scholarly journals Training peripheral vision to read: Boosting the speed of letter processing

2018 ◽  
Vol 152 ◽  
pp. 51-60 ◽  
Author(s):  
Deyue Yu ◽  
Gordon E. Legge ◽  
Gunther Wagoner ◽  
Susana T.L. Chung
Author(s):  
Thomas E. Moriarty ◽  
Andrew M. Junker ◽  
Don R. Price

2013 ◽  
Author(s):  
Jon Andoni Dunabeitia ◽  
Manuel Carreiras
Keyword(s):  

2013 ◽  
Vol 133 (1) ◽  
pp. 2-7 ◽  
Author(s):  
Kensuke Tobitani ◽  
Kunihito Kato ◽  
Kazuhiko Yamamoto
Keyword(s):  

2013 ◽  
Vol 17 (1) ◽  
pp. 125-141 ◽  
Author(s):  
Tânia Fernandes ◽  
Ana P. Vale ◽  
Bruno Martins ◽  
José Morais ◽  
Régine Kolinsky

2020 ◽  
pp. bjophthalmol-2020-317034
Author(s):  
Meghal Gagrani ◽  
Jideofor Ndulue ◽  
David Anderson ◽  
Sachin Kedar ◽  
Vikas Gulati ◽  
...  

PurposeGlaucoma patients with peripheral vision loss have in the past subjectively described their field loss as ‘blurred’ or ‘no vision compromise’. We developed an iPad app for patients to self-characterise perception within areas of glaucomatous visual field loss.MethodsTwelve glaucoma patients with visual acuity ≥20/40 in each eye, stable and reliable Humphrey Visual Field (HVF) over 2 years were enrolled. An iPad app (held at 33 cm) allowed subjects to modify ‘blur’ or ‘dimness’ to match their perception of a 2×2 m wall-mounted poster at 1 m distance. Subjects fixated at the centre of the poster (spanning 45° of field from centre). The output was degree of blur/dim: normal, mild and severe noted on the iPad image at the 54 retinal loci tested by the HVF 24-2 and was compared to threshold sensitivity values at these loci. Monocular (Right eye (OD), left eye (OS)) HVF responses were used to calculate an integrated binocular (OU) visual field index (VFI). All three data sets were analysed separately.Results36 HVF and iPad responses from 12 subjects (mean age 71±8.2y) were analysed. The mean VFI was 77% OD, 76% OS, 83% OU. The most common iPad response reported was normal followed by blur. No subject reported dim response. The mean HVF sensitivity threshold was significantly associated with the iPad response at the corresponding retinal loci (For OD, OS and OU, respectively (dB): normal: 23, 25, 27; mild blur: 18, 16, 22; severe blur: 9, 9, 11). On receiver operative characteristic (ROC) curve analysis, the HVF retinal sensitivity cut-off at which subjects reported blur was 23.4 OD, 23 OS and 23.3 OU (dB).ConclusionsGlaucoma subjects self-pictorialised their field defects as blur; never dim or black. Our innovation allows translation of HVF data to quantitatively characterise visual perception in patients with glaucomatous field defects.


Author(s):  
Jan Kremláček ◽  
Jana Nekolová ◽  
Markéta Středová ◽  
Jana Langrová ◽  
Jana Szanyi ◽  
...  

Abstract Background For patients with age-related macular degeneration (AMD), a special intraocular lens implantation partially compensates for the loss in the central part of the visual field. For six months, we evaluated changes in neurophysiological parameters in patients implanted with a “Scharioth macula lens” (SML; a center near high add + 10 D and peripheral plano carrier bifocal lens designed to be located between the iris and an artificial lens). Methods Fourteen patients (5 M, 9 F, 63–87 years) with dry AMD were examined prior to and at 3 days after, as well as 1, 2, and 6 months after, implantation using pattern-reversal, motion-onset, and cognitive evoked potentials, psychophysical tests evaluating distant and near visual acuity, and contrast sensitivity. Results Near visual acuity without an external aid was significantly better six months after implantation than before implantation (Jaeger table median (lower; upper quartile): 4 (1; 6) vs. 15 (13; 17)). Distant visual acuity was significantly altered between the pre- (0.7 (0.5; 0.8) logMAR) and last postimplantation visits (0.8 (0.7; 0.8) logMAR), which matched prolongation of the P100 peak time (147 (135; 151) ms vs. 161 (141; 166) ms) of 15 arc min pattern-reversal VEPs and N2 peak time (191.5 (186.5; 214.5) ms vs. 205 (187; 218) ms) of peripheral motion-onset VEPs. Conclusion SML implantation significantly improved near vision. We also observed a slight but significant decrease in distant and peripheral vision. The most efficient electrophysiological approach to test patients with SML was the peripheral motion-onset stimulation, which evoked repeatable and readable VEPs.


2011 ◽  
Vol 49 (7) ◽  
pp. 2013-2021 ◽  
Author(s):  
Simon Rigoulot ◽  
Fabien D’Hondt ◽  
Sabine Defoort-Dhellemmes ◽  
Pascal Despretz ◽  
Jacques Honoré ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document