Conductometric determination of sulfur in beryllium oxide ceramics using induction heating and peroxide absorption

1968 ◽  
Vol 40 (1) ◽  
pp. 202-204 ◽  
Author(s):  
James F. Chapman ◽  
Malcolm. Thackray
1995 ◽  
Vol 31 (3) ◽  
pp. 2158-2161 ◽  
Author(s):  
Ghun-Deok Suh ◽  
Hong-Bae Lee ◽  
Song-Yop Hahn ◽  
Tae-Kyung Chung ◽  
Il-Han Park

Refractories ◽  
1969 ◽  
Vol 10 (5-6) ◽  
pp. 314-315
Author(s):  
Yu. A. Kocherzhinskii ◽  
E. A. Shishkin ◽  
L. M. Yupko

2006 ◽  
Vol 513 ◽  
pp. 61-68
Author(s):  
P. Kula ◽  
T. Liskiewicz ◽  
T. Pacyniak

The process of induction heating followed by forced cooling of large-scale castings is considered. The main goal of this study is to develop a reliable design methodology of surface heat treatment process to provide high quality of the treated component. It is assured by determination of the material constants and convection coefficient during heating and cooling experiments carried out on the specimens made of material adequate to the considered large-scale casting. The main part of the investigations was preceded by wide analyses of the mechanical and chemical properties of the tested specimens. The presented global design methodology of large-scale castings gives a possibility to predict the temperature distribution on the hardened surface during induction heating and forced cooling. This allows to select the most adequate parameters and apply them in a real specific process. The obtained results have been analyzed and discussed.


2019 ◽  
Vol 19 (1) ◽  
pp. 38-44
Author(s):  
Serdar Şahin ◽  
Eren Şahiner ◽  
Fatih Göksel ◽  
Niyazi Meriç

AbstractIntroduction:In this study, the differences between calculated and measured dose values were then analysed to assess the performance, in terms of accuracy, of the tested treatment planning system (TPS) algorithms applied to calculate electron beam dose targeted and non-targeted the breast region.Materials and methods:The beryllium oxide (BeO) dosimeters placed on the female RANDO phantom were irradiated 12 MeV electron energy with medical linear accelerator and repeatedly read in the Risø thermoluminescence (TL)/optically stimulated luminescence (OSL) system via OSL method at least three times.Results:For electron treatment, one made quantitative comparisons of the dose distributions calculated by TPSs with those from the measurements by OSL at various points in the RANDO phantom.The mean dose measured from the dosimeters placed on the female RANDO phantom target left breast region was 160 cGy and non-target right breast region was 1·2 cGy. Analysis of Generalised Gaussian Pencil Beam (GGPB) and Electron Monte Carlo (eMC) algorithms for determined region mean point dose values, respectively, 174 and 164 cGy. Two algorithms for non-targeted region calculated same point dose values of 0·2 cGy.Conclusions:The results of this study showed that BeO dosimeters can be used with OSL method in radiotherapy applications and it is a very important tool for the determination of targeted/non-targeted absorbed dose.


Sign in / Sign up

Export Citation Format

Share Document