Improving broadband ultrasound attenuation assessment in cancellous bone by mitigating the influence of cortical bone: Phantom and in-vitro study

Ultrasonics ◽  
2019 ◽  
Vol 94 ◽  
pp. 382-390 ◽  
Author(s):  
Yuriy Tasinkevych ◽  
Katarzyna Falińska ◽  
Peter A. Lewin ◽  
Jerzy Litniewski
2010 ◽  
Vol 128 (5) ◽  
pp. 3181-3189 ◽  
Author(s):  
Katsunori Mizuno ◽  
Hiroki Somiya ◽  
Tomohiro Kubo ◽  
Mami Matsukawa ◽  
Takahiko Otani ◽  
...  

1993 ◽  
Vol 54 (1) ◽  
pp. 46-51 ◽  
Author(s):  
D.M.K.S.Kaulesar Sukul ◽  
E.J. Johannes ◽  
E.G.J.M. Pierik ◽  
G.J.W.M. van Eijck ◽  
M.J.E. Kristelijn

2013 ◽  
Vol 07 (S 01) ◽  
pp. S083-S088 ◽  
Author(s):  
Murat Tozlu ◽  
Didem Nalbantgil ◽  
Fulya Ozdemir

ABSTRACT Objective: An appliance was designed to increase the cortical bone surface contact area of miniscrew implants (MSIs). The purpose of this in vitro study was to evaluate the effects of this appliance on the anchorage force resistance and the stability of orthodontic MSIs. Materials and Methods: A total of 48 MSIs were placed into bone specimens prepared from the ilium of bovines. Half were placed with the newly designed apparatus and half were placed conventionally. All the specimens were subjected to tangential force loading perpendicular to the MSI with lateral displacement of 0.6 mm, using an Instron Universal Testing machine. The maximum removal torque of each tested specimen was also recorded. Both study and control groups were divided into two subgroups based on whether they had thin and thick cortical bone. Results: The test group had statistically higher force anchorage resistance and maximum insertion torque values than the control group (p < 0.001). The results were found to be more significant in cases in which the cortical bone was thin (p < 0.001). Conclusions: Within the limits of this in vitro study, the present findings suggest that the newly designed apparatus might have a favorable effect on MSI stability in patients presenting with thin cortical bone. Clinical studies are necessary to confirm the results that were observed in vitro.


Bone ◽  
2007 ◽  
Vol 40 (3) ◽  
pp. 656-661 ◽  
Author(s):  
S.P. Dodd ◽  
J.L. Cunningham ◽  
A.W. Miles ◽  
S. Gheduzzi ◽  
V.F. Humphrey

2009 ◽  
Vol 125 (5) ◽  
pp. 3460 ◽  
Author(s):  
Katsunori Mizuno ◽  
Mami Matsukawa ◽  
Takahiko Otani ◽  
Pascal Laugier ◽  
Frédéric Padilla

2018 ◽  
Vol 4 (3) ◽  
pp. 035027 ◽  
Author(s):  
Mohammad Hassan Ramezan Zadeh ◽  
Majid Seifi ◽  
Maryam Abdolrahimi ◽  
Mahvash Hadavi

Sign in / Sign up

Export Citation Format

Share Document