Partial discharge mechanism in a non-uniform electric field at higher pressure

2011 ◽  
Vol 5 (2) ◽  
pp. 59-66 ◽  
Author(s):  
B. Florkowska ◽  
P. Zydron ◽  
M. Florkowski ◽  
J. Roehrich
2020 ◽  
Vol 27 (4) ◽  
pp. 1119-1127
Author(s):  
Shenyang Mo ◽  
Zhibin Zhao ◽  
Xuebao Li ◽  
Xiang Cui ◽  
Jiayu Xu ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2676 ◽  
Author(s):  
Marek Florkowski ◽  
Dariusz Krześniak ◽  
Maciej Kuniewski ◽  
Paweł Zydroń

This paper describes a correlation of partial discharge phase-resolved patterns with an optical imaging performed in a non-uniform electric field configuration. The influence of different dielectric barrier materials, placed on the plane electrode, on the discharge propagation and surface landing was investigated. The investigations were focused on the corona at positive polarity of AC high voltage. It was found that the initial positive corona stage is similar for all cases whereas the discharge propagation and surface landing strongly depends on the barrier material properties. The observed streamer discharge modes have been described by the geometrical measures such as stem length, stretch of a discharge profile on the dielectric barrier surface and an hemispherical envelope of discharge filaments. Since various dielectrics reveal different properties of charge accumulation and surface neutralization, the charge memory effect may be visible and can be related to the ability to create and sustain of additional electric field component. It may refer to subsequent discharges as well as to conditions faced at the voltage polarity reversal. The correspondence between different forms of phase-resolved patterns have been associated with the modes of streamer discharges observed by optical imaging. Presented methodology poses huge potential for both scientific investigations on underlying discharge phenomena as well as on the application in future diagnostic systems of HV insulation.


Energies ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 4830
Author(s):  
Alper Aydogan ◽  
Fatih Atalar ◽  
Aysel Ersoy Yilmaz ◽  
Pawel Rozga

In high-voltage equipment, it is vital to detect any failure in advance. To do this, a determination of the partial discharges occurring at different voltage types as well as at different electrode configurations is essential for observing the oil condition. In this study, an experimental setup consisting of a needle–semi-sphere electrode configuration immersed in mineral oil is prepared for laboratory experiment. In such a way, a non-uniform electric field is created and the leakage currents are monitored from the grounded electrode. A total of six different electrode configurations are analyzed during the tests by the use of hemispheres of different diameters as grounded electrodes and copper and steel pointed (medical) needle high-voltage electrodes. In the experiments, the partial discharges occurring at four different voltage levels between 5.4 and 10.8 kV are measured and recorded. The effect of the different electrode configurations and voltage levels on the harmonic distortion are noted and discussed. It is experimentally confirmed that it is possible to measure the leakage current caused by the partial discharges of the corona type in oil at the different metal points, creating high-voltage electrodes and different electric field distributions based on the proposed non-invasive measurement technique. The studies showed that there is a significant rise of even harmonic components in the leakage current during the increase in the partial discharge intensity with the 5th harmonic as dominant.


Sign in / Sign up

Export Citation Format

Share Document