scholarly journals Water-filled technique for therapeutic pancreato-biliary EUS in patients with surgically altered anatomy

2021 ◽  
Vol 09 (03) ◽  
pp. E487-E489
Author(s):  
Benedetto Mangiavillano ◽  
Silvia Carrara ◽  
Leonardo H. Eusebi ◽  
Franceasco Auriemma ◽  
Mario Bianchetti ◽  
...  

AbstractOne of the main challenges encountered by endosonographers is performing diagnostic and interventional pancreato-biliary endoscopic ultrasound (EUS) procedures in the presence of surgically altered upper gastrointestinal anatomy. We describe the water-filled technique (WFT) for EUS examination and treatment of the pancreato-biliary region in patients with surgically altered upper gastrointestinal anatomy. Using the WFT, the scope is advanced up to the gastro-jejunal anastomosis and, after placing the tip of the scope 2 cm beyond it, enlargement of the jejunal lumen is obtained by water instillation of the jejunal loop. An enlargement of more than 1.5 cm allows advancement of the tip of the scope under EUSguidance up to the duodenum, in a retrograde way. The WFT is useful for reaching the ampullary area and performing diagnostic and therapeutic EUS in patients with surgically altered anatomy. The technique is also reproducible and can be easily used by endoscopists who regularly perform EUS.

2002 ◽  
Vol 32 (8) ◽  
pp. 372-378 ◽  
Author(s):  
A. J. Kaffes ◽  
A. Mishra ◽  
S. B. Simpson ◽  
D. B. Jones

2021 ◽  
Vol 12 (4) ◽  
pp. 405-422
Author(s):  
Ting-Ting Chan ◽  
Marcus C. H. Chew ◽  
Raymond S. Y. Tang

Despite experienced hands and availability of various well-designed catheters and wires, selective bile duct cannulation may still fail in 10–20% of cases during endoscopic retrograde cholangiopancreatography (ERCP). In case standard ERCP cannulation technique fails, salvage options include advanced ERCP cannulation techniques such as double-guidewire technique (DGW) with or without pancreatic stenting and precut papillotomy, percutaneous biliary drainage (PBD), and endoscopic ultrasound-guided Rendezvous (EUS-RV) ERCP. If the pancreatic duct is inadvertently entered during cannulation attempts, DGW technique is a reasonable next step, which can be followed by pancreatic stenting to reduce risks of post-ERCP pancreatitis (PEP). Studies suggest that early precut papillotomy is not associated with a higher risk of PEP, while needle-knife fistulotomy is the preferred method. For patients with critical clinical condition who may not be fit for endoscopy, surgically altered anatomy in which endoscopic biliary drainage is not feasible, and non-communicating multisegmental biliary obstruction, PBD has a unique role to provide successful biliary drainage efficiently in this particular population. As endoscopic ultrasound (EUS)-guided biliary drainage techniques advance, EUS-RV ERCP has been increasingly employed to guide bile duct access and cannulation with satisfactory clinical outcomes and is especially valuable for benign pathology at centres where expertise is available. Endoscopists should become familiar with each technique’s advantages and limitations before deciding the most appropriate treatment that is tailored to patient’s anatomy and clinical needs.


2011 ◽  
Vol 25 (11) ◽  
pp. 615-619 ◽  
Author(s):  
S Cho ◽  
P Kamalaporn ◽  
G Kandel ◽  
P Kortan ◽  
N Marcon ◽  
...  

BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) remains a challenge for endoscopists in patients with surgically altered anatomy of the upper gastrointestinal tract. Double-balloon enteroscopes (DBEs) have revolutionized the ability to access the small bowel. The indication for its therapeutic use is expanding to include ERCP for patients who have undergone small bowel reconstruction. Most of the published experiences in DBE-assisted ERCP have used conventional double-balloon enteroscopes that are 200 cm in length, which do not permit use of the standard ERCP accessories. The authors report their experience with DBE-assisted ERCP using a ‘short’ DBE in patients with surgically altered anatomy.METHODS: A retrospective review of patients with previous small bowel reconstruction who underwent ERCP with a ‘short’ DBE at the Centre for Therapeutic Endoscopy and Endoscopic Oncology (Toronto, Ontario) between February 2007 and November 2008 was performed.RESULTS: A total of 20 patients (10 men) with a mean age of 57.9 years (range 26 to 85 years) underwent 29 sessions of ERCP with a DBE. Six patients underwent Billroth II gastroenterostomy, seven patients Roux-en-Y hepaticojejunostomy, five patients Roux-en-Y gastrojejunostomy, one patient Roux-en-Y esophagojejunostomy and one patient a Whipple’s operation with choledochojejunostomy. Some patients (n=12 [60%]) underwent previous attempts at ERCP in which the papilla of Vater or bilioenteric anastomosis could not be reached with either a duodenoscope or pediatric colonoscope. All procedures were performed with a commercially available DBE (working length 152 cm, distal end diameter 9.4 mm, channel diameter 2.8 mm). The procedures were performed under conscious sedation with intravenous midazolam, fentanyl and diazepam, except in one patient in whom general anesthesia was administered. Either the papilla of Vater or bilioenteric anastomosis was reached in 25 of 29 cases (86.2%) in a mean duration of 20.8 min (range 5 min to 82 min). Bile duct cannulation was successful in 24 of 25 cases in which the papilla or bilioenteric anastomosis was reached. Therapeutic interventions were successful in 15 patients (24 procedures) including sphincterotomy (n=7), stone extraction (n=9), biliary dilation (n=8), stent placement (n=9) and stent removal (n=8). The mean total duration of the procedures was 70.7 min (range 30 min to 117 min). There were no procedure-related complications.CONCLUSION: DBEs enable successful diagnostic and therapeutic ERCP in patients with a surgically altered anatomy of the upper gastrointestinal tract. It is a safe, feasible and less invasive therapeutic option in this group of patients. Standard ‘long’ DBEs have limitations of long working length and the need for modified ERCP accessories. ‘Short’ DBEs are equally as effective in reaching the target limb as standard ‘long’ DBEs, and overcomes some limitations of long DBEs to result in high success rates for endoscopic therapy.


2011 ◽  
Vol 26 (12) ◽  
pp. 1717-1720
Author(s):  
Shinpei Doi ◽  
Ichiro Yasuda ◽  
Masanori Nakashima ◽  
Junji Kawaguchi ◽  
Takahiro Yamauchi ◽  
...  

Endoscopy ◽  
2016 ◽  
Vol 48 (S 01) ◽  
pp. E263-E264 ◽  
Author(s):  
Sudipta Chowdhury ◽  
Reuben Kurien ◽  
A. Bharath ◽  
Amit Dutta ◽  
Deepu David ◽  
...  

2008 ◽  
Vol 67 (5) ◽  
pp. AB201
Author(s):  
Ryoji Miyahara ◽  
Yasumasa Niwa ◽  
Masanao Nakamura ◽  
Yoichi Iguchi ◽  
Yoshiko Kodama ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document