High energy X-ray photon counting imaging using linear accelerator and silicon strip detectors

Author(s):  
Y. Tian ◽  
K. Shimazoe ◽  
X. Yan ◽  
O. Ueda ◽  
T. Ishikura ◽  
...  
2021 ◽  
pp. 1-13
Author(s):  
Muhammad U. Ghani ◽  
Farid H. Omoumi ◽  
Xizeng Wu ◽  
Laurie L. Fajardo ◽  
Bin Zheng ◽  
...  

PURPOSE: To compare imaging performance of a cadmium telluride (CdTe) based photon counting detector (PCD) with a CMOS based energy integrating detector (EID) for potential phase sensitive imaging of breast cancer. METHODS: A high energy inline phase sensitive imaging prototype consisting of a microfocus X-ray source with geometric magnification of 2 was employed. The pixel pitch of the PCD was 55μm, while 50μm for EID. The spatial resolution was quantitatively and qualitatively assessed through modulation transfer function (MTF) and bar pattern images. The edge enhancement visibility was assessed by measuring edge enhancement index (EEI) using the acrylic edge acquired images. A contrast detail (CD) phantom was utilized to compare detectability of simulated tumors, while an American College of Radiology (ACR) accredited phantom for mammography was used to compare detection of simulated calcification clusters. A custom-built phantom was employed to compare detection of fibrous structures. The PCD images were acquired at equal, and 30% less mean glandular dose (MGD) levels as of EID images. Observer studies along with contrast to noise ratio (CNR) and signal to noise ratio (SNR) analyses were performed for comparison of two detection systems. RESULTS: MTF curves and bar pattern images revealed an improvement of about 40% in the cutoff resolution with the PCD. The excellent spatial resolution offered by PCD system complemented superior detection of the diffraction fringes at boundaries of the acrylic edge and resulted in an EEI value of 3.64 as compared to 1.44 produced with EID image. At MGD levels (standard dose), observer studies along with CNR and SNR analyses revealed a substantial improvement of PCD acquired images in detection of simulated tumors, calcification clusters, and fibrous structures. At 30% less MGD, PCD images preserved image quality to yield equivalent (slightly better) detection as compared to the standard dose EID images. CONCLUSION: CdTe-based PCDs are technically feasible to image breast abnormalities (low/high contrast structures) at low radiation dose levels using the high energy inline phase sensitive imaging technique.


2008 ◽  
Author(s):  
L. Bolaños ◽  
A. E. Cabal ◽  
P. Grybos ◽  
P. Maj ◽  
A. Marzari ◽  
...  

2016 ◽  
Vol 47 (2) ◽  
pp. 279 ◽  
Author(s):  
P. Wiącek ◽  
W. Dąbrowski

2004 ◽  
Vol 443-444 ◽  
pp. 175-180 ◽  
Author(s):  
A. Zięba ◽  
W. Dąbrowski ◽  
P. Gryboś ◽  
W. Pawroźnik ◽  
J.R. Słowik ◽  
...  

Silicon strip detectors represent a new class of one-dimensional position-sensitive single photon counting devices. They allow a reduction of measurement time at the powder diffractometers by a factor up to 100 compared to instruments with a single counter, while maintaining comparable count statistics. Present work describes a 128-channel detector working with a standard diffractometer. The detector is 12.8 mm long and covers the angular range of 3.2 deg. We discuss the diffraction geometry in real and reciprocal space, the FWHM of diffraction peaks, and the background level. Measurements were made on standard samples and on complex samples of industrial importance (e. g., portland clinker). Applications of the detector to diffraction measurements of single crystals and thin films are discussed briefly.