Late (Five to Nine Years) Follow-Up After Balloon Dilation of Valvular Pulmonary Stenosis in Adults

1997 ◽  
Vol 80 (2) ◽  
pp. 240-242 ◽  
Author(s):  
Claudius H.J Teupe ◽  
Wolfram Burger ◽  
Rainer Schräder ◽  
Andreas M Zeiher
2021 ◽  
Author(s):  
Xuning Lu ◽  
Ping Wen ◽  
Yuhang Liu ◽  
Quanwei Zhu

Abstract BACKGROUND Transcatheter device closure of secundum atrial septal defect (ASD) with valvular pulmonary stenosis (PS) under fluoroscopy and/or transesophageal echocardiography (TEE) guidance is a mature technology. However, little study has focused on whether the technology can be guided totally by transthoracic echocardiography (TTE), even in children.METHODS Thirteen children with ASD combined with PS underwent transcatheter device closure totally guided by TTE at our cardiac center from March 2 016 to August 2 019. Percutaneous transcatheter pulmonary valvuloplasty was performed first and then transcatheter closure of the ASD uneventfully.RESULTS All cases were successfully treated with transcatheter balloon pulmonary valvuloplasty and closure of ASD respectively via femoral vein approach solely under TTE guidance. The mean defect size was 8.1±1.4 mm (range: 5.5-10 mm), the preoperative mean pressure gradient across pulmonary valve was 61.2±5.5 mmHg (range: 51-71 mmHg). The mean device size used was 11.1±1.9 mm (range: 8- 14 mm), the mean procedure time was 55.1±8.0 min (range: 45-71 min). There were no serious cardiovascular related complications. During the follow-up period (10 mon to 47mon), no arrhythmias device, thrombosis, residual fistulas or device frame fractures were detected. PS gradient had significant difference before and after procedure during the follow up (t=28.9, P =0.000).CONCLUSION Simultaneous transcatheter treatment for ASD complicated by PS in children under TTE guidance is an safe and effective therapeutic option.


2020 ◽  
Vol 30 (8) ◽  
pp. 1206-1208
Author(s):  
Sreekanth Yerram ◽  
Sunitha Aramalla ◽  
Srinivas Bhyravavajhala

AbstractAn atrial septal defect is a rare anomaly in patients with interrupted inferior vena cava, which renders the percutaneous intervention more complex; and hence, innovative approaches should be sought. Dextrocardia further complicates the procedure, and traditional atrial septal device deployment methods cannot be employed. We report a successful percutaneous secundum atrial septal defect closure by a novel deployment strategy along with balloon dilation of associated severe valvular pulmonary stenosis in a patient with dextrocardia and interrupted inferior vena cava.


QJM ◽  
2021 ◽  
Vol 114 (Supplement_1) ◽  
Author(s):  
M Hafez ◽  
H Kamel ◽  
Y Abdelrazik ◽  
H Attia

Abstract Aim and objectives The aim of this study was To correlate between 3D echocardiographic assessment of RV volumes and functions with invasive RV quantification by angiography in children with mainly valvular pulmonary stenosis undergoing balloon pulmonary valvuloplasty pre & post balloon dilation, to evaluate the immediate impact of relieving obstruction on RV volumes. Patients and Methods The study included 25 patients in the pediatric age group (up to 18 years old) with Pulmonary valve stenosis referred to our congenital and structural heart disease unit cardiology department in Ain shams university hospital for balloon pulmonary valvuloplasty. All patients were subjected to history taking, clinical examination and ECG recording. Then echocardiographic assessment by 2D and 3D was done to all patients pre and post BPV. All patients were subjected to have pre and post RV angiography for assessment of RV volumes and functions angiographically. Results The study included 25 patients,65% of patients were males and 44% were females, mean of age was 22.79 with range from 2 to 144 months There was statistically significant increase in 3D Echo RV quantification post BPV in comparison to 3D Echo RV quantification pre BPV with RV/EDV(p-value:0.001), RV/ESV(p-value:0.034), RV/SV(p-value:0.002), FAC %(p-value:0.014), TAPSE(p-value:0.001). Also,there was statistically significant increase in angiographic RV quantification post BPV in comparison to angiographic RV quantification pre BPV with EDV(p-value:<0.001), ESV(p-value:<0.001), SV(pvalue:<0.001) and EF %(p-value:<0.001). Conclusion 3DE RV volumes and function shows good correlation and agreement with invasive RV quantification by angiography in children with valvular pulmonary stenosis undergoing balloon pulmonary valvuloplasty.


2019 ◽  
Vol 23 (3) ◽  
pp. 363-368 ◽  
Author(s):  
Bing Zhou ◽  
Xiao-Chuan Wang ◽  
Jun-Yi Xiang ◽  
Ming-Zhao Zhang ◽  
Bo Li ◽  
...  

OBJECTIVEMechanical thrombectomy using a Solitaire stent retriever has been widely applied as a safe and effective method in adult acute ischemic stroke (AIS). However, due to the lack of data, the safety and effectiveness of mechanical thrombectomy using a Solitaire stent in pediatric AIS has not yet been verified. The purpose of this study was to explore the safety and effectiveness of mechanical thrombectomy using a Solitaire stent retriever for pediatric AIS.METHODSBetween January 2012 and December 2017, 7 cases of pediatric AIS were treated via mechanical thrombectomy using a Solitaire stent retriever. The clinical practice, imaging, and follow-up results were reviewed, and the data were summarized and analyzed.RESULTSThe ages of the 7 patients ranged from 7 to 14 years with an average age of 11.1 years. The preoperative National Institutes of Health Stroke Scale (NIHSS) scores ranged from 9 to 22 with an average of 15.4 points. A Solitaire stent retriever was used in all patients, averaging 1.7 applications of thrombectomy and combined balloon dilation in 2 cases. Grade 3 on the modified Thrombolysis In Cerebral Infarction scale of recanalization was achieved in 5 cases and grade 2b in 2 cases. Six patients improved and 1 patient died after thrombectomy. The average NIHSS score of the 6 cases was 3.67 at discharge. The average modified Rankin Scale score was 1 at the 3-month follow-up. Subarachnoid hemorrhage after thrombectomy occurred in 1 case and that patient died 3 days postoperatively.CONCLUSIONSThis study shows that mechanical thrombectomy using a Solitaire stent retriever has a high recanalization rate and excellent clinical prognosis in pediatric AIS. The safety of mechanical thrombectomy in pediatric AIS requires more clinical trials for confirmation.


Author(s):  
Simone Ghiselli ◽  
Cristina Carro ◽  
Nicola Uricchio ◽  
Giuseppe Annoni ◽  
Stefano M Marianeschi

Abstract OBJECTIVES Chronic pulmonary valve (PV) regurgitation is a common late sequela after repair of congenital heart diseases like tetralogy of Fallot or pulmonary stenosis, leading to right ventricular dilatation and failure and increased late morbidity and mortality. Timely reoperation may lead to a complete right ventricular recovery. An injectable PV allows pulmonary valve replacement, with or without cardiopulmonary bypass, under direct observation, thereby minimizing the impact of surgery on cardiac function. The aim of this study was to evaluate the feasibility and mid- to long-term clinical outcomes with this device. METHODS From April 2007 to October 2019, a total of 85 symptomatic patients with severe pulmonary regurgitation or pulmonary stenosis underwent pulmonary valve replacement with an injectable stented pulmonary prosthesis. Data were collected from the international proctoring registry. Mean patient age was 26.7 years. The underlying diagnosis was repaired tetralogy of Fallot in 69.4% patients; moderate or severe pulmonary regurgitation was present in 72.9%. All patients had echocardiographic scans before the operation and during the follow-up period. A total of 54.1% patients also had preoperative/postoperative cardiac magnetic resonance imaging (MRI) or catheterization; 25.9% had off-pump implants. In 53% patients, pulmonary valve replacement was associated with the repair of other cardiac defects. RESULTS Minor postoperative complications were observed in 10.8% patients. The overall mortality rate was 2.3%; mortality after valve replacement was linked to a severe cardiac insufficiency and it was not related to a prosthesis failure; 1 prosthesis was explanted from 1 patient because of endocarditis, and 6% of patients developed PV stenosis; minor complications occurred in 4.8%. The mean follow-up period was 4.8 years (2 months–12.7 years); 42% of the patients were followed for more than 5 years. Follow-up echocardiography and cardiac MRI showed a significant reduction in RV size and low gradients across the PV. CONCLUSIONS An injectable PV may be implanted without cardiopulmonary bypass and in a hybrid operating theatre with minimal surgical impact. The bioprosthesis, available up to large sizes, has a low profile, laminar flow and no risk of coronary artery compression. Incidence of endocarditis is rare. The lack of a suture ring permits the implant of a relatively larger prosthesis, thereby avoiding a right ventricular outflow tract obstruction. This device permits future percutaneous valve-in-valve procedures, if needed. Results concerning durability are encouraging, and mid- to long-term haemodynamic performance is excellent.


2019 ◽  
Vol 12 ◽  
pp. 263177451986778 ◽  
Author(s):  
Tomazo Franzini ◽  
Vitor M.T. Sagae ◽  
Hugo G. Guedes ◽  
Paulo Sakai ◽  
Daniel R. Waisberg ◽  
...  

Background and aims: Post liver transplant biliary anastomotic strictures have traditionally been treated with balloon dilation and multiple plastic stents. Fully covered self-expandable metallic stents may be used as an initial alternative or after multiple plastic stents failure. Refractory strictures can occur in 10–22% and require revisional surgery. Alternatively, cholangioscopy allows direct visualization and therapeutic approaches. We aimed to assess the feasibility, safety, and efficacy of balloon dilation combined with cholangioscopy-guided steroid injection for the treatment of refractory anastomotic biliary strictures. Methods: Three post-orthotopic liver transplant patients who failed standard treatment of their biliary anastomotic strictures underwent endoscopic retrograde cholangiopancreatography with balloon dilation followed by cholangioscopy-guided steroid injection at a tertiary care center. Patients had follow-up with images and laboratorial tests to evaluate for residual stricture. Results: Technical success of balloon dilation + cholangioscopy-guided steroid injection was achieved in all patients. Cholangioscopy permitted accurate evaluation of bile ducts and precise localization for steroid injection. No adverse events occurred. Mean follow-up was 26 months. Two patients are stent free and remain well in follow-up, with no signs of biliary obstruction. No further therapeutic endoscopic procedures or revisional surgery were required. One patient did not respond to balloon dilation + cholangioscopy-guided steroid injection after 11 months of follow-up and required repeat balloon dilation of new strictures above the anastomosis. Conclusion: Cholangioscopy-guided steroid injection combined with balloon dilation in the treatment of refractory post liver transplant strictures is feasible and safe. This method may be used as a rescue alternative before surgical approach. Randomized controlled trials comparing balloon dilation + cholangioscopy-guided steroid injection to fully covered self-expandable metallic stents are needed to determine the role of this treatment for anastomotic biliary strictures.


Angiology ◽  
1981 ◽  
Vol 32 (5) ◽  
pp. 311-320 ◽  
Author(s):  
Francisco Hernandez ◽  
Agustin W. Castellanos

Sign in / Sign up

Export Citation Format

Share Document