A Simple Competitive Protein-Binding Experiment

1994 ◽  
Vol 71 (11) ◽  
pp. 994 ◽  
Author(s):  
Alexander J. Anderson
1970 ◽  
Vol 64 (4) ◽  
pp. 630-636 ◽  
Author(s):  
Stephen C. Thorson ◽  
Ronald Tsujikawa ◽  
James L. Brown ◽  
Robert T. Morrison ◽  
Hamish W. McIntosh

ABSTRACT Serum thyroxine concentrations were determined in 66 euthyroid, 30 hyperthyroid and 13 hypothyroid patients using both the established Murphy method and a simplified method of competitive protein binding analysis. A diagnosis compatibility of 96% was found with both methods indicating that the simplified method has comparable clinical application as an initial screen of thyroid status.


1970 ◽  
Vol 63 (2) ◽  
pp. 225-241 ◽  
Author(s):  
B. D. Reeves ◽  
M. L. A. de Souza ◽  
I. E. Thompson ◽  
E. Diczfalusy

ABSTRACT An improved method for the assay of plasma progesterone by competitive protein binding is described. The improvement is based upon rigorous control of the variables, the compensation for and standardisation of interfering factors inherent in the method and the use of a human corticosteroid binding globulin, that meets the requirements for sensitivity at levels of 1.0 ng of progesterone and below. The assessment of the reliability of the individual steps in the method as well as that of the complete method is presented. The sensitivity of the method is around 0.2 ng progesterone per ml plasma. Accuracy was measured by adding progesterone in amounts ranging from 0.0 to 1.0 ng to 1.0 ml plasma. There was a linear relationship between the progesterone added and recovered throughout the entire range of values, with a coefficient of correlation (r) of 0.94. Of 52 related steroids tested, none was found which would remain associated with progesterone following extraction and purification and which would also compete with progesterone for binding sites.


1970 ◽  
Vol 65 (1_Suppl) ◽  
pp. S61-S78 ◽  
Author(s):  
Billy D. Reeves ◽  
David W. Calhoun

ABSTRACT This communication is an attempt to delineate and define reliability criteria for saturation analysis of steroids by competitive protein binding assay. The discussion of these criteria evolved from three major considerations of assay method that help to place the ultimate criterion of accuracy in proper perspective. These major considerations are: 1) the measurement system, 2) the assay design and 3) the calculations and statistical control. Such an approach permits an evaluation, both relative and absolute, for a single method or for multiple methods.


1977 ◽  
Vol 182 (2) ◽  
pp. 390-395 ◽  
Author(s):  
John G. Haddad ◽  
Chong Min ◽  
Mike Mendelsohn ◽  
Eduardo Slatopolsky ◽  
Theodore J. Hahn

1976 ◽  
Vol 68 (2) ◽  
pp. 99-105 ◽  
Author(s):  
B. Garcia-Pascual ◽  
A. Peytremann ◽  
B. Courvoisier ◽  
D.E.M. Lawson

Sign in / Sign up

Export Citation Format

Share Document