Application of Gas Chromatography/Mass Spectrometry Instrument Techniques to Forensic Urine Drug Testing

1990 ◽  
Vol 10 (2) ◽  
pp. 271-288 ◽  
Author(s):  
Lehrer Michael
1994 ◽  
Vol 40 (5) ◽  
pp. 729-733 ◽  
Author(s):  
M A Huestis ◽  
J M Mitchell ◽  
E J Cone

Abstract Proposed changes to the Health and Human Services Guidelines for forensic urine drug testing will lower the required cannabinoid immunoassay cutoff concentration from 100 to 50 micrograms/L. We investigated the effect of this change on the sensitivity, specificity, and efficiency of eight cannabinoid immunoassays: Syva Emit d.a.u. 100; Syva Emit II 100; Syva Emit d.a.u. 50; Syva Emit II 50; Roche Abuscreen Online; Roche Abuscreen radioimmunoassay; Diagnostic Reagents; and Abbott ADx. All specimens also were assayed by gas chromatography/mass spectrometry. Lowering the cutoff concentration from 100 to 50 micrograms/L increased efficiencies and sensitivities for all immunoassays, with minor decreases in specificity (1.0-2.6%). There was a 23.2-53.6% increase in the number of true-positive specimens identified. Thus, lowering the cannabinoid immunoassay cutoff concentration from 100 to 50 micrograms/L resulted in detection of a substantial number of additional true-positive specimens, with an accompanying small increase in unconfirmed positive results.


1994 ◽  
Vol 40 (3) ◽  
pp. 373-380 ◽  
Author(s):  
R L Fitzgerald ◽  
D A Rexin ◽  
D A Herold

Abstract We tested 231 urine samples by six immunoassay methods--EMIT d.a.u., EMIT II, Roche Abuscreen Online, Abbott TDx, Diagnostic Products Corp. (DPC) double-antibody radioimmunoassay (RIA), and Biosite Triage--and by negative chemical ionization gas chromatography/mass spectrometry to determine how the immunoassays performed on samples selected for suspected benzodiazepine use (n = 100) and in random urine drug screening (n = 131). In general, all of the assays were successful in detecting oxazepam and related metabolites, even at concentrations below the stated cutoffs. However, the negative predictive value of benzodiazepine immunoassays for samples selected for suspected benzodiazepine use ranged from 86% to 96%. A primary difference between the test kits was the ability of DPC RIA and Triage to detect lorazepam when other assays did not. Contrary to previous reports, pretreatment of specimens with glucuronidase was not necessary to detect oxazepam-related metabolites with these immunoassays.


Sign in / Sign up

Export Citation Format

Share Document