scholarly journals Evaluation of Gafchromic EBT2 film for the measurement of anisotropy function for high-dose-rate 192Ir brachytherapy source with respect to thermoluminescent dosimetry

2011 ◽  
Vol 16 (1) ◽  
pp. 14-20 ◽  
Author(s):  
Satish C. Uniyal ◽  
Umesh C. Naithani ◽  
Sunil D. Sharma
2004 ◽  
Vol 49 (17) ◽  
pp. 4065-4072 ◽  
Author(s):  
S D Sharma ◽  
C Bianchi ◽  
L Conte ◽  
R Novario ◽  
B C Bhatt

2016 ◽  
Vol 39 (2) ◽  
pp. 591-591 ◽  
Author(s):  
Akbar Sarabiasl ◽  
Navid Ayoobian ◽  
Hossein Poorbaygi ◽  
Iraj Jabbari ◽  
Mohammad Reza Javanshir

2008 ◽  
Vol 35 (6Part1) ◽  
pp. 2279-2285 ◽  
Author(s):  
Kent A. Gifford ◽  
Michael J. Price ◽  
John L. Horton ◽  
Todd A. Wareing ◽  
Firas Mourtada

1998 ◽  
Vol 25 (10) ◽  
pp. 1975-1984 ◽  
Author(s):  
P. Karaiskos ◽  
A. Angelopoulos ◽  
L. Sakelliou ◽  
P. Sandilos ◽  
C. Antypas ◽  
...  

2013 ◽  
Vol 106 ◽  
pp. S71-S72
Author(s):  
R.D. Franich ◽  
R.L. Smith ◽  
M.L. Taylor ◽  
A. Haworth ◽  
L.N. McDermott ◽  
...  

Author(s):  
Tania Afroz ◽  
Pretam K. Das ◽  
S. I. Chawdhury ◽  
Shudeb K. Roy

Aim of this work is to calibrate the high dose rate (HDR) brachytherapy source 60Co. The radioactive source calibration is a very important part of the quality assurance program for dosimetry of brachytherapy source. The goal of this project is the calibration of HDR Brachytherapy source in radiation therapy is the measurement of the air kerma rate which required actual dose to deliver. The source calibration is an essential part of the quality assurance program for dosimetry of brachytherapy source. This research will help the patient who is involving brachytherapy treatment. HDR brachytherapy source 60Co is inserted directly or in close to the tumor. Most commonly using method for calibration of HDR brachytherapy source 60CO is well type ionization chamber. Calibration of the radioactive source 60Co brachytherapy source is very important for the treatment of cancer patient. We have got the variation between RAKR from TPS and measured Air Kerma Rate of 60Co brachytherapy source are 3.2% and 3.04% and which give very good agreement with the Air Kerma Rate (RAKR) is 5% (from BEBIG protocol, Germany). So, our results were satisfied for brachytherapy treatment. From these results, it must be concluded that, 60Co brachytherapy source is suitable for brachytherapy cancer treatment. It is very difficult to calculate treatment deliver dose without calibrating AKR of HDR brachytherapy source. It is very important to verify the calculated Air Kerma Rate by TPS Air Kerma Rate.