Performance Analysis of Integrated Solar Heat Pump VRF System for the Low Energy Building in Mediterranean Island

Author(s):  
Hooman Azad Gilani ◽  
Siamak Hoseinzadeh ◽  
Hirou Karimi ◽  
Ako Karimi ◽  
Amir Hassanzadeh ◽  
...  
Solar Energy ◽  
2021 ◽  
Vol 221 ◽  
pp. 10-29
Author(s):  
Bo Xiang ◽  
Yasheng Ji ◽  
Yanping Yuan ◽  
Chao Zeng ◽  
Xiaoling Cao ◽  
...  

2016 ◽  
Vol 108 ◽  
pp. 181-191 ◽  
Author(s):  
N.N. Shah ◽  
M.J. Huang ◽  
N.J. Hewitt

Author(s):  
Srinivas Vanapalli ◽  
M. E. H. Tijani ◽  
Simon Spoelstra

Domestic heating contributes to a significant amount of energy usage in the Netherlands. Due to scare energy resources, attention to develop new and efficient technologies is increasing. At ECN, a burner driven heat pump employing thermoacoustic technology is being developed for possible applications in households and offices. The desired temperature lift is from 10 °C to 80 °C. As a first step the heat pump is driven by a linear motor. Measurements and performance analysis of the heat pump are presented in this paper. The heat pump has a coefficient of performance which is the ratio of heat produced to the work input of 1.38 when operating between 10 °C to 80 °C. The performance relative to maximum possible Carnot value is 26.5%.