Self-Tuning Load-Frequency Control of the Hungarian Power System

1981 ◽  
Vol 14 (2) ◽  
pp. 3095-3101
Author(s):  
I. Vajk ◽  
M. Vajta ◽  
L. Keviczky ◽  
R. Haber ◽  
J. Hetthéssy ◽  
...  
2010 ◽  
Vol 2 (2) ◽  
pp. 285-293 ◽  
Author(s):  
M. R. I. Sheikh ◽  
R. Takahashi ◽  
J. Tamura

Since superconducting magnetic energy storage (SMES) unit with a self-commutated converter is capable of controlling both the active and reactive powers simultaneously and quickly, increasing attention has been focused recently on power system stabilization by SMES control. This study presents the effects of novel control strategies of self-tuned fuzzy proportional integral (FPI) controller and fuzzy frequency (FF) controller associated with the automatic generation control (AGC) including SMES unit. The effects of the self-tuning configuration with FPI controller in AGC is also compared with that of FF controlled AGC on SMES control. The simulation results show that both self tuning control schemes of AGC are very effective in damping out of the oscillations caused by load disturbances and it is also seen that the FF controlled AGC with SMES perform better primary frequency control compared to FPI controlled AGC with SMES. Keywords: Load frequency control; Single area power system; FPI controller; FF controller; SMES unit. © 2010 JSR Publications. ISSN: 2070-0237 (Print); 2070-0245 (Online). All rights reserved.    DOI: 10.3329/jsr.v2i2.3063               J. Sci. Res. 2 (2), 285-293 (2010) 


2012 ◽  
Author(s):  
M.R.I. Sheikh ◽  
M.S Anower ◽  
M. G. Rabbani

Since a Superconducting Magnetic Energy Storage (SMES) unit with a self–commutated converter is capable of controlling both the active and reactive powers simultaneously and quickly, increasing attention has been focused recently on power system stabilization by SMES control. This paper presents a novel control method of SMES with a self-tuned Fuzzy Proportional Integral (FPI) controller associated with the Automatic Generation Control (AGC) for improving Load Frequency Control (LFC) in a single area power system. Boiler dynamics and nonlinearities such as governor dead band (DB) and generator rate constraints (GRC) are considered in the developed comprehensive mathematical model of a single area isolated power system. The effects of the self–tuning configuration of FPI controller in AGC on SMES control is compared with that of fixed gain PI controlled AGC. It is seen that with addition of FPI controller, SMES can perform a more effective primary frequency control for single area power system. Key words: Load frequency control; single area power system; automatic generation control; superconducting magnetic energy storage unit; fuzzy proportional integral controller


2020 ◽  
Vol 53 (2) ◽  
pp. 12536-12541
Author(s):  
Li Jin ◽  
Xingchen Shang-Guan ◽  
Yong He ◽  
Chuan-Ke Zhang ◽  
Lin Jiang ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1581
Author(s):  
Deepak Kumar Gupta ◽  
Amitkumar V. Jha ◽  
Bhargav Appasani ◽  
Avireni Srinivasulu ◽  
Nicu Bizon ◽  
...  

The automatic load frequency control for multi-area power systems has been a challenging task for power system engineers. The complexity of this task further increases with the incorporation of multiple sources of power generation. For multi-source power system, this paper presents a new heuristic-based hybrid optimization technique to achieve the objective of automatic load frequency control. In particular, the proposed optimization technique regulates the frequency deviation and the tie-line power in multi-source power system. The proposed optimization technique uses the main features of three different optimization techniques, namely, the Firefly Algorithm (FA), the Particle Swarm Optimization (PSO), and the Gravitational Search Algorithm (GSA). The proposed algorithm was used to tune the parameters of a Proportional Integral Derivative (PID) controller to achieve the automatic load frequency control of the multi-source power system. The integral time absolute error was used as the objective function. Moreover, the controller was also tuned to ensure that the tie-line power and the frequency of the multi-source power system were within the acceptable limits. A two-area power system was designed using MATLAB-Simulink tool, consisting of three types of power sources, viz., thermal power plant, hydro power plant, and gas-turbine power plant. The overall efficacy of the proposed algorithm was tested for two different case studies. In the first case study, both the areas were subjected to a load increment of 0.01 p.u. In the second case, the two areas were subjected to different load increments of 0.03 p.u and 0.02 p.u, respectively. Furthermore, the settling time and the peak overshoot were considered to measure the effect on the frequency deviation and on the tie-line response. For the first case study, the settling times for the frequency deviation in area-1, the frequency deviation in area-2, and the tie-line power flow were 8.5 s, 5.5 s, and 3.0 s, respectively. In comparison, these values were 8.7 s, 6.1 s, and 5.5 s, using PSO; 8.7 s, 7.2 s, and 6.5 s, using FA; and 9.0 s, 8.0 s, and 11.0 s using GSA. Similarly, for case study II, these values were: 5.5 s, 5.6 s, and 5.1 s, using the proposed algorithm; 6.2 s, 6.3 s, and 5.3 s, using PSO; 7.0 s, 6.5 s, and 10.0 s, using FA; and 8.5 s, 7.5 s, and 12.0 s, using GSA. Thus, the proposed algorithm performed better than the other techniques.