A mechanism of deformation and recrystallization texture changes in grain‐oriented silicon steel sheets

1987 ◽  
Vol 61 (8) ◽  
pp. 3853-3855
Author(s):  
Zhen‐Chuan Li ◽  
Qi‐Chun Lü ◽  
Zhong‐Zhi He
2005 ◽  
Vol 495-497 ◽  
pp. 435-440
Author(s):  
Y.H. Sha ◽  
S.C. Zhou ◽  
Z.K. Zou ◽  
X. Zhao ◽  
Liang Zuo

Fe-3.10%Si thin strips were prepared by symmetric and asymmetric cold rolling from commercial grain oriented silicon steel sheets, then annealed with and without a magnetic field. Magnetic field of 12T was applied along the rolling direction. Magnetic annealing does not essentially change the texture development that recrystallization texture consists mainly of η fiber (RD//<001>), and the strongest component tends to transform from Goss ({110}<001>) to {210}<001> with the increase in speed ratio and annealing temperature. But magnetic annealing promotes Goss component in the strips rolled with small speed ratios, while decreases {210 <001> component in those rolled with large speed ratios. Possible effect mechanism of magnetic annealing was discussed.


1999 ◽  
Vol 35 (5) ◽  
pp. 3373-3375 ◽  
Author(s):  
K.N. Chai ◽  
N.H. Heo ◽  
J.G. Na ◽  
H.-T. Jeong ◽  
S.R. Lee

2020 ◽  
Vol 14 (3) ◽  
pp. 242-249
Author(s):  
Fabian Müller ◽  
Gregor Bavendiek ◽  
Nora Leuning ◽  
Benedikt Schauerte ◽  
Kay Hameyer

Sensors ◽  
2019 ◽  
Vol 19 (23) ◽  
pp. 5105
Author(s):  
Chen ◽  
Lin ◽  
Chang ◽  
Cheng ◽  
Chen ◽  
...  

In this paper, we demonstrate an innovative electromagnetic targeting system utilizing a passive magnetic-flux-concentrator for tracking endobronchoscope used in the diagnosis process of lung cancer tumors/lesions. The system consists of a magnetic-flux emitting coil, a magnetic-flux receiving electromagnets-array, and high permeability silicon-steel sheets rolled as a collar (as the passive magnetic-flux-concentrator) fixed in a guide sheath of an endobronchoscope. The emitting coil is used to produce AC magnetic-flux, which is consequently received by the receiving electromagnets-array. Due to the electromagnetic-induction, a voltage is induced in the receiving electromagnets-array. When the endobronchoscope’s guide sheath (with the silicon-steel collar) travels between the emitting coil and the receiving electromagnets-arrays, the magnetic flux is concentrated by the silicon-steel collar and thereby the induced voltage is changed. Through analyzing the voltage–pattern change, the location of the silicon–steel collar with the guide sheath is targeted. For testing, a bronchial-tree model for training medical doctors and operators is used to test our system. According to experimental results, the system is successfully verified to be able to target the endobronchoscope in the bronchial-tree model. The targeting errors on the x-, y- and z-axes are 9 mm, 10 mm, and 5 mm, respectively.


Sign in / Sign up

Export Citation Format

Share Document