scholarly journals Silicon strip detectors for two-dimensional soft X-ray imaging at normal incidence

Author(s):  
P. Rato Mendes ◽  
M.C. Abreu ◽  
G. Baldazzi ◽  
D. Bollini ◽  
A.E. Cabal Rodriguez ◽  
...  
2008 ◽  
Author(s):  
L. Bolaños ◽  
A. E. Cabal ◽  
P. Grybos ◽  
P. Maj ◽  
A. Marzari ◽  
...  

2005 ◽  
Vol 32 (12) ◽  
pp. 3755-3766 ◽  
Author(s):  
C. Avila ◽  
J. Lopez ◽  
J. C. Sanabria ◽  
G. Baldazzi ◽  
D. Bollini ◽  
...  

1990 ◽  
Vol 61 (10) ◽  
pp. 2756-2758 ◽  
Author(s):  
R. Kaita ◽  
S. von Goeler ◽  
S. Sesnic ◽  
S. Bernabei ◽  
E. Fredrickson ◽  
...  

2021 ◽  
Vol 16 (12) ◽  
pp. C12014
Author(s):  
M. Zoladz ◽  
P. Grybos ◽  
R. Szczygiel

Abstract X-ray imaging of moving objects using line detectors remains the most popular method of object content and structure examination with a typical resolution limited to 0.4–1 mm. Higher resolutions are difficult to obtain as, for the detector in the form of a single pixel row, the narrower the detector is, the lower the image Signal to Noise Ratio (SNR). This is because, for smaller pixel sizes, fewer photons hit the pixel in each time unit for a given radiation intensity. To overcome the trade-off between the SNR and spatial resolution, a two-dimensional sensor, namely a pixel matrix can be used. Imaging of moving objects with a pixel matrix requires time-domain integration (TDI). Straightforward TDI implementation is based on the proper accumulation of images acquired during consecutive phases of an object’s movement. Unfortunately, this method is much more demanding regarding data transfer and processing. Data from the whole pixel matrix instead of a single pixel row must be transferred out of the chip and then processed. The alternative approach is on-chip TDI implementation. It takes advantage of photons acquired by multiple rows (a higher SNR), but generates similar data amount as a single pixel row and does not require data processing out of the chip. In this paper, on-chip TDI is described and verified by using a single photon counting two-dimensional (a matrix of 128 × 192 pixels) CdTe hybrid X-ray detector with the 100 µm × 100 µm pixel size with up to four energy thresholds per pixel. Spatial resolution verification is combined with the Material Discrimination X-ray (MDX) imaging method.


Micron ◽  
2010 ◽  
Vol 41 (7) ◽  
pp. 722-728 ◽  
Author(s):  
I.A. Artyukov ◽  
R.M. Feschenko ◽  
A.V. Vinogradov ◽  
Ye.A. Bugayev ◽  
O.Y. Devizenko ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document