Infrastructure Risk Analysis of Municipal Water Distribution System

2000 ◽  
Vol 6 (3) ◽  
pp. 118-122 ◽  
Author(s):  
Barry C. Ezell ◽  
John V. Farr ◽  
Ian Wiese
2015 ◽  
Vol 42 (4) ◽  
pp. 250-258 ◽  
Author(s):  
Megan J. Liu ◽  
Stephen Craik ◽  
David Z. Zhu

Predicting disinfectant concentrations in water distribution systems using water quality models requires the input of the wall decay coefficient of the disinfectant. In this study, field water sampling data was integrated with network hydraulic and water quality model simulations of a section of the municipal water distribution system in the City of Edmonton, composed of predominantly cast iron piping, to determine a wall decay coefficient for combined chlorine (chloramine). Unique combined chlorine wall decay coefficients that provided the best fit of model-predicted chlorine concentrations to the field data were determined at two temperatures. Using the determined wall decay coefficients, the water quality model can be used to predict combined chlorine concentrations.


2009 ◽  
Vol 137 (12) ◽  
pp. 1713-1720 ◽  
Author(s):  
D. WERBER ◽  
D. LAUŠEVIĆ ◽  
B. MUGOŠA ◽  
Z. VRATNICA ◽  
L. IVANOVIĆ-NIKOLIĆ ◽  
...  

SUMMARYOn 24 August 2008, an outbreak alert regarding cases of acute gastroenteritis in Podgorica triggered investigations to guide control measures. From 23 August to 7 September, 1699 cases were reported in Podgorica (population 136 000) and we estimated the total size of the outbreak to be 10 000–15 000 corresponding to an attack rate of ~10%. We conducted an age- and neighbourhood-matched case-control study, microbiologically analysed faecal and municipal water samples and assessed the water distribution system. All cases (83/83) and 90% (89/90) of controls drank unboiled chlorinated municipal water [matched odds ratio (mOR) 11·2, 95% confidence interval (CI), 1·6–∞]. Consumption of bottled water was inversely associated with illness (mOR 0·3, 95% CI 0·1–0·8). Analyses of faecal samples identified six norovirus genotypes (21/38 samples) and occasionally other viruses. Multiple defects in the water distribution system were noted. These results suggest that the outbreak was caused by faecally contaminated municipal water. It is unusual to have such a large outbreak in a European city especially when the municipal water supply is chlorinated. Therefore, it is important to establish effective multiple-barrier water-treatment systems whenever possible, but even with an established chlorinated supply, sustained vigilance is central to public health.


2013 ◽  
Vol 441 ◽  
pp. 1093-1096
Author(s):  
Wen Zeng ◽  
Yong Ting Pan ◽  
Hong Mei Huang

Scientific analysis of the leakage of the water distribution system in city is very helpful to water supply network’s maintenance and renovation, and hence reduces negative social effect and economic loss. A leakage risk nalysis model for water distribution system was established based on fuzzy analytical hierarchy process (FAHP) and BP neural network (BPNN). This model introduces FAHP to reasonably ensure initial state of BP neural network, and uses weighted superposition to mend learning sample set of BP neural network. The water distribution system of a city in Zhejiang province P. R. China was selected to test the proposed risk analysis model, which verifise its feasibility and effectivity.


2015 ◽  
Vol 119 ◽  
pp. 660-668 ◽  
Author(s):  
Sanda-Carmen Georgescu ◽  
Andrei-Mugur Georgescu ◽  
Remus Alexandru Madularea ◽  
Vlad-Florin Piraianu ◽  
Anton Anton ◽  
...  