Left Atrial Posterior Wall and Pulmonary Vein Refractory Periods Are Associated With Atrial Fibrillation Inducibility in a Swine Model

2006 ◽  
Vol 59 (7) ◽  
pp. 653-661 ◽  
Author(s):  
Ignacio Fernández-Lozano ◽  
Jorge Toquero-Ramos ◽  
Cristina Escudero-Vela ◽  
Evaristo Castedo-Mejuto ◽  
Juan M. Escudier-Villa ◽  
...  
Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S127-S128
Author(s):  
Leonid Garber ◽  
Lior Jankelson ◽  
Eric H. Shulman ◽  
Roi Bar-Cohen ◽  
Connor Peterson ◽  
...  

Heart Rhythm ◽  
2016 ◽  
Vol 13 (1) ◽  
pp. 132-140 ◽  
Author(s):  
Rong Bai ◽  
Luigi Di Biase ◽  
Prasant Mohanty ◽  
Chintan Trivedi ◽  
Antonio Dello Russo ◽  
...  

2009 ◽  
Vol 2 (1) ◽  
pp. 35-40 ◽  
Author(s):  
David Tamborero ◽  
Lluís Mont ◽  
Antonio Berruezo ◽  
Maria Matiello ◽  
Begoña Benito ◽  
...  

2008 ◽  
Vol 105 (1) ◽  
pp. 293-298 ◽  
Author(s):  
Lei Liang ◽  
Qin Pan ◽  
Yi Liu ◽  
Huaizhi Chen ◽  
Jun Li ◽  
...  

Isolation of the pulmonary vein antrum can terminate atrial fibrillation, but the rationale has not been elucidated. In the present study, we show that sheep atrial effective refractory period (ERP) was heterogeneously shortened by acetylcholine administration. After perfusion with 15 μM acetylcholine, the shortest ERP occurred in the pulmonary vein antrum, which was recorded with the standard intracellular microelectrode technique (the ERP results in the pulmonary vein antrum, left atrial posterior wall, roof, free wall and appendage, and right atrial free wall were 52.0 ± 1.6, 75.1 ± 2.0, 77.2 ± 1.7, 85.6 ± 1.7, 64.3 ± 2.1, and 90.5 ± 1.3 ms, respectively; P < 0.05). Immunofluorescent staining revealed that muscarinic type 2 receptors (M2R) were also distributed heterogeneously in the atrial myocardium, with the highest density in the antrum (the relative fluorescent intensity results of the M2R in the pulmonary vein antrum, left atrial posterior wall, roof, free wall and appendage, and right atrial free wall were 62.64 ± 2.56, 53.12 ± 2.76, 51.83 ± 2.45, 47.90 ± 2.33, 55.27 ± 2.08, and 45.53 ± 2.02, respectively; P < 0.05), which was in accordance with the heterogeneity of ERP distribution. Thus the pulmonary vein antrum is a unique electrophysiological region with high sensitivity to acetylcholine, and its intensive response to acetylcholine is most likely associated with the dense M2R distribution of this region. Such an acetylcholine-induced ERP heterogeneity is possibly a substrate for atrial fibrillation and hence one of the potential electrophysiological bases for the isolation therapy.


Sign in / Sign up

Export Citation Format

Share Document