Transcatheter closure of calcified patent ductus arteriosus in older adult patients: Immediate and 12-month follow-up results

2016 ◽  
Vol 12 (3) ◽  
pp. 289-293 ◽  
Author(s):  
Xinghua Gu ◽  
Qiuwang Zhang ◽  
Hourong Sun ◽  
Jianchun Fei ◽  
Xiquan Zhang ◽  
...  
2021 ◽  
pp. 1-3
Author(s):  
Yoko Kawai ◽  
Takeshi Nakamura ◽  
Satoaki Matoba

Abstract In older adults with patent ductus arteriosus, CT is widely used for duct visualisation because angiography images can be inadequate for evaluation. We report the case of a 73-year-old woman with a highly calcified patent ductus arteriosus whose CT images were insufficient for accurate measurement. Intravascular ultrasonography is useful for sizing of and guiding device closure of the duct.


2020 ◽  
Vol 17 (2) ◽  
pp. 43-46
Author(s):  
Chandra Mani Adhikari ◽  
Amrit Bogati ◽  
Kiran Prasad Acharya ◽  
Manish Shrestha ◽  
Urmila Shakya ◽  
...  

Background and Aims: Transcatheter closure of patent ductus arteriosus (PDA) using either coils or device is a well-established procedure. PDA is one of the common congenital heart diseases and it is not uncommon for it to be diagnosed in adulthood. However, only few studies are conducted in our part of the world regarding the safety and procedural success of device closure of PDA in adults. We aim to assess safety and procedural success of transcatheter closure of PDA in adults at Shahid Gangalal National Heart Centre, Kathmandu, Nepal. Methods: It was a single center, retrospective study. Cardiac catheterization laboratory records of all consecutive adult patients (age ≥ 18 years) who underwent PDA device closure between March 2007 to March 2020 were reviewed. Patients age, gender, device size and device type along with procedural success of the procedure were reviewed. Any complication recorded was reviewed. Results: During the study period 118 adult patients were attempted for transcatheter closure of PDA. In three cases transcatheter closure was not attempted. In one patients attempt was made to close the duct with cook coil which embolized to pulmonary artery. PDA was successfully closed in 114 patients. Among the 114 patients, 87 were females and 27 were male. Age ranged from 18 to 69 years with mean age was 29.5 years. PDA size ranged from 3mm to 18mm with the mean of 6.9mm. In two patients, residual PDA after surgical closure were closed. Amplatzer duct occluder was the most commonly used device used in 89 (78%) patients followed by Memopart PDA device in 11 (9.6%) patients, Amplatzer Muscular VSD occluder in four patients. Device size of “8x10” in 32 patients and “10x12” device in 29 patients, were the most commonly used device size. Conclusion: Transcatheter closure of PDA in adults can safely be done with high success rate.


2012 ◽  
Vol 8 (2) ◽  
pp. 159-166 ◽  
Author(s):  
Fadli Demir ◽  
Ahmet Celebi ◽  
Turkay Saritas ◽  
Abdullah Erdem ◽  
Halil Demir ◽  
...  

Author(s):  
Achyut Sarkar ◽  
Neha Rani ◽  
Prashant Kumar ◽  
Shyam Sundar Chaudhary ◽  
Suman Chatterjee

Background: Patent Ductus Arteriosus (PDA) is a common congenital disorder. As an isolated lesion, PDA constitutes 6 to 11% of all congenital heart disease. PDA needs closure to eliminate pulmonary over circulation leading to volume overload of left ventricle, pulmonary vascular obstructed disease.Methods: This retrospective study was carried out in pediatric cardiology unit of Institute of Postgraduate Medical Education and Research, Kolkata from September 2005 to August 2016, which included 503 patients.Results: Device closure was attempted in 492 patient’s Procedural success was achieved in 85% cases on table, in who check aortogram revealed complete closure of PDA. In 15% cases, residual shunt was present. In 12% of cases, residual shunt disappeared during follow-up echocardiogram over 6-month follow-up. In 3% cases, small shunt remained at 6-month and 1-year follow up.Conclusion: Transcatheter closure of PDA by duct occluder is safe and effective with good mid-term outcome. The optimum assessment of ductul size and anatomy is crucial for optimum device size, which prevents residual shunt, device embolization and protrusion.


2020 ◽  
Vol 2020 ◽  
pp. 1-8 ◽  
Author(s):  
Michal Galeczka ◽  
Malgorzata Szkutnik ◽  
Jacek Bialkowski ◽  
Sebastian Smerdzinski ◽  
Mateusz Knop ◽  
...  

Objectives. Patent ductus arteriosus (PDA) in elderly patients is an uncommon anomaly, and the duct itself is often calcified and fragile; therefore, transcatheter closure is more difficult. The aim is to analyse periprocedural and one-year follow-up results of transcatheter closure of PDA in such patients. Methods and results. Retrospective analysis of 33 elective patients aged ≥55 years (median 63; 56–85; 29 women), in whom PDA was closed percutaneously between 2002 and 2018 in two tertiary centres. All but three patients were symptomatic, with most in NYHA II (n = 14) and III (n = 11) class; pulmonary hypertension (n = 22), arterial hypertension (n = 22), duct calcifications (n = 17), atrial fibrillation (n = 15), significant mitral regurgitation (n = 5), and decompensated renal failure (n = 2) were observed. Different devices were applied depending on PDA morphology; nitinol wire mesh occluders with symmetrical articulating discs have been the most used in recent years (n = 11). Follow-up was conducted at an outpatient clinic (28/33 patients). The procedure was successful in all patients. There was one embolisation, followed by implantation of a larger device. No major complications were noted. A small residual shunt was present in echocardiography in one patient after one year. NYHA class improved in all but two patients (with multiple comorbidities). Conclusions. Transcatheter PDA closure in elderly patients is safe and efficient with a high complete closure rate and few complications. Amplatzer duct occluder type II is an attractive device in such patients.


Heart Views ◽  
2019 ◽  
Vol 20 (4) ◽  
pp. 139
Author(s):  
Wail Alkashkari ◽  
Saad Albugami ◽  
Jamilah Alrahimi ◽  
Mohammed Althobaiti ◽  
Abdulhalim Kinsara ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document