AN ANALYSIS OF FLOW FILM BOILING OVER AN INCLINED SURFACE EMBEDDED IN POROUS MEDIA

1995 ◽  
Vol 137 (1) ◽  
pp. 119-133 ◽  
Author(s):  
E. BIGZADEH ◽  
J. OROZCO
Author(s):  
A. A. Avramenko ◽  
Igor V. Shevchuk ◽  
M. M. Kovetskaya ◽  
Y. Y. Kovetska

A correction to this paper has been published: https://doi.org/10.1007/s11242-021-01631-0


2001 ◽  
Author(s):  
C. Frepoli ◽  
A. J. Ireland ◽  
L. E. Hochreiter ◽  
F. B. Cheung

Abstract The droplet injection experiments to be performed in a 7 × 7 rod bundle heat transfer test facility are being simulated using an advanced thermal hydraulics computer code called COBRA-TF. A current version of the code, which provides a three-dimensional, two-fluid, three-field representation of the two-phase flow, is modified to facilitate the simulation of the droplet field produced by the injection system in the test facility. The liquid phase is split into a continuous liquid field and droplet field where a separate momentum and mass equation is solved for each field, with the effects of spacer grids being properly accounted for. Pre-test analyses using the modified COBRA-TF code have been conducted for different injection conditions. Results indicate that there are specific ranges of conditions that can be simulated within the facility constraints to provide for validation of the dispersed flow film boiling models. The numerical results also show important effects of the spacer grids on the local heat transfer in the dispersed flow film boiling regime.


1969 ◽  
Author(s):  
S.J. Hynek ◽  
W.M. Rohsenow ◽  
A.E. Bergles

1990 ◽  
Vol 112 (2) ◽  
pp. 465-471 ◽  
Author(s):  
K. H. Chang ◽  
L. C. Witte

Liquid-solid contacts were measured for flow film boiling of subcooled Freon-11 over an electrically heated cylinder equipped with a surface microthermocouple probe. No systematic variation of the extent of liquid-solid contact with wall superheat, liquid subcooling, or velocity was detected. Only random small-scale contacts that contribute negligibly to overall heat transfer were detected when the surface was above the homogeneous nucleation temperature of the Freon-11. When large-scale contacts were detected, they led to an unexpected intermediate transition from local film boiling to local transition boiling. An explanation is proposed for these unexpected transitions. A comparison of analytical results that used experimentally determined liquid-solid contact parameters to experimental heat fluxes did not show good agreement. It was concluded that the available model for heat transfer accounting for liquid-solid contact is not adequate for flow film boiling.


Sign in / Sign up

Export Citation Format

Share Document