq, others 581 GBq). The administered activity of 99mTc was similar, but the administered activity of 131I in 2006 increased by 200%, as compared with the year 2001. Results: The mean and one standard deviation (SD) of the personal annual effective dose (mSv) for nuclear medicine physicians was 1.9 ± 0.6, 1.8 ± 0.8, 1.2 ± 0.8, 1.4 ± 0.8, 1.3 ± 0.6, 0.8 ± 0.4 and for nuclear medicine technologists was 1.9 ± 0.8, 1.7 ± 1.4, 1.0 ± 1.0, 1.1 ± 1.2, 0.9 ± 0.4 and 0.7 ± 0.2 in 2001, 2002, 2003, 2004, 2005 and 2006, respectively. The mean (n = 2, estimate of SD makes little sense) of the personal annual effective dose (mSv) for radiopharmacists was 3.2, 1.8, 0.6, 1.3, 0.6 and 0.3. Although the administered activity of 131I increased, the mean personal effective dose per year decreased during the six years. Conclusion: In all three professional groups of nuclear medicine workers a decreasing radiation exposure was found, although the administered activity of 131I increased during this six-year period. Our observations suggest successful radiation protection measures at our department.


Crystals ◽  
2020 ◽  
Vol 10 (3) ◽  
pp. 189 ◽  
Author(s):  
Sandra Witkiewicz-Lukaszek ◽  
Anna Mrozik ◽  
Vitalii Gorbenko ◽  
Tetiana Zorenko ◽  
Pawel Bilski ◽  
...  

This work is dedicated to the development of new types of composite thermoluminescent (TL) detectors for simultaneous registration of the different components of ionization radiation based on the single crystalline films (SCFs) of Ce3+-doped Lu3−xGdxAl5O12:Ce (x = 0–1.5) garnet and Y3Al5O12:Ce (YAG:Ce) substrates using the liquid phase epitaxy (LPE) growth method. For this purpose, the TL properties of the mentioned epitaxial structures were examined in Risø TL/OSL-DA-20 reader under excitation by α- and β-particles from 242Am and 90Sr-90Y sources. We have shown that the cation engineering of SCF content can result in more significant separation of the TL glow curves of SCFs and substrates under α- and β-particle excitations in comparison with the prototype of such composite detectors based on the Lu3Al5O12:Ce (LuAG:Ce)/YAG:Ce epitaxial structure. Specifically, the difference between the TL glow curves of Lu1.5Gd1.5Al5O12:Ce SCFs and YAG:Ce substrates increases up to 120 K in comparison with a respective value of 80 degrees in the prototype based on the LuAG:Ce/YAG:Ce epitaxial structure. Therefore, the LPE-grown epitaxial structures containing Lu1.5Gd1.5Al5O12:Ce SCFs and Ce3+-doped YAG:Ce substrate can be successfully applied for simultaneous registration of α- and β-particles in mixed fluxes of ionization radiation.


2017 ◽  
Vol 49 (7) ◽  
pp. 922-927 ◽  
Author(s):  
LLA Price ◽  
A Lyachev

Performance characterisations were carried out before and after a modification to the optics of the Condor Instruments’ ActTrust light and activity data loggers to improve the spectral performance for measuring melanopic-weighted irradiance in non-visual studies. The results confirm the intended improvement, so that the device provides the best-known single-sensor match to the melanopic response. In addition, the device includes a separate sensor which remained well-matched for illuminance logging.


2006 ◽  
Vol 120 (1-4) ◽  
pp. 312-315 ◽  
Author(s):  
B. Morelli ◽  
F. Mariotti ◽  
E. Fantuzzi
Keyword(s):  

1985 ◽  
Vol 10 (1-4) ◽  
pp. 43-57 ◽  
Author(s):  
C.M. Eisenhauer ◽  
J.B. Hunt ◽  
R.B. Schwartz