scholarly journals Results of U.S. phase I and II clinical trials of transcatheter closure of patent ductus arteriosus in adult patients using the amplatzerfi duct occlud

2003 ◽  
Vol 41 (6) ◽  
pp. 75
Author(s):  
Tom Hong ◽  
Ziyad M. Hijazi ◽  
William E. Hellenbrand ◽  
John P. Cheatham ◽  
Zahid Amin ◽  
...  
2020 ◽  
Vol 17 (2) ◽  
pp. 43-46
Author(s):  
Chandra Mani Adhikari ◽  
Amrit Bogati ◽  
Kiran Prasad Acharya ◽  
Manish Shrestha ◽  
Urmila Shakya ◽  
...  

Background and Aims: Transcatheter closure of patent ductus arteriosus (PDA) using either coils or device is a well-established procedure. PDA is one of the common congenital heart diseases and it is not uncommon for it to be diagnosed in adulthood. However, only few studies are conducted in our part of the world regarding the safety and procedural success of device closure of PDA in adults. We aim to assess safety and procedural success of transcatheter closure of PDA in adults at Shahid Gangalal National Heart Centre, Kathmandu, Nepal. Methods: It was a single center, retrospective study. Cardiac catheterization laboratory records of all consecutive adult patients (age ≥ 18 years) who underwent PDA device closure between March 2007 to March 2020 were reviewed. Patients age, gender, device size and device type along with procedural success of the procedure were reviewed. Any complication recorded was reviewed. Results: During the study period 118 adult patients were attempted for transcatheter closure of PDA. In three cases transcatheter closure was not attempted. In one patients attempt was made to close the duct with cook coil which embolized to pulmonary artery. PDA was successfully closed in 114 patients. Among the 114 patients, 87 were females and 27 were male. Age ranged from 18 to 69 years with mean age was 29.5 years. PDA size ranged from 3mm to 18mm with the mean of 6.9mm. In two patients, residual PDA after surgical closure were closed. Amplatzer duct occluder was the most commonly used device used in 89 (78%) patients followed by Memopart PDA device in 11 (9.6%) patients, Amplatzer Muscular VSD occluder in four patients. Device size of “8x10” in 32 patients and “10x12” device in 29 patients, were the most commonly used device size. Conclusion: Transcatheter closure of PDA in adults can safely be done with high success rate.


2016 ◽  
Vol 12 (3) ◽  
pp. 289-293 ◽  
Author(s):  
Xinghua Gu ◽  
Qiuwang Zhang ◽  
Hourong Sun ◽  
Jianchun Fei ◽  
Xiquan Zhang ◽  
...  

2021 ◽  
pp. 1-4
Author(s):  
Zahra Khajali ◽  
Ata Firouzi ◽  
Homa Ghaderian ◽  
Maryam Aliramezany

Abstract Ductus arteriosus is a physiological structure if not closed after birth, may lead to many complications. Today, trans-catheter closure of patent ductus arteriosus with Occluder devices is the preferred method. Surgical ligation is used only in certain cases such as large symptomatic patent ductus arteriosus in very small infants and premature babies; unfavourable structure of the duct or economic considerations. In this article, we described haemodynamic and morphological characteristics of five patients with large patent ductus arteriosus which were occluded with Amplatzer device. From 23 January, 2010 to 31 July, 2018, five patients referred to our clinic with large patent ductus arteriosus and pulmonary arterial hypertension for further evaluation. After assessing them with various diagnostic methods, we decided to close defect with ventricular septal defect Occluder device. Patients aged 21–44 years and one of them was male. Ductus closure was successfully done with ventricular septal defect Occluder device. Closure was successful for all of them but in one case, whose device was embolized to pulmonary artery after 24 hr and he underwent surgery. Trans-catheter closure of large patent ductus arteriosus in adult patients with pulmonary hypertension is feasible. Despite the fact that complications may occur even with the most experienced hands, the ‘double disk’ Amplatzer ventricular septal defect muscular Occluder could be advantageous in this setting.


2020 ◽  
Vol 72 (1) ◽  
Author(s):  
Sanjeev H. Naganur ◽  
C. R. Pruthvi ◽  
Dinakar Bootla ◽  
Krishna Prasad ◽  
V. Krishna Santosh ◽  
...  

2021 ◽  
pp. 1-3
Author(s):  
Yoko Kawai ◽  
Takeshi Nakamura ◽  
Satoaki Matoba

Abstract In older adults with patent ductus arteriosus, CT is widely used for duct visualisation because angiography images can be inadequate for evaluation. We report the case of a 73-year-old woman with a highly calcified patent ductus arteriosus whose CT images were insufficient for accurate measurement. Intravascular ultrasonography is useful for sizing of and guiding device closure of the duct.


2021 ◽  
Vol 13 (4) ◽  
pp. 282-283
Author(s):  
Chloé Wanert ◽  
Marien Lenoir ◽  
Damien Bonnet ◽  
Mathilde Meot ◽  
Virginie Fouilloux ◽  
...  

2005 ◽  
Vol 130 (4) ◽  
pp. 1203-1204 ◽  
Author(s):  
Naritatsu Saito ◽  
Takeshi Kimura ◽  
Masanao Toma ◽  
Kazunari Sasaki ◽  
Toru Kita ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document