scholarly journals Jejunostomy tube removed after pancreaticoduodenectomy using single-balloon endoscopy

Endoscopy ◽  
2021 ◽  
Author(s):  
Keiichi Haga ◽  
Tomoyoshi Shibuya ◽  
Kei Nomura ◽  
Mayuko Haraikawa ◽  
Osamu Nomura ◽  
...  
Endoscopy ◽  
2017 ◽  
Vol 49 (10) ◽  
pp. E234-E236
Author(s):  
Alvaro Martínez-Alcalá ◽  
Marco D’Assunção ◽  
Thomas Kröner ◽  
Lucia Fry ◽  
Ivan Jovanovic ◽  
...  

Endoscopy ◽  
2021 ◽  
Author(s):  
Shaopeng Liu ◽  
Tao Dong ◽  
Yupeng Shi ◽  
Hui Luo ◽  
Xianmin Xue ◽  
...  

<b>Background and study aims</b> Single-balloon enteroscopy (SBE) is a valuable but difficult modality for the diagnosis and treatment of small-bowel diseases. The water exchange (WE) method has the advantage of facilitating intubation during colonoscopy. Here, we evaluated the effects of WE on procedure-related variables related to SBE. <b>Patients and methods</b> This randomized controlled trial was conducted in a tertiary-care referral center in China. Patients with attempt at total enteroscopy (ATE) were randomly allocated to undergo WE-assisted (WE group) or carbon dioxide-insufflated enteroscopy (CO<sub>2</sub> group). All patients were planned to undergo both antegrade and retrograde procedures. The primary outcome was the total enteroscopy rate (TER). Secondary outcomes included maximal insertion depth, positive findings, procedural time and adverse events. <b>Results</b> In total, 110 patients were enrolled, with 55 in each group. Baseline characteristics between the two groups were comparable. TER was achieved in 58.2% (32/55) of the WE group and 36.4% (20/55) of the control group (p=0.022). The estimated intubation depth was 521.2±101.4 cm in the WE group and 481.6±95.2 cm in the CO<sub>2</sub> group (p=0.037). The insertion time was prolonged in the WE group compared with CO<sub>2</sub> group (178.9±45.1 min vs. 154.2±27.6 min, p<0.001). Endoscopic findings and adverse events were comparable between the two groups. <b>Conclusions</b> The WE method improved TER and increased intubation depth during SBE. The use of WE did not increase complications of enteroscopy. Clinical trial registation: https://clinicaltrials.gov/, NCT01942863.


2010 ◽  
Vol 2010 ◽  
pp. 1-3 ◽  
Author(s):  
Marta Di Pisa ◽  
Roberto Miraglia ◽  
Riccardo Volpes ◽  
Salvatore Gruttadauria ◽  
Mario Traina

We report a case of a post-transplant patient with hepaticojejunostomy in whom we used a single balloon enteroscopy to access the biliary tree. This procedure seems to be safe and feasible for approaching the biliary anastomosis by means of the overtube and fixation of the small bowel by the balloon.


Sign in / Sign up