Intubation Efficiency and Perceived Ease of Use of Video Laryngoscopy vs Direct Laryngoscopy While Wearing HazMat PPE: A Preliminary High-fidelity Mannequin Study

2015 ◽  
Vol 30 (3) ◽  
pp. 259-263 ◽  
Author(s):  
Sara J. Aberle ◽  
Benjamin J. Sandefur ◽  
Kharmene L. Sunga ◽  
Ronna L. Campbell ◽  
Christine M. Lohse ◽  
...  

AbstractIntroductionManagement of contaminated patients in the decontamination corridor requires the use of hazardous material (HazMat) personal protective equipment (PPE). Previous studies have demonstrated that HazMat PPE may increase the difficulty of airway management. This study compared the efficiency of video laryngoscopy (VL) with traditional direct laryngoscopy (DL) during endotracheal intubation (ETI) while wearing HazMat PPE.MethodsPost-graduate year (PGY) 1-3 Emergency Medicine residents were randomized to VL or DL while wearing encapsulating PPE. Video laryngoscopy was performed using the GlideScope Cobalt AVL video laryngoscope. The primary outcome measure was time to successful ETI in a high-fidelity simulation mannequin. Three time points were utilized in the analysis: Time 0 (blade at lips), Time 1 (blade removed from lips after endotracheal tube placement), and Time 2 (bag valve mask [BVM] attached to endotracheal tube). Secondary outcome measures were perceived ease of use and feasibility of VL and DL ETI modalities.ResultsTwenty-one of 23 (91.3%) eligible residents participated. Mean time to ETI was 10.0 seconds (SD=5.3 seconds) in the DL group and 7.8 seconds (SD=3.0 seconds) in the VL group (P=.081). Mean times from blade insertion until BVM attachment were 17.4 seconds (SD=6.0 seconds) and 15.6 seconds (SD=4.6 seconds), respectively (P=.30). There were no unsuccessful intubation attempts. Seventeen out of 20 participants (85.0%) perceived VL to be easier to use when performing ETI in PPE. Twelve out of 20 participants (60%) perceived DL to be more feasible in an actual HazMat scenario.ConclusionThe time to successful ETI was not significantly different between VL and DL. Video laryngoscopy had a greater perceived ease of use, but DL was perceived to be more feasible for use in actual HazMat situations. These findings suggest that both DL and VL are reasonable modalities for use in HazMat situations, and the choice of modality could be based on the clinical situation and provider experience.AberleSJ, SandefurBJ, SungaKL, CampbellRL, LohseCM, Alecastro PulsH, LaudonS, SztajnkrycerMD. Intubation efficiency and perceived ease of use of video laryngoscopy vs direct laryngoscopy while wearing HazMat PPE: a preliminary high-fidelity mannequin study. Prehosp Disaster Med. 2015;30(3):1–5.

Resuscitation ◽  
2010 ◽  
Vol 81 (6) ◽  
pp. 737-741 ◽  
Author(s):  
G.M. Schmölzer ◽  
S.B. Hooper ◽  
K.J. Crossley ◽  
B.J. Allison ◽  
C.J. Morley ◽  
...  

2021 ◽  
pp. 8-13
Author(s):  
Pankaj Kumar Singh ◽  
Budhaditya Sanyal ◽  
Mohit Bhatnagar ◽  
Mandeep Joshi ◽  
Shreya Verma

Aims and objectives: This study aims to assess the diagnostic accuracy and timeliness of ultrasonography by static method only for identication of Endotracheal tube (ET Tube) placement in the trachea in emergency settings vs existing clinical methods. Material and Methods: This prospective study was carried out in the emergency room from October 2018 till the end of March 2019. The ultrasonography was performed in 120 emergency patients only after the intubation had been completed ie, static phase. A linear probe was used over the neck to identify the predened signs of ET intubation. Residents who perform ultrasound examination ll a form after assessment of each patient. Results: It was found that Tracheal Intubation-USG Sensitivity was 99.1, Specicity was 91.7, Positive Predictive Value: 99.1, Negative Predictive Value was 91.7 and Accuracy was 98.3%. Ultrasonography can be used as an adjunct tool to verify the ETTposition by Emergency Physicians which can be performed easily after a brieng or short-course training.Conclusion:This study demonstrates that US imaging has a high diagnostic accuracy to immediately conrm proper ETT placement post-intubation in an emergency setup. Therefore, it seems that ultrasonography using a static technique only is a proper screening tool in determining endotracheal tube placement.


2018 ◽  
Vol 51 (1) ◽  
pp. 20-25 ◽  
Author(s):  
Mariana Chiaradia Dominguez ◽  
Beatriz Regina Alvares

Abstract Objective: To analyze the radiological aspects of pulmonary atelectasis in newborns on mechanical ventilation and treated in an intensive care unit, associating the characteristics of atelectasis with the positioning of the head and endotracheal tube seen on the chest X-ray, as well as with the clinical variables. Materials and Methods: This was a retrospective cross-sectional study of 60 newborns treated between 1985 and 2015. Data were collected from medical records and radiology reports. To identify associations between variables, we used Fisher's exact test. The level of significance was set at p < 0.05. Results: The clinical characteristics associated with improper positioning of the endotracheal tube were prematurity and a birth weight of less than 1000 g. Among the newborns evaluated, the most common comorbidity was hyaline membrane disease. Atelectasis was seen most frequently in the right upper lobe, although cases of total atelectasis were more common in the left lung. Malpositioning of the head showed a trend toward an association with atelectasis in the left upper lobe. Conclusion: Pulmonary atelectasis is a common complication in newborns on mechanical ventilation. Radiological evaluation of the endotracheal tube placement provides relevant information for the early correction of this condition.


1995 ◽  
Vol 20 (10) ◽  
pp. 939-940
Author(s):  
RONALD J. ROSENBERG ◽  
RICHARDO E. SANTIAG ◽  
RICHARD P. SPENCER

2017 ◽  
Vol 21 (5) ◽  
pp. 257-261 ◽  
Author(s):  
Vimal Koshy Thomas ◽  
Cherish Paul ◽  
Punchalil Chathappan Rajeev ◽  
Babu Urumese Palatty

2018 ◽  
Vol 36 (11) ◽  
pp. 1943-1946
Author(s):  
Erkman Sanri ◽  
Ebru Unal Akoglu ◽  
Sinan Karacabey ◽  
Ural Verimli ◽  
Haldun Akoglu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document