scholarly journals Endoscopic ultrasound-guided gastrojejunostomy as a rescue therapy for gastric outlet obstruction in a patient with multiple previous procedures

Endoscopy ◽  
2020 ◽  
Author(s):  
Enrique Pérez-Cuadrado-Robles ◽  
Guillaume Perrod ◽  
Hédi Benosman ◽  
Emilia Ragot ◽  
Claire Gallois ◽  
...  
Endoscopy ◽  
2021 ◽  
Author(s):  
Amanda Marino ◽  
Ali Bessissow ◽  
Corey Miller ◽  
David Valenti ◽  
Louis Boucher ◽  
...  

Abstract Introduction We recently developed a double-balloon device, using widely available existing technology, to facilitate endoscopic ultrasound-guided gastroenterostomy (EUS-GE). Our aim is to assess the feasibility of this modified approach to EUS-guided double-balloon-occluded gastroenterostomy bypass (M-EPASS). Methods This was a single-center retrospective study of consecutive patients undergoing M-EPASS from January 2019 to August 2020. The double-balloon device consists of two vascular balloons that optimize the distension of a targeted small-bowel segment for EUS-guided stent insertion. The primary end point was the rate of technical success. Results 11 patients (45 % women; mean [standard deviation (SD)] age 64.9 [8.6]) with malignant gastric outlet obstruction were included. Technical and clinical success (ability to tolerate an oral diet) were achieved in 91 % (10/11) and 80 % (8/10) of patients, respectively. There was one adverse event (9 %) due to stent migration. Two patients (18 %) required re-intervention for stent obstruction secondary to food impaction. The mean (SD) time to a low residue diet was 3.5 (2.4) days. Conclusion M-EPASS appears to facilitate the technique of EUS-GE, potentially enhancing its safety and clinical adoption. Larger studies are needed to validate this innovative approach to gastric outlet obstruction.


2020 ◽  
Vol 08 (09) ◽  
pp. E1194-E1201 ◽  
Author(s):  
Janine B. Kastelijn ◽  
Leon M.G. Moons ◽  
Francisco J. Garcia-Alonso ◽  
Manuel Pérez-Miranda ◽  
Viliam Masaryk ◽  
...  

Abstract Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) with a lumen-apposing metal stent (LAMS) is a novel, minimally invasive technique in the palliative treatment of malignant gastric outlet obstruction (GOO). Several studies have demonstrated feasibility and safety of EUS-GE, but evidence on long-term durability is limited. The aim of this study was to evaluate patency of EUS-GE in treatment of malignant GOO. Patients and Methods An international multicenter study was performed in seven centers in four European countries. Patients who underwent EUS-GE with a LAMS between March 2015 and March 2019 for palliative treatment of symptomatic malignant GOO were included retrospectively. Our main outcome was recurrent obstruction due to LAMS dysfunction; other outcomes of interest were technical success, clinical success, adverse events (AEs), and survival. Results A total of 45 patients (mean age 69.9 ± 12.3 years and 48.9 % male) were included. Median duration of follow-up was 59 days (interquartile range [IQR] 41–128). Recurrent obstruction occurred in two patients (6.1 %), after 33 and 283 days of follow-up. Technical success was achieved in 39 patients (86.7 %). Clinical success was achieved in 33 patients (73.3 %). AEs occurred in 12 patients (26.7 %), of which five were fatal. Median overall survival was 57 days (IQR 32–114). Conclusions EUS-GE showed a low rate of recurrent obstruction. The relatively high number of fatal AEs underscores the importance of careful implementation of EUS-GE in clinical practice.


Sign in / Sign up

Export Citation Format

Share Document