cortical bone
Recently Published Documents


TOTAL DOCUMENTS

4779
(FIVE YEARS 896)

H-INDEX

118
(FIVE YEARS 10)

2022 ◽  
Vol 12 (2) ◽  
pp. 798
Author(s):  
Omrane Kadri ◽  
Abdulrahman Alfuraih

Tissue equivalent materials (TEM) are frequently used in research as a means to determine the delivered dose to patients undergoing various therapeutic procedures. They are used in routine quality assurance and quality control procedures in diagnostic and therapeutic physics. However, very few materials that are tissue equivalent have been developed for use in research at the low photon energies involved in diagnosis radiology. The objective of this study is to describe a series of TEMs designed to radiographically imitate human tissue at diagnostic photon energies. TEMs for adipose, cortical bone, fat, lung, and muscle tissues were investigated in terms of energy absorption and exposure buildup factors for photon energy range 15–150 keV and for penetration depths up to 40 mean free path. BUF was computed based on GP-fitting method. Moreover, we also compared some radiological properties, including the total attenuation and the energy-absorption attenuation, the effective atomic number, and the CT number at 30, 100, and 120 kVp. We found that SB3, Glycerol trioleate, and MS15 perfectly mimic cortical bone, fat, and muscle tissues, respectively. Additionally, AP6 and Stracey latex are good TEM for adipose and lung tissues, respectively. The results of this work should be useful in radiation diagnosis and dosimetry applications for the large physician researcher community.


2022 ◽  
Vol 8 ◽  
Author(s):  
Pengcheng Liu ◽  
Joanna Xi Xiao ◽  
Chen Zhao ◽  
Xiaodong Li ◽  
Guantong Sun ◽  
...  

Background: It is important to select appropriate screws in orthopedic surgeries, as excessively long or too short a screw may results failure of the surgeries. This study explored factors that affect the accuracy of measurements in terms of the experience of the surgeons, passage of drilled holes and different depth gauges.Methods: Holes were drilled into fresh porcine femurs with skin in three passages, straight drilling through the metaphysis, straight drilling through the diaphysis, and angled drilling through the diaphysis. Surgeons with different surgical experiences measured the holes with the same depth gauge and using a vernier caliper as gold standard. The length of selected screws, and the time each surgeon spent were recorded. The measurement accuracy was compared based on the experiences of the surgeons and the passage of drilled holes. Further, parameters of depth gauges and 12-mm cortical bone screws from five different manufacturers were measured.Results: A total of 13 surgeons participated in 585 measurements in this study, and each surgeon completed 45 measurements. For the surgeons in the senior, intermediate, and junior groups, the average time spent in measurements was 689, 833, and 785 s with an accuracy of 57.0, 42.2, and 31.5%, respectively. The accuracy and measurement efficiency were significantly different among the groups of surgeons (P < 0.001). The accuracy of measurements was 45.1% for straight metaphyseal drilling, 43.6% for straight diaphyseal drilling, and 33.3% for angled diaphyseal drilling (P = 0.036). Parameters of depth gauges and screws varied among different manufacturers.Conclusion: Both observer factor and objective factors could affect the accuracy of depth gauge measurement. Increased surgeon's experience was associated with improvements in the accuracy rate and measurement efficiency of drilled holes based on the depth gauge. The accuracy rate varied with hole passages, being the lowest for angled drilled holes.


2022 ◽  
Vol 2022 ◽  
pp. 1-7
Author(s):  
Yue Li ◽  
Yuxiang Chen ◽  
Yuzeng Liu ◽  
Yong Hai ◽  
Xinuo Zhang ◽  
...  

In this prospective cohort study, we aimed to determine the surgical and adjacent segment changes in paraspinal muscles and facet joints in patients with lumbar spinal stenosis after minimally invasive posterior lumbar interbody fusion (PLIF) using the cortical bone trajectory (CBT) technique. We enrolled 30 consecutive patients who underwent the single-level CBT technique between October 2017 and October 2018. We evaluated preoperative and 1-month, 3-month, 6-month, and 1-year postoperative clinical data including Visual Analogue Scale (VAS) scores and Oswestry Disability Index (ODI). Magnetic resonance imaging (MRI) was performed a year after surgery. The erector spinae (ES) muscle area, volume, and fat infiltration (FI) on the surgical and adjacent segments were evaluated using the thresholding method, and the degree of adjacent facet joint degeneration was calculated using the Weishaupt scale. FI rate was graded using the Kjaer method. All patients underwent a 12-month follow-up. The VAS and ODI scores significantly improved after surgery in all patients. No patient showed degeneration of the adjacent facet joints ( P > 0.05 ) during the 1-year follow-up postoperation. There was no significant difference in ES muscle volume, area, and FI on the surgical and adjacent segments ( P > 0.05 ). The FI rate of the upper ES muscles increased postoperatively ( P < 0.05 ); however, there were no significant changes in FI rate of the lower ES muscles. Patients with lumbar spinal stenosis could obtain satisfactory short-term clinical outcomes via minimally invasive PLIF using the CBT technique. Moreover, this technique may reduce the impact on the paravertebral muscles, especially the ES muscle, and the adjacent facet joints.


Author(s):  
Ebrahim Maghami ◽  
Jason P. Moore ◽  
Timothy O. Josephson ◽  
Ahmad R. Najafi

PLoS ONE ◽  
2022 ◽  
Vol 17 (1) ◽  
pp. e0260924
Author(s):  
Kyong Young Kim ◽  
Kyoung Min Kim

Bone quality is a critical factor that, along with bone quantity, determines bone strength. Image-based parameters are used for assessing bone quality non-invasively. The trabecular bone score (TBS) is used to assess quality of trabecular bone and femur geometry for cortical bone. Little is known about the associations between these two bone quality parameters and whether they show differences in the relationships with age and body mass index (BMI). We investigated the associations between the trabecular bone score (TBS) and femur cortical geometry. Areal bone mineral density (BMD) was assessed using dual energy X-ray absorptiometry (DXA) and the TBS was assessed using iNsight software and, femur geometry using APEX (Hologic). A total of 452 men and 517 women aged 50 years and older with no medical history of a condition affecting bone metabolism were included. Z-scores for TBS and cortical thickness were calculated using the age-specific mean and SD for each parameter. A ‘discrepancy group’ was defined as patients whose absolute Z-score difference between TBS and cortical thickness was > 1 point. TBS and cortical thickness correlated negatively with age both in men and women, but the associations were stronger in women. Regarding the associations with BMI, TBS provided significant negative correlation with BMI in the range of BMI > 25 kg/m2. By contrast, cortical thickness correlated positively with BMI for all BMI ranges. These bone quality-related parameters, TBS and cortical thickness, significantly correlated, but discordance between these two parameters was observed in about one-third of the men and women (32.7% and 33.4%, respectively). Conclusively, image-based bone quality parameters for trabecular and cortical bone exhibit both similarities and differences in terms of their associations with age and BMI. These different profiles in TBS and FN cortical thickness might results in different risk profiles for the vertebral fractures or hip fractures in a certain percentage of people.


2022 ◽  
Author(s):  
Kotaro Ito ◽  
Go Itakura ◽  
Hirotaka Muraoka ◽  
Naohisa Hirahara ◽  
Eri Sawada ◽  
...  

2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Wencke Lehnert ◽  
Patrick J. Riss ◽  
Ana Hurtado de Mendoza ◽  
Sandra Lopez ◽  
Gonzalo Fernandez ◽  
...  

Abstract Purpose [18F]PR04.MZ is a new PET imaging agent for dopamine transporters, providing excellent image quality and allowing for the evaluation of patients with movement disorders such as Parkinson’s disease. The objective of this study was to evaluate the biodistribution and radiation dosimetry of [18F]PR04.MZ by serial PET imaging. Methods Six healthy subjects (n = 3 males, n = 3 females) were enrolled in this study. A series of 14 whole-body PET/CT scans were acquired until 5.5 h post-injection of 200 ± 11 MBq of [18F]PR04.MZ. After rigid co-registration, volumes of interest were outlined either on CT or PET images. Time-integrated activity coefficients were calculated for selected source organs. Organ absorbed doses, and the effective dose were calculated using IDAC-Dose 2.1. Results Physiological uptake of [18F]PR04.MZ was mainly observed in the striatum, brain, liver, gall bladder, intestine, red marrow and cortical bone. [18F]PR04.MZ was primarily excreted via hepatobiliary clearance and, to a lower extent, via renal clearance. The normalized absorbed doses were highest in gall bladder wall (32.2 ± 6.4 µGy/MBq), urinary bladder wall (27.2 ± 4.5 µGy/MBq), red marrow (26.5 ± 1.4 µGy/MBq), cortical bone surface (26.3 ± 2.5 µGy/MBq), liver (22.5 ± 1.8 µGy/MBq) and kidneys (21.8 ± 1.1 µGy/MBq). The effective dose according to ICRP 60 and 103 was 16.3 ± 1.1 and 16.6 ± 1.5 µSv/MBq, respectively. Conclusion [18F]PR04.MZ has a favourable dosimetry profile, comparable to those of other 18F-labelled PET tracers, and is suitable for larger clinical applications. Trial registration CEC SSM Oriente, Santiago, Chile, permit 20140520.


2022 ◽  
pp. 030157422110607
Author(s):  
Arun Kumar Dasari ◽  
Madhukar Reddy Rachala ◽  
Kaladhar Reddy Aileni

Orthodontic management of ectopic canines is quite challenging and time consuming due to the presence of thin buccal cortical bone. Sectional mechanics provide distal and extrusive force on canine but without any torque control. So, palatal root torquing during canine retraction is needed to increase the buccal cortical bone thickness and to avoid bone dehiscence and gingival recession. This article describes an innovative spring which provides 3-dimensional control by simultaneous retraction, extrusion, and torquing of ectopic canine.


Author(s):  
Ajay Kumar ◽  
Rajesh Ghosh

This paper comprehensively reviews the various experimental and numerical techniques, which were considered to determine the fracture characteristics of the cortical bone. This study also provides some recommendations along with the critical review, which would be beneficial for future research of fracture analysis of cortical bone. Cortical bone fractures due to sports activities, climbing, running, and engagement in transport or industrial accidents. Individuals having different diseases are also at high risk of cortical bone fracture. It has been observed that osteon orientation influences cortical bone fracture toughness and fracture mechanisms. Apart from this, recent studies indicate that fracture parameters of cortical bone also depend on many factors such as age, sex, temperature, osteoporosis, orientation, location, loading condition, strain rate, and storage facility, etc. The cortical bone regains its fracture toughness due to various toughening mechanisms. Owing to these factors, several experimental, clinical, and numerical investigations have been carried out to determine the fracture parameters of the cortical bone. Cortical bone is the dense outer surface of the bone and contributes to 80%–82% of the skeleton mass. Cortical bone experiences load far exceeding body weight due to muscle contraction and the dynamics of motion. It is very important to know the fracture pattern, direction of fracture, location of the fracture, and toughening mechanism of cortical bone. A basic understanding of the different factors that affect the fracture parameters and fracture mechanisms of the cortical bone is necessary to prevent the failure and fracture of cortical bone. This review has summarized the advancement considered in the various experimental techniques and numerical methods to get complete information about the fracture mechanisms of cortical bone.


Sign in / Sign up

Export Citation Format

Share Document