The effects of anaemia and red blood cell transfusion on cerebral oxygenation in neonates as measured by near-infrared spectroscopy (NIRS)

2008 ◽  
Vol 212 (S 1) ◽  
Author(s):  
SJ Arri ◽  
J Ersch ◽  
T Mühlemann ◽  
D Haensse ◽  
JC Fauchére ◽  
...  
2017 ◽  
Vol 34 (17) ◽  
pp. 2553-2559 ◽  
Author(s):  
Santiago R. Leal-Noval ◽  
Victoria Arellano-Orden ◽  
Manuel Muñoz-Gómez ◽  
Aurelio Cayuela ◽  
Antonio Marín-Caballos ◽  
...  

2014 ◽  
Vol 22 (6) ◽  
pp. 375-388 ◽  
Author(s):  
Beena G. Sood ◽  
Josef Cortez ◽  
Kathleen McLaughlin ◽  
Meenakshi Gupta ◽  
Arun Amaram ◽  
...  

2017 ◽  
Vol 34 (08) ◽  
pp. 735-741 ◽  
Author(s):  
Farha Vora ◽  
Judy Gates ◽  
Kimberley Gerard ◽  
Shawn Hanson ◽  
Richard Applegate ◽  
...  

Abstract Objectives There are no widely accepted methods of continuously monitoring gut oxygenation in the newborn during packed red blood cell transfusion. We investigated the use of an orally inserted light spectroscopy probe to measure lower esophageal oxyhemoglobin saturations (eStO2) before, during, and after transfusion and made comparisons with abdominal near-infrared spectroscopy (NIRS) and superior mesenteric artery (SMA) flow. Study Design Thirteen neonates with corrected gestational ages ranging from 22 weeks, 0 day to 37 weeks, 5 days were enrolled. eStO2 and NIRS measurements were recorded continuously for a 25-hour period starting 1 hour prior to starting the 4-hour transfusion. Transabdominal ultrasound was used to measure SMA flow prior to, upon completion, and 20 hours after the transfusion. Results Twelve infants completed the study. eStO2 was well-tolerated and was weakly (r = 0.06) correlated (p < 0.001) with NIRS. Compared with NIRS, eStO2 demonstrated a markedly greater variation in oxyhemoglobin values. NIRS and SMA flow measurements did not change, while eStO2 increased from 48 ± 5% and 45 ± 5% in the pre- and intratransfusion periods to 57 ± 4% in the posttransfusion period (p = 0.03). Conclusion Measurement of eStO2 is feasible in neonates and may provide a continuous and sensitive index of rapid changes in mesenteric oxygenation in this patient population.


1999 ◽  
Vol 88 (3) ◽  
pp. 554-558 ◽  
Author(s):  
A. Timothy Lovell ◽  
Huw Owen-Reece ◽  
Clare E. Elwell ◽  
Martin Smith ◽  
John C. Goldstone

2006 ◽  
Vol 59 (3) ◽  
pp. 462-465 ◽  
Author(s):  
Nicole Nagdyman ◽  
Thilo Fleck ◽  
Birgit Bitterling ◽  
Peter Ewert ◽  
Hashim Abdul-Khaliq ◽  
...  

Neonatology ◽  
2021 ◽  
pp. 1-6
Author(s):  
Bi Ze ◽  
Lili Liu ◽  
Ge Sang Yang Jin ◽  
Minna Shan ◽  
Yuehang Geng ◽  
...  

<b><i>Background:</i></b> Accurate detection of cerebral oxygen saturation (rSO<sub>2</sub>) may be useful for neonatal brain injury prevention, and the normal range of rSO<sub>2</sub> of neonates at high altitude remained unclear. <b><i>Objective:</i></b> To compare cerebral rSO<sub>2</sub> and cerebral fractional tissue oxygen extraction (cFTOE) at high-altitude and low-altitude areas in healthy neonates and neonates with underlying diseases. <b><i>Methods:</i></b> 515 neonates from low-altitude areas and 151 from Tibet were enrolled. These neonates were assigned into the normal group, hypoxic-ischemic encephalopathy (HIE) group, and other diseases group. Near-infrared spectroscopy was used to measure rSO<sub>2</sub> in neonates within 24 h after admission. The differences of rSO<sub>2</sub>, pulse oxygen saturation (SpO<sub>2</sub>), and cFTOE levels were compared between neonates from low- and high-altitude areas. <b><i>Results:</i></b> (1) The mean rSO<sub>2</sub> and cFTOE levels in normal neonates from Tibet were 55.0 ± 6.4% and 32.6 ± 8.5%, significantly lower than those from low-altitude areas (<i>p</i> &#x3c; 0.05). (2) At high altitude, neonates with HIE, pneumonia (<i>p</i> &#x3c; 0.05), anemia, and congenital heart disease (<i>p</i> &#x3c; 0.05) have higher cFTOE than healthy neonates. (3) Compared with HIE neonates from plain areas, neonates with HIE at higher altitude had lower cFTOE (<i>p</i> &#x3c; 0.05), while neonates with heart disease in plateau areas had higher cFTOE than those in plain areas (<i>p</i> &#x3c; 0.05). <b><i>Conclusions:</i></b> The rSO<sub>2</sub> and cFTOE levels in normal neonates from high-altitude areas are lower than neonates from the low-altitude areas. Lower cFTOE is possibly because of an increase in blood flow to the brain, and this may be adversely affected by disease states which may increase the risk of brain injury.


Sign in / Sign up

Export Citation Format

Share Document