scholarly journals Patency of endoscopic ultrasound-guided gastroenterostomy in the treatment of malignant gastric outlet obstruction

2020 ◽  
Vol 08 (09) ◽  
pp. E1194-E1201 ◽  
Author(s):  
Janine B. Kastelijn ◽  
Leon M.G. Moons ◽  
Francisco J. Garcia-Alonso ◽  
Manuel Pérez-Miranda ◽  
Viliam Masaryk ◽  
...  

Abstract Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) with a lumen-apposing metal stent (LAMS) is a novel, minimally invasive technique in the palliative treatment of malignant gastric outlet obstruction (GOO). Several studies have demonstrated feasibility and safety of EUS-GE, but evidence on long-term durability is limited. The aim of this study was to evaluate patency of EUS-GE in treatment of malignant GOO. Patients and Methods An international multicenter study was performed in seven centers in four European countries. Patients who underwent EUS-GE with a LAMS between March 2015 and March 2019 for palliative treatment of symptomatic malignant GOO were included retrospectively. Our main outcome was recurrent obstruction due to LAMS dysfunction; other outcomes of interest were technical success, clinical success, adverse events (AEs), and survival. Results A total of 45 patients (mean age 69.9 ± 12.3 years and 48.9 % male) were included. Median duration of follow-up was 59 days (interquartile range [IQR] 41–128). Recurrent obstruction occurred in two patients (6.1 %), after 33 and 283 days of follow-up. Technical success was achieved in 39 patients (86.7 %). Clinical success was achieved in 33 patients (73.3 %). AEs occurred in 12 patients (26.7 %), of which five were fatal. Median overall survival was 57 days (IQR 32–114). Conclusions EUS-GE showed a low rate of recurrent obstruction. The relatively high number of fatal AEs underscores the importance of careful implementation of EUS-GE in clinical practice.

Endoscopy ◽  
2021 ◽  
Author(s):  
Michael Bejjani ◽  
Bachir Ghandour ◽  
Jose Carlos Subtil ◽  
Belén Martínez ◽  
Reem Z Sharaiha ◽  
...  

Background/Aims: The majority of studies on EUS-guided gastroenterostomy (EUS-GE) for palliation of malignant gastric outlet obstruction (GOO) have utilized a 15mm lumen apposing metal stent (LAMS). More recently, a 20mm LAMS has become available. The aim of this study was to compare rates of technical and clinical success, and adverse events (AEs) in patients undergoing EUS-GE using a 20mm vs 15mm LAMS. Methods: Patients who underwent EUS-GE with 15mm or 20mm LAMS for malignant GOO during the period of 1/2018-10/2020 were included. The primary outcome was clinical success, defined as an increase in the gastric outlet obstruction score (GOOS) by at least 1 point during follow-up. Secondary outcomes were technical success, maximum tolerated diet, rate of reintervention, and the rate/severity of AEs. Results: A total of 267 patients (mean age 67yr, F 43%) with malignant GOO from 19 centers underwent EUS-GE. The rate of clinical success was similar between the 15mm and 20mm stents (89.2% [95% CI 84.2-94.2] vs 84.1% [95%CI 77.4-90.6]). However, a significantly higher proportion of patients in the 20mm group tolerated a soft solid/complete diet at the end of follow-up (91.2% [95%CI 84.4-95.7] vs 81.2% [95%CI 73.9-87.2] p=0.04). Overall, AEs occurred in 33 (12.4% [95%CI 8.4-16.3]) patients, with rates being similar between 15mm and 20mm stents (12.8% [95%CI 7.5-18.2] vs 11.8% [95%CI 6-17.6]), including incidence of severe/fatal AEs (2% [95%CI 0.4-5.8] vs 3.4% [95%CI 0.9-8.4]). Conclusions: The 20mm LAMS is similar to the 15mm LAMS in terms of safety and efficacy for patients undergoing EUS-GE for malignant GOO. The 20 mm LAMS allows a more advanced diet and is, thus, the preferred LAMS during EUS-GE.


Endoscopy ◽  
2021 ◽  
Author(s):  
Nam Q. Nguyen ◽  
Christopher M. Hamerski ◽  
Andrew Nett ◽  
Rabindra R. Watson ◽  
Morgan Rigopoulos ◽  
...  

Abstract Background This study evaluated an oroenteric catheter (OEC)-assisted technique to distend the enteric loop for endoscopic ultrasound-guided gastroenterostomy (EUS-GE) in patients with gastric outlet obstruction (GOO). Methods Patient outcomes were reviewed. Proximal enteric loops were filled with water via an OEC (7 Fr or 8 Fr), providing a target for EUS-GE using a lumen-apposing metal stent (15-mm caliber). Clinical success was defined as toleration of a non-liquid diet by Day 3. Results 42 patients (mean age 73.1 [SEM 2.8] years; 23 male) underwent EUS-GE for malignant (n = 37) and benign (n = 5) duodenal strictures. EUS-GE creation was successful in 41/42 (98 %), with mean procedure time of 36 (SEM 3) minutes and no serious complications. Clinical success was achieved in 39/42 (93 %) at 5.7 (SEM 2.6) months’ follow-up. Of 14 patients who died, 13 (93 %) maintained oral intake until death. EUS-GE provided good symptom relief in all 28 surviving patients until follow-up. Conclusions OEC-assisted EUS-GE provided satisfactory relief of GOO symptoms, with high technical success (98 %) and no serious complications.


Endoscopy ◽  
2021 ◽  
Author(s):  
Amanda Marino ◽  
Ali Bessissow ◽  
Corey Miller ◽  
David Valenti ◽  
Louis Boucher ◽  
...  

Abstract Introduction We recently developed a double-balloon device, using widely available existing technology, to facilitate endoscopic ultrasound-guided gastroenterostomy (EUS-GE). Our aim is to assess the feasibility of this modified approach to EUS-guided double-balloon-occluded gastroenterostomy bypass (M-EPASS). Methods This was a single-center retrospective study of consecutive patients undergoing M-EPASS from January 2019 to August 2020. The double-balloon device consists of two vascular balloons that optimize the distension of a targeted small-bowel segment for EUS-guided stent insertion. The primary end point was the rate of technical success. Results 11 patients (45 % women; mean [standard deviation (SD)] age 64.9 [8.6]) with malignant gastric outlet obstruction were included. Technical and clinical success (ability to tolerate an oral diet) were achieved in 91 % (10/11) and 80 % (8/10) of patients, respectively. There was one adverse event (9 %) due to stent migration. Two patients (18 %) required re-intervention for stent obstruction secondary to food impaction. The mean (SD) time to a low residue diet was 3.5 (2.4) days. Conclusion M-EPASS appears to facilitate the technique of EUS-GE, potentially enhancing its safety and clinical adoption. Larger studies are needed to validate this innovative approach to gastric outlet obstruction.


2019 ◽  
Vol 07 (11) ◽  
pp. E1474-E1482 ◽  
Author(s):  
Thomas R. McCarty ◽  
Rajat Garg ◽  
Christopher C. Thompson ◽  
Tarun Rustagi

Abstract Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is a novel endoscopic procedure designed to facilitate sustained luminal patency in patients with gastric outlet obstruction. The primary aim of this study was to evaluate the efficacy and safety of EUS-GE for treatment of gastric outlet obstruction. Methods Searches of PubMed, EMBASE, Web of Science, and Cochrane Library databases were performed through April 2019. Patients with benign and malignant gastric outlet obstruction were included. Measured outcomes included: immediate technical and clinical success as well as rate of serious adverse events (AEs). Heterogeneity was assessed with Cochran Q test and I 2 statistics. Publication bias was ascertained by funnel plot and Egger regression testing. Results A total of five studies (n = 199 patients; 45.73 % male) were included in this study. Four retrospective studies and one prospective study were analyzed. Mean age of patients that underwent the EUS-GE procedure was 64.52 ± 1.37 years with a pooled mean follow-up period of 4.32 ± 1.65 months. In 21 % of patients (n = 43), gastric outlet obstruction was due to benign causes. Immediate technical success was 92.90 % (95 % CI; 88.26 – 95.79; I2 = 0.00 %) and reported in all studies. The clinical success rate of EUS-GE was 90.11 % (95 % CI; 84.64 – 93.44; I2 = 0.00 %). Serious AEs occurred in 5.61 % (95 % CI; 2.87 – 10.67; I2 = 1.67 %) of cases and were related to peritonitis, perforation, bleeding, and abdominal pain. Re-intervention rate was 11.43 % (95 % CI; 7.29 – 17.46; I2 = 17.38 %). Conclusions EUS-GE appears to provide an effective and safe minimally invasive alternative for treatment of benign and malignant gastric outlet obstruction.


2021 ◽  
Vol 09 (06) ◽  
pp. E895-E900
Author(s):  
Zain A. Sobani ◽  
Swathi Paleti ◽  
Tarun Rustagi

Abstract Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using a 15-mm lumen apposing metal stent (LAMS) has emerged as a viable alternative to surgical gastrojejunostomy for management of gastric outlet obstruction (GOO). However, given the size of the anastomosis created with a 15-mm LAMS, long-term luminal patency and clinical outcomes may be suboptimal. The aim of this study was to evaluate the technical feasibility, efficacy, and safety of EUS-GE with a large-diameter (20 mm) LAMS (LLAMS). Patients and methods A retrospective analysis of a prospectively maintained database of all patients undergoing EUS-GE with LLAMS between December 1, 2018 and September 30, 2020 was performed. All EUS-GEs were performed using a cautery-enhanced LLAMS. Results Thirty-three patients were referred for endoscopic management of GOO. Two patients were excluded due to a lack of an adequate window for EUS-GE. The remaining 31 patients (93.94 %) (mean age: 61.35 ± 16.52 years; 54.84 % males) underwent EUS-GE using LLAMS for malignant (n = 23) and benign (n = 8) GOO. Technical success was achieved in all patients (100 %) with attempted EUS-GE. Complete clinical success (tolerance of regular diet) was achieved in 93.55 % of patients (n = 29). Two patients (6.45 %) had partial clinical success and died of unrelated causes prior to advancing diet beyond full liquids. Overall mean follow-up was 140.84 ± 160.41 days (median 70, range 4–590). All stents remained patent with no evidence of recurrent GOO symptoms. One patient (3.23 %) developed an asymptomatic clean-based jejunal ulcer on 3-month follow-up endoscopy. Conclusions EUS-GE with LLAMS is a technically feasible, effective and safe option for patients with GOO allowing for tolerability of regular diet. Future prospective, ideally randomized studies comparing long-term outcomes of EUS-GE with 20- and 15-mm LAMS are required.


2021 ◽  
Vol 09 (12) ◽  
pp. E1918-E1923
Author(s):  
Jahangeer Basha ◽  
Sundeep Lakhtakia ◽  
Raghavendra Yarlagadda ◽  
Zaheer Nabi ◽  
Rajesh Gupta ◽  
...  

Abstract Background and study aims Endoscopic ultrasound-guided gastro-enterostomy(EUS-GE) is a recently described novel minimally invasive endoscopic procedure for patients having malignant gastric outlet obstruction (GOO). The safety of EUS-GE in the presence of ascites with GOO is not known. The objective of the study was to evaluate the feasibility and safety of EUS-GE in patients with GOO and ascites. Patients and methods Consecutive patients with GOO who underwent EUS-GE between January 2019 and March 2021 constituted the study population. EUS-GE was performed using either EPASS or free-hand technique. The technical success, clinical success, adverse events, and survival times were evaluated. The outcomes were compared between patients with and without ascites. Results A total of 31 patients with GOO underwent EUS-GE of whom 29 (93.5 %) had malignant and two (6.4 %) had benign etiologies. Ascites was observed in 12 out of 31 (38.7%) patients and all had underlying malignancy. Majority (27, 87 %) of the EUS-GE procedures were performed using EPASS technique, and 4 (13 %) underwent free-hand technique. Eleven of 12 patients with ascites and GOO underwent EUS GE using EPASS technique. The technical success (91.6 % vs. 89.4 %; P = 0.841), clinical success (83.3 % vs. 89.4 %; P = 0.619), mean procedure time (32 vs. 31.6 min; P = 0.968) and adverse events (0 % vs. 10.5 %; P = 0.245) were not significantly different between patients with or without ascites. However, the median survival time was significantly low in patients with ascites when compared to without ascites (36 vs. 290 days; P < 001). Conclusions Ascites is a common occurrence in patients with malignant GOO. EUS GE is feasible in presence of ascites with EPASS technique.


2019 ◽  
Vol 07 (02) ◽  
pp. E144-E150 ◽  
Author(s):  
Tossapol Kerdsirichairat ◽  
Shayan Irani ◽  
Juliana Yang ◽  
Olaya Brewer Gutierrez ◽  
Robert Moran ◽  
...  

Abstract Background and study aims EUS-guided gastroenterostomy (GE) is a novel, minimally invasive endoscopic procedure for the treatment of gastric outlet obstruction (GOO). The direct-EUS-GE (D-GE) approach has recently gained traction. We aimed to report on a large cohort of patients who underwent DGE with focus on long-term outcomes. Patients and methods This two-center, retrospective study involved consecutive patients who underwent D-GE between October 2014 and May 2018. The primary outcomes were technical and clinical success. Secondary outcomes were adverse events (AEs), rate of reintervention, procedure time, time to resume oral diet, and post-procedure length of stay (LOS). Results A total of 57 patients (50.9 % female; median age 65 years) underwent D-GE for GOO. The etiology was malignant in 84.2 % and benign in 15.8 %. Technical success and clinical success were achieved in 93 % and 89.5 % of patients, respectively, with a median follow-up of 196 days in malignant GOO and 319.5 days in benign GOO. There were 2 (3.5 %) AEs, one severe and one moderate. Median procedure time was 39 minutes (IQR, 26 – 51.5 minutes). Median time to resume oral diet after D-GE was 1 day (IQR 1 – 2 days). Median post D-GE LOS was 3 days (IQR 2 – 7 days). Rate of reintervention was 15.1 %. Conclusions D-GE is safe and effective in management of both malignant and benign causes of GOO. Clinical success with D-GE is durable with a low rate of reintervention based on a long-term cohort.


Sign in / Sign up

Export Citation Format

Share Document